Records from 2016 to 2026. Most recent: inspection, 14 May 2026.
Documentation record
Registered dimensions (L × B × D)34.0 ft × 10.0 ft × 4.5 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWIINIKKA BROTHERS · CHASSELL, MI, UNITED STATES · built 1934
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHARBOR SPRINGS, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
14 May 2026
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383444
13 August 2025
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8208397
12 May 2025
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8133395
16 April 2024
Examination of Repairs · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7913303
17 May 2023
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7690245
22 June 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7484323
19 May 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7211637
17 August 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7037390
24 May 2019
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6692531
30 January 2019
Examination of Repairs · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6621256
23 August 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6520962
21 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6519145
15 August 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6248015
29 June 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6016782
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2024
Resolved
Forward bilge alarm is inoperative, repair or replace and demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2024
Resolved 28 May 2024
Resolution: corrected, replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 April 2024
Resolved
Sink intake valve body is cracked, must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2024
Resolved 13 May 2024
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 19 May 2021
Resolved
Drill logs need description and brief scenario, and lessons learned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2021
Resolved
New ring bouy needs retro. Corrected on the spot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 August 2020
Resolved
Hull sheathing on the bow at approximately the waterline has a 1 inch by 2 inch section which has been damaged/sheared off, complete permanent repairs prior to launch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2021
Resolved 19 May 2021
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 June 2019
Resolved
Provide 2 flashlights at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 7 June 2019
Resolution: Owner added 2 flashlights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2019
Resolved
Ensure first aid kid contains all required equipment as per 160.041 and ensure no expired medication is on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 11 June 2019
Resolution: Owner purchased new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019
Resolved
Replace waterlight battery
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 11 June 2019
Resolution: Owner replaced battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2018
Resolved
Repair or replace engine raw water cooling pump. bearings excessively worn, failure imminent.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: pump replaced, witnessed MDE run at idle and throttled up, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2018
Resolved
Propulsion engine jacket water cooling hose deteriorated and leaking at main cooler. Must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: Hose replaced, witnessed MDE run at idle and throttled up, no leaks sighted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2018
Resolved
Drive belts for alternator and raw water pump excessively loose and must be corrected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: Drive belts tightened satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2018
Resolved
Bilge contains excessive oily water, to be pumped and kept dry per stability letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2018
Resolved 23 August 2018
Resolution: Bilges pumped, recommended cleaning them as well.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 15 August 2017
Resolved
Make repairs to main engine drive coupling and demonstrate proper operation of same, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 16 August 2017
Resolution: witnessed proper operation
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 15 August 2017
Resolved
Repair and demonstrate proper operation of fire damper for engine enclosure, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 16 August 2017
Resolution: witnessed proper operation.