MAURY USCG vessel records Sign in
← All vessels

EIDE TRANSPORTER

EIDE TRANSPORTER is a 1988 freight ship. The Coast Guard has recorded 9 inspections since 2005, most recently in October 2016, along with 13 deficiencies and 1 operational control.

Records from 2005 to 2016. Most recent: operational control imposed, 8 October 2016.

Built
1988
Last inspected
8 October 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8030130 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
760126
Flag
BAHAMAS, THE
—
Maury page id
psix-760126

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2005–2016)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19579 - Convention (Subpart B), Gross Ton
5873 - Convention (Subpart B), Net Ton
11306 - Dead Weight, Metric Ton
19585 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

8 October 2016 Deficiency Check · COE-Dockside · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6018759
27 May 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5882831
30 May 2014 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4874602
20 May 2014 ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4858629
12 June 2012 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4341796
1 June 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4330864
11 April 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2905817
27 June 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2404564
21 June 2005 PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2397678

Deficiency record · 13

Documentation › Logs/Records › Oil Record Book
Issued 27 May 2016 Resolved
1710-ORB-The ORB shall be in teh form specified in MAPROL I/App. III and completed on each occasion, when any of the following ops takes place: collection/disposal of oil. During review of the ORB, PSCO noted inconsistencies regarding the weekly retention sounds of tanks listed in 3.1 of the ship's IOPP Form A between 29Nov15-5May16 & 18Sep15-31Oct15. Also, 8+ cubes of ol was unaccounted for. 16b
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 12 October 2016
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 May 2016 Resolved
9900-Other-No person may use equip. for transfer ops. unless the vessel operator conducts annual, biennial, or mid-period inspection tests to ensure that the equipment will not burst, bulge, leak, or abnormally distort under static liquid pressure at least 1.5 times the maximum allowable working pressure. The crew was unable to provide hydro. test records for tests conducted since 2013. 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 June 2016
Resolved 12 October 2016
Resolution: Reviewed maintenance logs and records.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 12 June 2012 Resolved
Vessel's steering gear does not operate properly, the rudder angle on the rudder stock does not match the rudder angle indicator on the bridge. At an order rudder angle of 30 degrees on the bridge the rudder stock shows 35 degrees.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 April 2013
Resolution: PSCE Verified rectification while conducting steering gear test.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 6 June 2012 Resolved
1499 - OTHER (PROP. & AUX. MACHINERY) - Vessels steering gear does not operate properly. The rudder angle on the rudder stock does not match the rudder angle indicator on the bridge at an ordered rudder angle of 30deg. on the bridge the rudder stock shows 37 deg. 74SOLAS CH II-I REG29 STEERING GEAR
Due 12 June 2012
Resolved 12 June 2012
Resolution: Report received from Class to satisfactory temporary repairs.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 June 2012 Resolved
1420 - CLEANLINESS OF THE ENGINE ROOM - Vessels main engine room has numerous oil leaks using buckets to catch the oil. Vessel must make repairs to the equipment with in 30 days to the satisfaction of the classification society. 74SOLAS CH-I REG 11 MAINTENANCE OF CONDITIONS AFTER SERVEY
Condition: Improper/Lack of Maintenance
Due 6 July 2012
Resolved 12 June 2012
Resolution: Received Class report to satisfactory repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2012 Resolved
0950 - ELECTRIC EQUIPMENT IN GENERAL - Multiple electrical hazards exist in main engine room and pump room. Vessel to make repairs prior to departure to the satisfaction of the classification society. 74 SOLAS CH.II-I REG 27 PRECAUTIONS AGAINST SHOCK, FIRE AND OTHER HAZARDS OF ELECTRICAL ORIGIN.
Due 12 June 2012
Resolved 12 June 2012
Resolution: Received Class report to satisfactory repairs.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 June 2012 Resolved
1420 - CLEANLINESS OF ENGINE ROOM - Oily rags through out the engine room. 74SOLAS CH-II REG 11 MAINTENANCE OF CONDITIONS AFTER SERVEY.
Due 6 July 2012
Resolved 12 June 2012
Resolution: Received Class report to satisfactory repairs.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 June 2012 Resolved
1420 - CLEANLINESS OF THE ENGINE ROOM - Oil soaked lagging throughout the main engine room.74SOLAS CH-I REG11 MAINTENANCE OF CONDITIONS AFTER SERVEY
Condition: Improper/Lack of Maintenance
Due 6 July 2012
Resolved 12 June 2012
Resolution: Received Class report to satisfactory repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2005 Resolved
installed flood lights in engine room aft are missing glass covers and/or metal guards, globe lights are missing guards.
Action required: 705 - Other - as specified
Due 29 July 2005
Resolved 10 April 2007
Resolution: guards had been intalled
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 June 2005 Resolved
repair damaged handrails port side at main deck level.
Action required: 705 - Other - as specified
Due 29 July 2005
Resolved 10 April 2007
Resolution: handrails had been replaced/repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 June 2005 Resolved
shaft coupling for ballast pumps in forward engine room are missing coupling guard.
Action required: 705 - Other - as specified
Due 29 July 2005
Resolved 10 April 2007
Resolution: coupling guard in place on ballast pumps
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 21 June 2005 Resolved
sewage tank blower motor was found inoperative.
Action required: 705 - Other - as specified
Due 29 July 2005
Resolved 10 April 2007
Construction/Loadline › Markings › Load Line Mark
Issued 21 June 2005 Resolved
load line marks are not visible, paint in contrasting color.
Action required: 705 - Other - as specified
Due 29 July 2005
Resolved 10 April 2007
Resolution: all marks were painted in contrasting color

Ownership record