Records from 2005 to 2024. Most recent: inspection, 24 July 2024.
Inspection history · 16
24 July 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7965272
20 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7692706
14 June 2022
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7471688
4 October 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6828351
3 October 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6827960
11 May 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6138686
28 April 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5859299
23 August 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3306356
16 April 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2908858
20 February 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2874461
25 August 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2759398
23 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2757774
23 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2813125
25 July 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2716909
14 February 2006
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2584840
29 June 2005
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2407888
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 July 2024
No resolution recorded
The arrangements shall ensure that the tightness can be maintained in any sea conditions and for this purpose tests for tightness shall be required at the initials urvey, and may be required at periodical surveys and at annual inspections or at more frequent intervals. PSCO detected air was leaking through hospital space weathertight door leading to exterior weather deck. PSCO conducted chalk test on the weathertight door, which failed, idicating a 10-12 inch gap. ICLL 66/88 ANNEX I/ REG 16.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 June 2022
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met. Means shall be provided to control the leaks of flammable liquids.
PSCO observed fuel leaks on both the number one and number two auxiliary diesel generators. High pressure fuel pumps number one and four on the number two auxiliary diesel generator found leaking. High pressure fuel pump number six on the number one auxiliary diesel generator found leaking.
74SOLAS (04) II-2/4.1.1
60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 14 June 2022
Resolved 15 June 2022
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. O-rings and gaskets on affected High Pressure Fuel Pumps were replaced and both Aux Engines were tested satisfactorily.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 20 February 2007
Resolved
Ballast water handling log and sediment records are not being used in accordance with company approved ballast water management plan. 33CFR151.2035
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2007
Resolution: Received satisfactory ballast water logs and records.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 20 February 2007
Resolved
SOLAS training manual has not been provided in the officer's mess room. SOLAS 74 (2006) II-2/ 15.2.3, III/ 35
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2007
Resolution: Received satisfactory class report.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 February 2007
Resolved
Fire doors in accommodation spaces required to be self closing on fire control plan are fitted with manual hold back hooks. SOLAS 74, (2004 con.) II-2/ 9.4.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2007
Resolution: Received satisfactory class report.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 February 2007
Resolved
Smoke detectors are being tested with cigarettes or by burning mosquito coils, instead of test gas. This creates a fire ignition hazard, especially in the engine room. Provide suitable testing procedures and equipment to the satisfaction of class society. FSS Code 9.2.5.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2007
Resolution: Received satisfactory class report.