Inspection history · 16
9 June 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8155739
27 May 2025
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8144603
28 October 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8025962
10 July 2024
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7955128
12 October 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7806466
8 July 2022
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7503618
22 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7435875
13 September 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7311276
21 July 2020
Internal Structural Exam · Deficiency Check · COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7011935
9 September 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6805508
14 August 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6783268
10 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6532479
20 August 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6518380
20 September 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6254829
19 September 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6000710
17 August 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5974621
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 May 2025
Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR Part 80, whichever comes sooner. The vessel's ERPIB battery was expired.
Vessel's route is restricted to 1000 feet offshore until this deficiency is rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: Battery replaced, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel master lacked training in his responsibilities as Vessel Security Officer.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: Training conducted, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 May 2025
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Fire suppression system panel on the bridge was not securely mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: Gauge mounted, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 May 2025
Resolved
All electrical equipment and circuits must be clearly marked and identified. Fire suppression system panel on the bridge did not have labeled batteries. Additionally, on the bridge breaker panel, breaker #1 was not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 28 May 2025
Resolution: Labels added.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. On the bridge breaker panel, breaker #32 was missing with no blank installed. On the bridge DC panel, bus breaker #4 was missing with no blank installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 28 May 2025
Resolution: Blanks installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 May 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests: For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by NFPA 10...with the frequency specified by NFPA 10. Fire extinguisher monthly inspections are not being logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: logs updated, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 May 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date...Coast Guard Light List. Vessel did not have Coast Guard Light List publication.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: Publications updated, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Donning instructions for both child and adult life jackets were not posted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: Placards posted, All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 May 2025
Resolved
The position of the rudder, if power-operated, must be shown at the principal steering station. Rudder angle indicators on the bridge were out of sync.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 2 July 2025
Resolution: All sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 May 2025
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device...A self-propelled vessel that is certificated to carry more than 150 passengers. Vessel does not have a Class A AIS device.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 18 September 2025
Resolution: AIS ordered, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 October 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection and testing of smoke and fire detecting systems
Fire detection panel shall be in proper working order
46 CFR 115.810(a)(7) 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2024
Resolution: Technician replaced diode and system operated properly. Service report provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 September 2021
Resolved
water intrusion from penetrations for the chairs on the upper deck coming into the overhang over the bathroom. Find leak and fix and seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 4 November 2021
Resolution: water intrusion from upper deck into the bathroom overhang was found and sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2021
Resolved
replace 06 lifejackets identified.
Action required: 10 - Deficiency Rectified
Resolved 13 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 August 2020
Resolved
the number and identification of lifesaving equipment stored inside a container must be clearly marked on each container. label each storage location of lifejackets with number of lifejackets.
46 CFR 122.604
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2020
Resolved 16 September 2020
Resolution: Life jacket stowage was marked temporarily while waiting for placards to be delivered.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 August 2020
Resolved
pre-engineered systems must automatically shut down all engines that draw intake air from the protected space. pre-engineered system in STBD engine compt did not shut down generator in the space.
46 CFR 188.420
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2020
Resolved 16 September 2020
Resolution: Technician located a disconnected signal wire in the pilot house. Tested SAT.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 25 August 2020
Resolved
each rudder angle indicator must be actuated by movement of the rudder. STBD rudder angle indicator was not fuctioning.
46 CFR 113.40-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2020
Resolved 7 October 2020
Resolution: Sending unit was replaced, test SAT.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 August 2020
Resolved
emergency instructions must be posted at the operating station.
46 CFR 122.510
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2020
Resolved 16 September 2020
Resolution: Emergency instructions were posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 July 2020
Resolved
03110 - A hatch cover must have securing devices; and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Both Port and Stbd fuel tank space hatch cover retention cables need to be reattached.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Cables were reattached to the hatch covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2020
Resolved
13199 - Hose end fittings must comply with SAE J1475.
Stbd Steering hose fitting wasted and needs replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Hydraulic steering hose was renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 July 2020
Resolved
03110 - Hatch must be watertight.
Port and Stbd FWD hatch gaskets need to be adhered to hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Hatch gaskets were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2020
Resolved
13101 - Electrical equipment and installation must be suitable for the roll, pitch, and vibration of the vessel underway.
Port engine transmission control panel needs to be mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Control enclosure was properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 July 2020
Resolved
09219 - Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration.
Replace stbd engine room generator fuel hose and check valve located in bilge.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Fuel lines were satisfactorily mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 July 2020
Resolved
13102 - Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] salt water cooling flange/pipe before valve is leaking.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Pipe flange and associated piping was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2020
Resolved
11118 - Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
Condemned 33 lifejackets that were deteriorated and ripped.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: All condemned life jackets were removed and replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2020
Resolved
11118 - Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
Stbd side lifering needs replaced.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2020
Resolved 25 August 2020
Resolution: Starboard life buoy was replaced.
Fire Fighting › Fire Pumps › Pressure
Issued 20 September 2017
Resolved
46 CFR 118.300 - Fire pump not providing adequate pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Resolution: Fire pump produced adequate pressure.
Engineering › Fuel Oil Service System › Valve
Issued 20 September 2017
Resolved
46 CFR 119.455 - Port fuel shutoff vlave inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Resolution: Port fuel shutoff vlave now operable.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 September 2017
Resolved
46 CFR 122.520 - Unable to demonstrate drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Resolution: Vessel crew demonstrated MOB and fire drills satisfactorily.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 September 2017
Resolved
46 CFR 127.410 - Repair broken Stbd window in pilot house.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 12 October 2017
Resolution: Vessel crew repaired broken Stbd window in pilot house.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 September 2016
Resolved
Fixed gas extinguishing system engine shut off not working in port engine room. Prove proper operation and provide service report.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2016
Resolution: properly tested engine shutdowns for the fixed gas system.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 September 2016
Resolved
Conduct man overboard drill prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2016
Resolution: successfully conducted a man overboard drill.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 August 2016
Resolved
Replace port side strut cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 August 2016
Resolution: New Cutlass bearing installed.