MAURY USCG vessel records
← All vessels

BBC PLATA

BBC PLATA is a 2003 public freight. The Coast Guard has recorded 27 inspections since 2016, most recently in March 2026, along with 9 deficiencies and 6 operational controls.

Records from 2016 to 2026. Most recent: inspection, 18 March 2026.

Built
2003
Last inspected
18 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9291975
765900
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-765900

Documentation record

Tonnage as PSIX records it9618 - Convention (Subpart B), Gross Ton
4260 - Convention (Subpart B), Net Ton
17972 - Displacement, Metric Ton
12837 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

18 March 2026 PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8327855
16 March 2026 Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8327149
20 August 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8213996
5 August 2025 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8198532
5 August 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8202873
21 December 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8049926
26 October 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8024973
24 May 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7918508
2 April 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7888966
25 January 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7855380
17 April 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7432452
7 December 2021 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7363819
19 September 2021 PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7311976
15 September 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7313090
14 September 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7312017
9 May 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6950732
21 November 2019 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6860588
6 September 2019 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6805836
28 August 2019 PII Safety Exam · ISPS II Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6787754
22 August 2019 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6795827
20 August 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6511626
24 April 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6389591
27 October 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6296508
10 October 2017 ISPS II Exam · COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6284416
27 July 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6223531
17 February 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6089833
18 January 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5799173

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 March 2026 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed 02 hoses with pin hole leaks and 05 hoses leaking at the coupling.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Reecieved class report attesting to repairs and replacement hoses.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 18 March 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 March 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 August 2025 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. PSCO observed 01 ruptured starting battery for emergency generator starting system. Replace battery and test system to the satisfaction of classification society. 74SOLAS(AMEND)II-1/44.2 60 ac
Action required: 60 - Rectify deficiencies prior to movement
Due 5 August 2025
Resolved 5 August 2025
Resolution: Failed battery was replaced and system tested to the satisfaction of the classification society.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 August 2025 Resolved
A valve shall be fitted to serve each fire hydrant so that any hose may be removed while the fire pumps are in operation. PSCO observed aft deck fire station valve leaking by while emergency fire pump was in operation replace valve to the satisfaction of the certificate issuing authority. 74SOLAS(AMEND)II-2/10.2.1.4.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2025
Resolved 5 August 2025
Resolution: Faulty valve was replaced and system tested to the satisfaction of the classification society.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 19 September 2021 Resolved
WHERE DAVIT ARMS ARE RECOVEREDBY POWER, SAFETY DEVICES SHALL BE FITTED WHICH WILL AUTOMATICALLY CUT OFF POWER BEFORE THE DAVIT ARMS REACHTHE STOPS IN ORDER TO PREVENT OVERSTRESSING THE FALLS OR DAVITS. PSCO OBSERVED LIMIT SWITCH FOR RESCUE BOAT DAVIT NOT OPERATIONAL. CREW FIXED AND TESTED PRIOR TO [name withheld].
Action required: 10 - Deficiency Rectified
Due 19 September 2021
Resolved 19 September 2021
Resolution: CREW REPLACED LIMIT SWITCH PRIOR TO [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 September 2021 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER RESOLUTIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. VESSEL'S CCTV WIRING TO FORWARD CAMERA PENETRATED BULKHEAD OF BOSN STORE. WATER TIGHT INTEGRITY HAS BEEN COMPRIMISED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2021
Resolved 3 December 2021
Resolution: Penetrating piping was removed and holes were welded over. Repairs verified by Class NKK, survey report attached.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2021 Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE OR EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINISTRATION. HYDRAULIC PUMP ESD ON #2 FORWARD HOLD COVER WAS NOT SEALED ALLOWING FLAMMABLE VAPOR TO ACCUMULATE. RECITFIY PRIOR TO CARRYING FLAMMABLE CARGO.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 September 2021
Resolved 3 December 2021
Resolution: Seal for cabling was repaired and verified by Class NKK, survey report is attached.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 21 November 2019 Resolved
All ships 3000GT and upwards shall have an operable 3 GHZ radar. Vessel's S-Band radar is inoperable. SOLAS 74 (2014 Cons.) Reg. V/12
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2019
Resolved 24 November 2019
Resolution: Received technician report attesting to repair and operational condition of s-band radar.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 21 November 2019 Resolved
If during voyage, any navigation equipment required by this part stops operating properly, ther person directing the movement of the vessel may continue to the next port of call subject to the direction of the district commander or the captain of the port zone. Vessel entered captain of the port zone without proper notification of inoperable S-Band radar. 33 CFR 164.55
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
Resolution: Instructed vessel on the proper proceedures for reporting inoperable navigation equipment prior to entry.

Ownership record