MAURY USCG vessel records Sign in
← All vessels

FRONTIER EXPLORER

FRONTIER EXPLORER is a freight ship. The Coast Guard has recorded 27 inspections since 2005, most recently in April 2008, along with 9 deficiencies and 13 operational controls.

Records from 2005 to 2008. Most recent: inspection, 28 April 2008.

Built
Not recorded
Last inspected
28 April 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9118305 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
765974
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-765974

Inspections, by type

…with no type recorded21
Years with a record 4 calendar years (2005–2008)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4183 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

28 April 2008 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3194514
29 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3174376
2 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3140689
2 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3141489
8 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3112008
15 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3060276
11 September 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3055143
16 July 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2995721
11 June 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2958895
31 May 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2948137
30 May 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2946036
28 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2943431
28 May 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2943952
28 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2917927
17 October 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2802233
15 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2800752
11 July 2006 MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2710850
28 June 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2694065
4 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2641242
2 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2639347
11 January 2006 Ballast Water Examination · Deficiency Check · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2542379
25 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2439386
21 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2434191
21 July 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2434602
19 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2432670
19 July 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2432905
6 July 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2417920

Deficiency record · 9

Fire Fighting › Means of Escape › Blocked
Issued 11 July 2006 Resolved
Found temporary flooring leading from engine control room into the engine workshop. Flooring was made of wooden planks, unauthorized in a A60 escape space.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2006
Resolved 11 July 2006
Resolution: Removed wooden planks, freeing space for escape.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 11 July 2006 Resolved
In the port side emergency escape trunk, found 2 emergency lighting failures.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2006
Resolved 11 July 2006
Resolution: Replaced lightbulbs; satisfactory.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 2 December 2005 Resolved
THICK OILY RESIDUE BUILDUP IN THE BILGES, ENGINE ROOM, FIRE HAZARD, CLEAN THE BILGES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2006
Resolved 11 January 2006
Resolution: Attended vessel and observed clean bilges. Deficiency resolved.
Electrical › Electric Generation Source (service) › Generator
Issued 19 July 2005 Resolved
Vessel's ship service generators are inoperable. They will not maintain operation while in sync or parrallel. Make permanent/proper repairs to generators. Have Flag State attest to repairs. Master failed to notify USCG of the hazardous condition that this presented before arriving into port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2005
Resolved 20 July 2005
Lifesaving › Launching Appliances › Ramp (free-fall)
Issued 19 July 2005 Resolved
Master informed CG Inspector that their releasing mechanism fo the free-fall lifeboat was not functioning properly. Master informed that when the lever is pulled, the liefboat does not launch wiouth manual assistance (hitting with a hammer from the outside). Make permanant repairs and successfully launch free-fall lifeboat without assistance.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2005
Resolved 20 July 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 July 2005 Resolved
CG Marine Inspector doubts the validity of the vessel's safety management system. It is requested that a audit be conducted due to deficiencies 1 & 2.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2005
Resolved 20 July 2005
Construction/Loadline › Hull › Weld
Issued 19 July 2005 Resolved
Inside Focsle (BOSN stores), there is a crack on top of the starboard side anchor housing. Have flag State administration provide timeline and proposal for repairs.
Action required: 705 - Other - as specified
Due 20 August 2005
Resolved 20 July 2005
Operations/Management › Drills/Instruction › Fire
Issued 19 July 2005 Resolved
Drills not conducted due to vessel's detention and crew's attempt to repair deficiencies. Conduct fire and rescue boat drills in the presence of a CG Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 July 2005
Resolved 20 July 2005
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 19 July 2005 Resolved
Master failed to notify the USCG about the hazardous condition of the vessel prior to entering port.
Action required: 705 - Other - as specified
Resolved 19 July 2005

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.