Records from 2017 to 2019. Most recent: inspection, 29 January 2019.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2019
No resolution recorded
17AC-Deficiency shall be rectified to satisfaction of class and USCG
The condition of the ship and its equpment shall be maintained to ensure the ship will remain fit to proceed to sea. The No. 4 and No. 6 Cylinder on main engine is leaking jacket water. Chief Engineer claims crew does not have time to repair.
-SOLAS 14 Cons. I/II
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2019 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 January 2019
Resolved
17AC-Deficiency shall be rectified to satisfaction of class and USCG
Internal combustion engines of 2500 KW and above shall be provided with crankcase oil mist detectors. The oil mist detector for main engine, No. 1 and No. 2 Aux engines shows fault and is isolated. Repair prior to operating unattended machinery space.
-SOLAS 14 Cons. II/1/47.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2019
Resolved 28 January 2019
Resolution: Issue was repaired and corrected to satisfaction of DNV-GL
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 January 2019
Resolved
17AC-Deficiency shall be rectified to satisfaction of class and USCG
Fire extinguishing appliances shall be readily available. The crew could not demonstrate water delivery on deck from main fire pump for 90 minutes. Engineers trouble shot and corrected. Provide corrective action plan.
-Solas 14 Cons. II-2/10.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2019
Resolved 28 January 2019
Resolution: Issue was corrected to satisfaction of DNV-GL.
Construction/Loadline › Hull › Bottom Plating
Issued 16 February 2018
Resolved
The company should establish procedures, plans and instructions, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The vessel's current procedure for anti-fouling do not adequately address preventing excessive marine growth on the vessel's hull. 74 SOLAS (14) IX/3.1 ISM Code 7
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 16 February 2018
Resolution: Cleared by class
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 February 2018
Resolved
1730 - Oil filtering equipment shall be designed to ensure that any oily mixture discharged into the sea after passing through the system does not exceed 15ppm. When the crew ran clean water through the OWS, the system did not produce an effluent below 15ppm. When the crew opened the tri-gate valve, there was oily residue in the overboard discharge piping. MARPOL Annex I/14.6 30 a c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2018
Resolved 16 February 2018
Resolution: Cleared to the satisfaction of Class and the Coast Guard
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 15 February 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the persons on board. A steam pip leak was discovered on the number 1 cylinder. Site 74 Solas (14)11a.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2018
Resolution: Cleared by class
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 15 February 2018
Resolved
The machinery and associated piping shall be constructed adequate for the service for which they are intended. The vessel's crew installed unapproved piping on the seachest to act as a drainage line, which is not in accordance with the intended design. 74SOLAS (04) Ch. II-2 Reg. 26.1 40 a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2018
Resolution: Cleared by class
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 February 2018
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. 03 galley fire doors were found held open using hold back hooks. Upon discovery, crew removed all hold-back hooks. 74SOLAS(04)Ch. II-2 Reg. 9.4.2.2 10 c
Due 15 February 2018
Resolved 15 February 2018
Fire Fighting › Structural - B Class Divisions › Doors
Issued 15 February 2018
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted. PSCO discovered a class "C" door installed in the galley, where a class "B" boundary is clearly indicated on the fire control plan. 74SOLAS(04) Ch. II-@ Reg. 9.4.2.1 17a
Action required: 60 - Rectify deficiencies prior to movement
Due 15 February 2018
Resolved 16 February 2018
Resolution: Cleared by class
Engineering › Fuel Oil Service System › Filter
Issued 15 February 2018
Resolved
All pressure vessels and piping systems shall be of design and construction adequate for the service of which they are intended. There is an alternate, unapproved venting arrangement, supplying cooling air to the fuel oil discharge filter. 74SOLAS(04) Ch. II-! Reg. 26.1 17a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 February 2018
Resolution: Cleared by class
Construction/Loadline › Markings › Load Line Mark
Issued 15 February 2018
Resolved
Loadline - The rings, lines, and letter shall be painted in a white or yellow on a dark ground or in a black on a light ground. The loadline on the port side was not painted and excessively rusted. Vessle's crew painted the loadline prior to PSCOs departing. ICLL (88) Reg. 8 10c
Due 15 February 2018
Resolved 15 February 2018
Construction/Loadline › Hull › Hull Plating
Issued 15 February 2018
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements covered by the survey, without the sanction of the administration. Excessive rust and pitting was discovered on the vessels hull. Additional buckling on the vessel's hull was discovered between the midship and port bow. Additionally, the vessel is not scheduled for dry-dock for two years. There is no mention of the buckling on the most recent hull survey. 74SOLAS(14) Ch.1 Reg. 11(B) 17a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 February 2018
Resolution: Cleared by class. Class imposed a condition on it, to be monitored
Engineering › Lubricating Oil Service System › Piping
Issued 15 February 2018
Resolved
The machinery and associated piping shall be constructed adequate for the service which they are intended. The vessel's crew installed unapproved piping on the main engine to act as drip catches, which is not in accordance with the intended design. 74SOLAS(04) Ch. II-I Reg. 26.1 40a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 February 2018
Resolution: Cleared by class
Construction/Loadline › Hull › Hull Plating
Issued 15 February 2018
Resolved
The person in charge of any vessel with ballast tanks that operates in the waters of the United Sates, must remove fouling organisms from the vessel's hull. The vessel was found to have excessive marine growth on the hull. Site: 33 CFR 151.2050 (f) 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2018
Resolution: Recieved class report.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 15 February 2018
Resolved
The safety management system should provide specific measures to promate the reliability of equipment and technical systmes. The company has not provided maintenance procedure for the oil content meter (OCM). The CE stated that they clean the OCM after being used, but neither the SMS nor technical manual instructs the crew to do so. PSCO recommends an audit from the certificate issuing authority. 74SOALS(14) IX/3.1 ISM Code 10.3 50ac
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 16 February 2018
Resolution: The company provided proper instruction. cleared by class.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 February 2018
Resolved
Main switchboards shall be arranged to give easy access as needed to equipment without danger to personnel. The main switchboard in the ECR was found to have a number of items stored behind it. Upon discovery, the CE removed all items. 78SOLAS(04) Ch. II-1 Reg. 45.2 10c
Due 15 February 2018
Resolved 15 February 2018
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 13 April 2017
Resolved
0750 - Fire Prevention - Oil fuel pipes, which, if damaged, would allow oil to escape from a storage or service tank having a capacity of 500+L situated above the dbl bottom, shall be fitted with a valve directly on the tank capable of being closed from a safe position outside the space. 03 quick closing valves were found blocked in the open position. SOLAS (14, Cons) II-2/4.2.2.3.4
Action required: 705 - Other - as specified
Resolved 13 April 2017
Resolution: Crewmembers removed holds from quick closing valves immediately. Tanks were not in service so deficiency was corrected on the spot.