Records from 2005 to 2016. Most recent: inspection, 13 December 2016.
Inspection history · 13
13 December 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6056863
12 December 2016
In-Service Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6056192
9 December 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6055600
12 April 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5852186
25 October 2010
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3878847
31 July 2008
Annual Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3278356
9 June 2008
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3231675
3 July 2007
Deficiency Check · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2977768
19 April 2007
Hull Examination · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2911147
23 January 2006
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2571790
17 September 2005
Damage Survey · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2496132
14 September 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2498576
12 July 2005
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2423260
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 December 2016
No resolution recorded
Vessel caught fire will driving with passengers on MacArthur Causeway. Passenger area and engine compartment destroyed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017 — due date passed with no resolution recorded
Fire Fighting › Fire Bucket › Lanyard
Issued 31 July 2008
Resolved
Provide lanyard for third fire bucket.
Due 31 August 2008
Resolved 16 January 2013
Resolution: New fire buckets provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 July 2008
Resolved
Repair all identified dead end wires.
Due 31 August 2008
Resolved 16 January 2013
Resolution: Conducted ISE 26NOV2012 and identified wire issues and corrected.
Communications › Alarms/Indicators › Fire Alarm
Issued 31 July 2008
Resolved
Prove proper operation of audible & visual alarms for fixed fire fighting shut down system.
Due 31 August 2008
Resolved 16 January 2013
Resolution: Fixed fire extinguishing system for the machinery space tested. Witnessed audible/visual alarm and shutdown and restart of blower fans and diesel engine.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 July 2008
Resolved
Adjust & lubricate emergency fuel oil shut off valve.
Due 31 August 2008
Resolved 26 November 2012
Resolution: Tested sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 31 July 2008
Resolved
Remove all water & oil from bilge.
Due 31 August 2008
Resolved 26 November 2012
Resolution: Bilges cleaned.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 31 July 2008
Resolved
Remount fire extinguisher in stern.
Due 31 August 2008
Resolved 16 January 2013
Resolution: Extinguisher mounted.
Construction/Loadline › Hull › Keel
Issued 31 July 2008
Resolved
Submit repair proposal for relaminating bow.
Due 31 August 2008
Resolved 26 November 2012
Resolution: Discussed repair and examined repair to headlight housing.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 31 July 2008
Resolved
Fix insulation around jet pump drive shaft.
Due 31 August 2008
Resolved 16 January 2013
Resolution: Insulation repaired.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210
Due 5 July 2008
Resolved 25 August 2008
Resolution: Company has signed up with a consortium. Both the company and consortium receive pre-employment results.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Company did not have records of pre-employment as required by 46 CFR 40.25
Due 5 July 2008
Resolved 7 December 2012
Resolution: Closed activity; vessel out of service in D11 since 24 Apr 09.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 5 July 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium is currently using a computer based selection program for the company''s random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Statistically based method not currently being used to determine when random testing takes place as required by 46 CFR 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium is currently using a computer based selection program for the company''s random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230
Due 5 July 2008
Resolved 25 August 2008
Resolution: Company and consortium drafted a list of all safety-sensative personnel to be tested.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: EAP policy posted on all vessels.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Employer does not have a Substance Abuse Professional (SAP) name and contact information as required by 49 CFR 40.287.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium provided 2 hours worth of EAP training to company''s supervisors.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Supervisors had not received 1 hr. of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: EAP hotline phone number posted with EAP policy on all vessels.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
MIS form not submitted by March 15 as required by 46 CFR 16.500
Due 5 July 2008
Resolved 3 July 2008
Stability › Unintentional Flooding › General
Issued 3 July 2007
Resolved
Prove proper operation of second bilge high level alarm in way of one aft of engine.
Action required: 705 - Other - as specified
Due 14 July 2007
Resolved 12 July 2007
Documentation › Logs/Records › Logbook (official)
Issued 3 July 2007
Resolved
Provide vessel specific daily safety checks list as discussed.
Due 14 July 2007
Resolved 12 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 July 2007
Resolved
Properly stow 5th child size PFD.
Action required: 705 - Other - as specified
Due 14 July 2007
Resolved 12 July 2007
Operations/Management › Drills/Instruction › Safety Orientation
Issued 3 July 2007
Resolved
Provide and demonstrate training program in place with any new operator and deckhand.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 11 October 2007
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 3 July 2007
Resolved
Properly install hull markings IAW 46CFR 67.123.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 11 October 2007
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 19 April 2007
Resolved
Manufacturer of Trolleyboats to provide an Operations Manual for review and approval to Sector Jacksonville OCMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2007
Resolution: Received manual. Manual meets basic requirements. Sector Jacksonville will work with Trolleyboats, LLC to improve manual and gather any input from Sector San Fransisco.
Construction/Loadline › Hull › Hull Plating
Issued 10 January 2006
Resolved
Submit plans approved by MSC as well as a repair proposal to this office prior to commencing repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2006
Resolved 24 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 10 January 2006
Resolved
Make repairs IAW drawings & calculations approved by MSC. Repair proposal to be submitted for approval prior to beginning repairs all to the satisfaction of the attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 17 September 2005
Resolved
Owners rep reported a hull breach caused by the port side of the rear axle separating from the hull. Also verify satisfactory installation of front axle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007