Records from 1994 to 2021. Most recent: inspection, 12 July 2021.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 36
12 July 2021
Initial Certification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7253267
15 October 2015
MARPOL · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5743541
5 June 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5145066
1 June 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5143139
23 January 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5060567
18 July 2012
Industry Initiated Exam · MARPOL · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4397179
22 September 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3602955
30 October 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3354126
30 October 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3354148
30 October 2008
Uninspected Other
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3361630
3 November 2007
Deficiency Check · Uninspected Other
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3092734
24 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2940054
26 October 2006
MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2808738
29 August 2006
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2770606
29 January 2006
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2580761
19 January 2006
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2569259
15 January 2006
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2568625
11 January 2006
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2565221
5 August 2005
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2452145
8 July 2005
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2419427
29 January 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1996921
22 January 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2245882
9 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982996
1 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1975477
27 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1973322
2 April 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1767401
9 August 2002
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1660352
26 October 2001
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 674943
14 July 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522460
14 July 2001
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522466
17 August 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 211862
26 March 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 71130
10 February 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 135240
19 February 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756881
18 February 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 196223
23 September 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 186096
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for the safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port/Starboard shaft seal leak was excessive to the point of major concern. Def was spot corrected by port engineer who tightened packing glads.
46CFR143.205
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
Resolution: Def was spot corrected by port engineer who tightened packing glads. Leak was reduced to a few drips per minute.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2021
Resolved
Port engine bilge discharge pump piping had leak. Piping and tanks must be made of metal and maintained in a leak free condition.
46CFR143.270
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 11 August 2021
Resolution: Company rep submitted objective evidence and letter from TPO clearing def.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 July 2021
Resolved
Flamable storage locker was not secured to the vessel so that it does not move. If a dedicated storage cabinet is provided it most be secured to the vessel so that it does not move.
46CFR142.225
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 23 July 2021
Resolution: Rep submitted objective evidence clearing def.
Fire Fighting › Fire Pumps › Pressure
Issued 30 October 2008
Resolved
Noted considerable lack of water pressure generated by vsl fire pump.
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: Vessel had sufficient fire hose PSI.
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 October 2008
Resolved
Noted that vsl had niether a magnetic compass or a swing meter.
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: Vessel had magnetic compass onboard.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 October 2008
Resolved
Noted vsl name not stenciled/not readable on throwable life rings/ring buoys.
Due 30 November 2008
Resolved 18 July 2012
Resolution: Vessel had USCG approved lifering onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 30 October 2008
Resolved
Noted many portable fire extinguishers strewn randomly about the vsl. Vsl to provide mounting brackets or safe storage location.
Due 30 November 2008
Resolved 18 July 2012
Resolution: All protable extingiushers were in marine type brackets.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 3 November 2007
Resolved
Port side detector was not operable and starboard side detector face plate was missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 November 2007
Resolution: Vessel faxed over technician report stating satisfactory operation of both heat detectors.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 November 2007
Resolved
Machinery guard on port generator is broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2007
Resolved 5 November 2007
Resolution: Vessel faxed over Technician report stating the guard was replaced with satisfactory results.
Navigation › Piloting/Steering
Issued 29 January 2004
Resolved
Coast Guard Light list out of date. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 18 May 2004
Documentation › Certificates/Documents
Issued 29 January 2004
Resolved
Certificate of Documentation is valid, however, the COD was not on the vessel. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Due 27 February 2007
Resolved 18 May 2004
Documentation › Logs/Records
Issued 29 January 2004
Resolved
No vessel log or receipts for disposal of plastics and other garbage. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 27 February 2004
Resolved 18 May 2004
Accommodation/Occupational Safety › Potable Water System
Issued 29 January 2004
Resolved
No bug screens on potable water vents.
Due 27 February 2004
Resolved 18 May 2004
Documentation › Markings/Placards
Issued 29 January 2004
Resolved
No prohibited discharge placards. LEGACY COMPONENT DESC: Garbage Placard
Due 27 February 2004
Resolved 18 May 2004
Documentation › Markings/Placards
Issued 29 January 2004
Resolved
No oil discharge placards. LEGACY COMPONENT DESC: Oil Discharge Placard
Due 27 February 2004
Resolved 18 May 2004
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 29 January 2004
Resolved
No Employee Assistance Program educational/hotline info is posted.
Due 31 August 2004
Resolved 31 August 2004
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 29 January 2004
Resolved
No company chemical testing program and policy aboard.
Due 27 February 2004
Resolved 31 August 2004
Operations/Management › Mandatory Ship Reporting Systems
Issued 29 January 2004
Resolved
No log for deck equipment inspections. No vessel log with required tests and inspections. LEGACY COMPONENT DESC: Entry Report
Due 27 February 2004
Resolved 18 May 2004
Lifesaving › Work Vest
Issued 29 January 2004
Resolved
Work vests in poor condition and no retroreflective material.
Due 27 February 2004
Resolved 18 May 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 January 2004
Resolved
PFDs in state rooms inaccessible.
Due 27 February 2004
Resolved 29 January 2004
Resolution: Corrected on spot.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 29 January 2004
Resolved
No oil transfer procedures or piping diagrams.
Due 27 February 2004
Resolved 31 August 2004
Fire Fighting › Miscellaneous Items
Issued 29 January 2004
Resolved
Equipment stored on fire extinguishers in engine rooms.
Due 27 February 2004
Resolved 18 May 2004
Electrical › Lighting (service)
Issued 29 January 2004
Resolved
No guards on engine room lights.
Due 27 February 2004
Resolved 18 May 2004
Navigation › Collision/Grounding Avoidance
Issued 29 January 2004
Resolved
Searchlight bulb out. Bulb on order. LEGACY COMPONENT DESC: Searchlight
Due 18 May 2004
Resolved 29 January 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 29 January 2004
Resolved
No flame screens on fuel vent pipes. LEGACY COMPONENT DESC: Vent Pipe
Due 27 February 2004
Resolved 18 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 29 January 2004
Resolved
Smoke alarms do not work.
Due 18 May 2004
Resolved 29 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 29 January 2004
Resolved
No notice of noise hazards posted in engine room.
Due 27 February 2004
Resolved 18 May 2004
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 29 January 2004
Resolved
Water in port side fuel fill station on stern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 31 August 2004
Deck/Cargo › Towing › Towline
Issued 29 January 2004
Resolved
Starboard "push cable" unserviceable. Appeared to have been flattened.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 31 August 2004