Records from 2005 to 2024. Most recent: inspection, 13 July 2024.
Inspection history · 23
13 July 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7957341
6 March 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7140048
24 October 2016
NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6022407
25 May 2012
NPV Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4321404
9 January 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4208765
2 November 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3880944
17 August 2008
ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3300619
17 August 2008
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3302972
14 August 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3298423
13 June 2008
ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3234635
13 June 2008
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3238904
10 June 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3232839
10 June 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3232848
7 March 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3155003
5 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2859636
2 January 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2848980
29 September 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2789707
22 September 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2779307
19 September 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2779189
16 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2393302
15 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2399065
14 June 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2390632
11 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2387284
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 March 2021
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. When completing deck walk, PSC examiners observed a 1" hole in the auxilary line feeding of the fire main after testing.
74 SOLAS (14 cons.) Ch. II-2/Reg.14.2.1.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2021
Resolved 12 March 2021
Resolution: Clear to satisfaction of class and Coast Guard
Construction/Loadline › Markings › Load Line Mark
Issued 9 January 2012
Resolved
The deck line shall be painted in white or yellow on a dark back ground or in black on a light background. The deck line is permanently marked on the side of the ship but was not painted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 January 2012
Resolved 9 January 2012
Resolution: Vessel painted deckline in the presence of the USCG. Def was corrected on the spot.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 9 January 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 11 January 2012
Resolution: Vessel master e-mailed a copy of the chief eng. temp flag state endorsement. Vessel was allowed to leave port of Mobile.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 7 March 2008
Resolved
Self closing fire door in main stairway does not shut properly. This creates a breach in the fire boundary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2008
Resolution: Self closing door shuts properly after adjustment. Resolved during inspection.
Lifesaving › Launching Appliances › Release Mechanism
Issued 7 March 2008
Resolved
Hydrostatic release for life and rescue boat on port and starboard side are expired. This creates a potential hazard for the crew. Rectify to the satisfaction of Class [17a].
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 March 2008
Resolution: Received Class report, stating, "Three (3) new Hydrostatic Release aUnits for Life Raft located on Boat Deck and Forward Upper Deck were replaced with old oned. Manufactured by HAMMEAR. Expired Date: March 2010."
Lifesaving › Lifebuoys › Quantity
Issued 7 March 2008
Resolved
Missing two (02) life buoys that went overboard while underway. This creates a potential hazard for the crew. Rectify to the satisfaction of Class (17a).
Action required: 705 - Other - as specified
Resolved 9 March 2008
Resolution: Received Class report, stating, " Two (2) new life buoys were installed on both side of upper decl. Manufactured by DATREX INC. KINDER, U.S.A."
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 27 February 2008
Resolved
Missing current (2008) tide tables and tidal current tables. This creates a navigational hazard. Rectify to satisfaction of Class (17a).
Action required: 705 - Other - as specified
Resolved 9 March 2008
Resolution: Received Class report, stating, "The following documents were provided on board the ship. Pacific Coast Current Table 2008, West Coast Tide Tables 2008, DMA Pub.111 List of Lights. West Coast of North and South America, BA Tide Table NP80 2007/08."
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 January 2007
Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation Act of 2004. In accordance with COMDT G-PCV-1, Vessel Response Plan Program NTVRP Verification Guidance e-mail dated 02 January 2007.
Action required: 705 - Other - as specified
Resolved 7 March 2008
Resolution: USCG APPROVED NON-TANK VESSEL RESPONSE PLAN WAS VISUALLY VERIFYED TO BE ON BOARD