← All vessels
MAZURY
MAZURY is a 2005 freight ship. The Coast Guard has recorded 16 inspections since 2005, most recently in October 2023, along with 10 deficiencies and 2 operational controls.
Records from 2005 to 2023. Most recent: inspection, 14 October 2023.
- Built
- 2005
- Last inspected
- 14 October 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9285122 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6TX8
766023
Flag
BAHAMAS, THE
—
Maury page id
psix-766023
Inspections, by type
…with no type recorded3
Years with a record
10 calendar years (2005–2023)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it24109 - Convention (Subpart B), Gross Ton
13253 - Convention (Subpart B), Net Ton
38980 - Dead Weight, Ton
47840 - Displacement, Ton
13253 - Convention (Subpart B), Net Ton
38980 - Dead Weight, Ton
47840 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
14 October 2023
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7806208
29 July 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7012946
20 July 2020
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7002724
28 February 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6363235
15 September 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6001696
13 September 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5994306
23 October 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002150
28 December 2011
ISPS II Exam · COE-Offshore · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4215029
20 October 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3873935
23 February 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3682249
3 July 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2982350
25 March 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2886184
24 July 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2724074
8 July 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2419865
7 July 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2418872
2 July 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2411273
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 July 2020
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO noted all five of the vessel water mist system discharge valves in the closed position. Although system was placed in automatic, in the event of a fire, the closed valves would not have supplied fire-fighting water as designed.
74SOLAS(04) II-2/ 14.1.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 July 2020
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The smoke detection system for all cargo holds was found disconnected from sample points, without following SMS procedures, rendering the system inoperable.
74SOLAS(04)II-2/ 14.1.1
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 July 2020
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO noted four of the emergency generator room ventilation closures were not able to be closed by crew when spot checked during expanded exam.
74SOLAS(04)II-2/ 14.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2020
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO noted the #1 SSDG had excessive oil leaking from the inboard side of the turbo and was actively smoking during spot check of machinery.
74SOLAS(04) II-2/ 4.1.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 20 July 2020
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The COTP questions the adequacy and or implementation of the vessel’s SMS under the ISM Code. An external audit is recommended to be conducted within 30 days by the flag or RO to determine whether the ship is operating in accordance with the ISM Code. Provide decision to USCG prior to departure from port.
74SOLAS(14) XI-1/4.1 ISM Code 10.1
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 July 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed missing hardware on steel deck gratings on top of boiler flat. Further examination revealed the grating was completely disconnected, creating a risk to crew, causing slip, tripping, and falling hazard.
74SOLAS(14) I/ 11(a)
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 20 July 2020
Resolved
After any survey of the ship under regulation 7, 8, 9, 10, has been completed, no change shall be made in the structure, arrangements, machinery , equipment and other items covered by the survey, without the sanction of the administration. During the engine room walk through PSCO noted the smoke detector above the incinerator had been modified. Provide clarification from certificate issuing authority for the arrangement. 74 SOLAS(14) I/11(b)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 July 2020
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks, however hold back arrangements fitted with remote release devices of the fail -safe type may be utilized. PSCO observed the following self-closing doors held open using tie-backs preventing the doors from closing:
1) door leading to the escape trunk in the lower engine room.
2) Door in the engine room leading to incinerator space.
3) Door in the galley leading to provisions space.
74 SOLAS (04) II/2/9.4.2.2
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 July 2020
Resolved
The Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard . PSCO Noted the electrical panel to the boiler unit was held open by a door clip due to overheating of the unit, reported by the chief engineer. 74SOLAS(14) I/11(a)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 July 2020
Resolved
The Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard PSCO Observed self-closing device on door from the galley to provisions store not operating properly.74 SOLAS (14) I/11(a)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.