MAURY USCG vessel records Sign in
← All vessels

CBR-764

CBR-764 is a 2005 freight barge. The Coast Guard has recorded 17 inspections since 2005, most recently in October 2025, along with 5 deficiencies.

Records from 2005 to 2025. Most recent: inspection, 31 October 2025.

Built
2005
Last inspected
31 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

765406
Flag
UNITED STATES
—
Maury page id
psix-765406

Inspections, by type

Years with a record 13 calendar years (2005–2025)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)134.4 ft × 40.0 ft × 9.0 ft
Registered tonnagegross 495 / net 148
ITC dimensions (L × B × D)134.4 ft × 40.0 ft × 9.0 ft
ITC tonnagegross 495 / net 148
BuilderSNEED SHIPBUILDING INC · CHANNELVIEW, TX, UNITED STATES · built 2005
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMILWAUKEE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 August 2026 · expires 30 September 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it495 - Convention (Subpart B), Gross Ton
148 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

31 October 2025 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 8261554
27 January 2020 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6897346
20 December 2018 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6600774
13 December 2017 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6323577
17 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6042874
8 January 2016 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5796659
5 November 2015 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5757794
27 March 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5091670
11 July 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4852441
2 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4857938
19 December 2013 Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4771549
17 August 2012 Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4412576
13 September 2010 Examination of Repairs · Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3851729
29 September 2008 Drydock Exam · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3334947
30 August 2007 Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3050167
17 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2857070
8 November 2005 Internal Structural Exam · Cargo Tank Internal · Hull Examination · Initial Certification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2530738

Deficiency record · 5

Construction/Loadline › Hull › Transverse Frame
Issued 5 November 2015 Resolved
6 Forward frames in the head log were bent and outter shell c/r along those frames.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 January 2016
Resolved 12 January 2016
Resolution: Cropped and renewed frames and a section of the head log.
Construction/Loadline › Hull › Side Shell
Issued 5 November 2015 Resolved
Port #3 AFT bulkhead/side shell folded. c/r location.
Condition: Damaged By Earlier Event
Due 9 January 2016
Resolved 12 January 2016
Resolution: Inserted a section of the stern box bulkhead. Conducted air test with satisfactory results.
Construction/Loadline › Hull › Weld
Issued 5 November 2015 Resolved
Cracked rub rail vertical along the aft end weld.
Condition: Damaged By Earlier Event
Due 9 January 2016
Resolved 12 January 2016
Resolution: Crack was repaired.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 2 May 2014 Resolved
Vessel has been limited to LBS. They are unable to put cargo tank covers on cargo tanks.
Action required: 705 - Other - as specified
Resolved 14 July 2014
Resolution: Reduce route to LBS and Limited Coastwise
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 5 September 2007 Resolved
Replace missing drain plugs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2007
Resolved 31 October 2008
Resolution: Drain plugs provided for scuppers to the Satisfaction of Attending MI

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.