Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)25.7 ft × 17.4 ft × 5.3 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSMIOTH CONSTRUCTION CO · STEVENSON, WA, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 June 2025 · expires 30 June 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton 12 - Simplified, Net Ton 33 - Dead Weight, Ton 22 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 December 2022Resolved
You must have a fire detection system installed on your vessel to detect engine room fires. Any owner of a vessel whose construction was contracted for before January 18, 2000, may use an existing engine room monitoring system (with fire detection capability) instead of a fire detection system, if the monitoring system is operable and complies with this section. No fire detection system installed onboard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 3 February 2023
Resolution: Visual inspection and documentation provided by owner sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2022Resolved
You must carry on your towing vessel both-the minimum number of hand portable fire extinguishers required by subpart 25.30 of this part; and: An approved 160-B or 100 lb CO2 extinguisher, regardless of rating, to protect the engine room; or a fixed fire extinguishing system installed to protect the engine room of the vessel. No currently serviced semi portable or fixed extinguishing system were onboard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 11 January 2023
Resolution: Verified proper semi portable onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2022Resolved
All motorboats must carry at least the minimum number of portable fire extinguishers set forth in table 25.30-20(a)(1): One 5-B portable extinguisher. Vessel did not have currently serviced 5-B portable extinguisher onboard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 12 January 2023
Resolution: Verified 5-B onboard.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 December 2022Resolved
To stop the flow fuel in the event of a break in the fuel line, you must have a positive, remote fuel-shut-off valve fitted on any fuel line that supplies fuel directly to an engine or generator. It must be operable from a safe place outside the space where the valve is installed. Each remote valve control should be marked in clearly legible letters 1 inch high, indicating the purpose of the valve and the way to operate it. Fuel shut off within void does not have remote valve.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 12 January 2023
Resolution: Verified fuel shutoff onboard.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 December 2022Resolved
You must ensure that your vessel is fitted with a general alarm that: has a contact maker at the operating station that can notify persons on board in the event of an emergency. Is capable of notifying persons in any accommodation, work space, and the engine room. Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: Attention General Alarm – When Alarm Sounds or Flashes Go to Your Station. No general alarm installed onboard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 11 January 2023
Resolution: Verified installation and operation of general alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2022Resolved
The official number of the vessel, preceded by the abbreviation “NO.” must be marked in block type Arabic numerals not less than 3 inches in height on some clearly visible interior structural part of the hull. Official number not marked in accordance with the requirements.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 11 January 2023
Resolution: Verified official number marking in engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2022Resolved
For vessels having a square bow, the name of the vessel must be marked on some clearly visible exterior part of the bow in a manner to avoid obliteration. The name and hailing port must be marked on some clearly visible exterior part of the stern.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 11 January 2023
Resolution: Verified name and hailing port marked on vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 December 2022Resolved
The master or person in charge of a vessel must ensure that each crewmember participates in drills and receives instruction at least once each month. You must ensure that all crewmembers are familiar with their fire fighting duties. No record of training or drills were available.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 December 2022
Resolved 3 February 2023
Resolution: Owner provided training & drill logs.
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 December 2022
Resolution: Owner removed portion of the vessel to less than 26 ft and is not required to comply with Subchapter M.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018Resolved
MMSI: Vsl is broadcasting invalid MMSI, CLSN: Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 December 2022
Resolution: Verified proper MMSI number.