MAURY USCG vessel records Sign in
← All vessels

BOX EMMA

BOX EMMA is a 2004 freight ship. The Coast Guard has recorded 20 inspections since 2005, most recently in July 2016, along with 5 deficiencies and 5 operational controls.

Records from 2005 to 2016. Most recent: inspection, 18 July 2016.

Built
2004
Last inspected
18 July 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9275646 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
764761
Flag
MARSHALL ISLANDS
—
Maury page id
psix-764761

Inspections, by type

…with no type recorded8
Years with a record 9 calendar years (2005–2016)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it54881 - Convention (Subpart B), Gross Ton
31783 - Convention (Subpart B), Net Ton
88301 - Displacement, Metric Ton
68121 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

18 July 2016 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5944668
8 July 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5933654
8 July 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5933984
6 July 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5931517
8 March 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4811944
4 June 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4334023
2 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4331617
24 May 2012 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4320495
5 August 2011 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4105749
18 December 2009 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3652545
28 February 2009 MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3425443
13 February 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3146885
22 May 2007 Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2937670
20 May 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2935132
22 February 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2875958
11 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2583505
9 February 2006 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2582199
19 November 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2537718
13 July 2005 ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2425286
2 July 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2411070

Deficiency record · 5

Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 July 2016 Resolved
1499-The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The steam heater for the fuel oil and M/E jacket freshwater cooler are both leaking water. 74 SOLAS (04 cons) II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2016
Resolution: Received class report stating all repairs have been made.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 6 July 2016 Resolved
0750-In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil. The lagging throughout the engine room, particularly on the main engine and in the purifier room was in disrepair, torn and oil soaked. 74 SOLAS (14) II-2/4.4.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2016
Resolution: Received class report stating all repairs have been made.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 12 July 2005 Resolved
Chief Mate was unable to provide proof of recurrent hazmat training . 49CFR 176.13 (40, C)
Action required: 705 - Other - as specified
Due 19 July 2005
Resolved 15 July 2005
Resolution: Received Master''s faxed attestation of [name withheld] hazmat refresher training.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 12 July 2005 Resolved
VESSEL unable to provide standard discharge connection. Marpol annex 1 reg 19, 73/78
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 29 July 2005
Resolution: Received faxed copy of class attestation to availability and location of standard discharge connection on board vessel.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 12 July 2005 Resolved
Vessel unable to provide static liquid test results for bunker line. 33 CFR 156 .170
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 15 July 2005
Resolution: Received Master''s faxed attestation of bunker line test.

Ownership record