GENER8 DEFIANCE is a 2002 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in January 2017, along with 1 deficiency and 2 operational controls.
Records from 2016 to 2017. Most recent: inspection, 2 January 2017.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it56225 - Convention (Subpart B), Gross Ton 32059 - Convention (Subpart B), Net Ton 105538 - Dead Weight, Metric Ton 121481 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
2 January 2017COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6063432
16 November 2016Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6042234
16 August 2016COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5967178
11 June 2016Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5904119
Electrical › Electrical Distribution System (service) › Cable
Issued 10 April 2016Resolved
Exposed wiring outside of the explosion proof box of thermal couple on Cargo Pump #1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 25 April 2016
Resolution: Received proper documentation from DNV-GL attesting to the repairs to the #1 COP thermal couple wiring fittings for the hazardous area.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.