MAURY USCG vessel records
← All vessels

POINTER

POINTER is a 1934 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 14 May 2026.

Built
1934
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH4589
Flag
UNITED STATES
Maury page id
psix-75807

Documentation record

Registered dimensions (L × B × D)34.0 ft × 10.0 ft × 4.5 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWIINIKKA BROTHERS · CHASSELL, MI, UNITED STATES · built 1934
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHARBOR SPRINGS, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

14 May 2026 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383444
13 August 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8208397
12 May 2025 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8133395
16 April 2024 Examination of Repairs · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7913303
17 May 2023 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7690245
22 June 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7484323
19 May 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7211637
17 August 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7037390
24 May 2019 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6692531
30 January 2019 Examination of Repairs · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6621256
23 August 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6520962
21 August 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6519145
15 August 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6248015
29 June 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6016782

Deficiency record · 14

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2024 Resolved
Forward bilge alarm is inoperative, repair or replace and demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2024
Resolved 28 May 2024
Resolution: corrected, replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 April 2024 Resolved
Sink intake valve body is cracked, must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024
Resolved 13 May 2024
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 19 May 2021 Resolved
Drill logs need description and brief scenario, and lessons learned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2021 Resolved
New ring bouy needs retro. Corrected on the spot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 August 2020 Resolved
Hull sheathing on the bow at approximately the waterline has a 1 inch by 2 inch section which has been damaged/sheared off, complete permanent repairs prior to launch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2021
Resolved 19 May 2021
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 June 2019 Resolved
Provide 2 flashlights at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 7 June 2019
Resolution: Owner added 2 flashlights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2019 Resolved
Ensure first aid kid contains all required equipment as per 160.041 and ensure no expired medication is on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 11 June 2019
Resolution: Owner purchased new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019 Resolved
Replace waterlight battery
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 11 June 2019
Resolution: Owner replaced battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2018 Resolved
Repair or replace engine raw water cooling pump. bearings excessively worn, failure imminent.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: pump replaced, witnessed MDE run at idle and throttled up, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2018 Resolved
Propulsion engine jacket water cooling hose deteriorated and leaking at main cooler. Must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: Hose replaced, witnessed MDE run at idle and throttled up, no leaks sighted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2018 Resolved
Drive belts for alternator and raw water pump excessively loose and must be corrected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: Drive belts tightened satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2018 Resolved
Bilge contains excessive oily water, to be pumped and kept dry per stability letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: Bilges pumped, recommended cleaning them as well.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 15 August 2017 Resolved
Make repairs to main engine drive coupling and demonstrate proper operation of same, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 16 August 2017
Resolution: witnessed proper operation
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 15 August 2017 Resolved
Repair and demonstrate proper operation of fire damper for engine enclosure, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 16 August 2017
Resolution: witnessed proper operation.

Ownership record