Records from 2011 to 2026. Most recent: inspection, 5 August 2026.
Inspection history · 22
5 August 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8457420
7 October 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8248792
24 October 2024
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8020624
2 August 2024
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7975436
4 January 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7845077
7 November 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7838408
17 October 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7809950
8 November 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7598488
21 October 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7591329
11 August 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7530818
4 March 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7440152
20 October 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7336157
2 December 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7105020
20 October 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7081877
16 June 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6979860
12 February 2019
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6624527
16 October 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6561837
30 July 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6496252
31 October 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6298422
18 October 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6026580
6 July 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5932351
2 July 2016
Type not recorded
No type recorded · Station Annapolis · USCG East District (CGD-E) · Activity 5926960
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 October 2024
No resolution recorded
Each survival craft required on a vessel by this part must meet one of the following: For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. The life float must remain in good and serviceable condition. The life float connections to the netting have deteriorated rendering it unserviceable. Vessel is to replace life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 August 2024
Resolved
46 CFR 176.610(a)
During examination all accessable parts of the vessel's underwater body and all through hull fittings shall be made available for examination.
Vessel's raw water intake and wash down valves were non operational. Repair and replace to the satisfaction of the attending marine inspector prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 3 August 2024
Resolution: Thru hull valves were replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 August 2024
Resolved
46 CFR 176.600(c)(1)
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel is restricted from carrying passengers until credit dry dock is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2024
Resolution: Credit drydock was completed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 October 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel did not have a valid EPIRB registration onboard. Vessel is restricted to operation no more than 3nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2023
Resolved 7 November 2023
Resolution: Recieved EPIRB registration.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2022
Resolved
A power-driven vessel underway shall exhibit
a masthead light forward, Sidelights and a sternlight. Vessel Masthead light was inoperable and Anchor light had no protective cover. 33 CFR 83.23(a)
Action required: 705 - Other - as specified
Due 21 November 2022
Resolved 8 November 2022
Resolution: Received photgraphic evidence of replaced masthead and anchor light working as intended.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 October 2022
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. Vessels lifefloat was missing vessels name.
46 CFR 185.604(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 8 November 2022
Resolution: Vessel named added to lifefloat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 October 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicator for bilge pump in forward cabin was inop.
46CFR182.530(3)(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 1 November 2021
Resolution: Indicator was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2021
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Fuel filter for main engine was missing thermal shield.
46CFR182.455(b)(6)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 1 November 2021
Resolution: Flame shield was added to the fuel filters.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 October 2021
Resolved
Buoyant apparatus must not have any evident defects in workmanship. Life float had exterior damage that needed to be fixed.
46CFR160.010-4(I)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 8 November 2022
Resolution: Verified lifefloat repair as required.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 October 2020
Resolved
Life floats are to be arranged to float free and stowed with an approved weak link. The painter and weak link arrangement was not rigged in a manner that would allow the life float to float free.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 2 December 2020
Resolution: Owner re-rigged weak link correctly to allow life float to float free.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 October 2020
Resolved
The floating waterlight must be attached around the body of the life float by a 3/8 inch lanyard, resistant to deterioration from ultraviolet light, and at least 18 feet in length. The length of the floating waterlight line was less than 18 ft and not attached around the body of the life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 2 December 2020
Resolution: Owner provided photographic evidence of 18' line correctly attached to the waterlight and body of life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2020
Resolved
Each flare carried to meet this section must be stowed in one of the following: A portable watertight container marked as required by §185.614 of this chapter, carried at the operating station. Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 0.5 inches high: “DISTRESS SIGNALS”.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 2 December 2020
Resolution: Owner provided receipt and photo of new distress signal containiner with "FLARES" marking.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 October 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor light was not observable. Provide proof of operation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 2 December 2020
Resolution: Proof of anchor light operations provided by owner.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Severe chafing observed on port steering ram hydraulic hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 2 December 2020
Resolution: Owner provided photograph of new hydraulic hose installation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 February 2019
Resolved
FCC Station license expired 10MAR2019. Provide this office with a copy of a valid FCC station License.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2019
Resolution: Vessel owner provided proof of new FCC Station Licens. Updated COI with new Call Sign.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2019
Resolved
The auto-bilge pump located in the Forepeak Compartment is inoperable. Repair or replace and provide this office with proof of proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2019
Resolved 24 October 2019
Resolution: Vessel Owner provided proof of newly installed and operational auto-bilge pump - ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 February 2019
Resolved
Anchor light is inoperable. Provide this office with proof of operational Anchor light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2019
Resolved 24 October 2019
Resolution: Vessel owner provide proof of operational Anchor light - ALL SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 October 2018
Resolved
Any vessel of at least five net tons must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. The vessels Certificate of Documentation onbopard expired 31 May 2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2018
Resolution: Vessel O/Op renewed COD valid 10/24/2018 - 10/31/2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2018
Resolved
Shutoff valves installed as to close against the fuel flow must be fitted in the fuel supply lines. The fuel shutoff valve handle is wasted and broken off.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
Resolution: Vessel O/Op provided electronic picture of repaired shutoff valve ahndle in the open and closed positions.
Communications › Radio Communications › EPIRB
Issued 31 October 2017
Resolved
EPIRB battery expired. Have new battery installed. Vessel restricted to a Lakes,Bays, and Sounds route until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 2 December 2020
Resolution: Battery not expired during 20 October, 2020 inspection (activity 7081877)