BEAUTIFUL SWIMMER

BEAUTIFUL SWIMMER is a 1960 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1987, most recently in May 2026, along with 80 deficiencies.

Records from 1987 to 2026. Most recent: inspection, 18 May 2026.

Built
1960
Last inspected
18 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC6246
Flag
UNITED STATES
368327080
Maury page id
psix-76813

Inspections, by type

…with no type recorded1
Years with a record 35 calendar years (1987–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.3 ft × 13.4 ft × 4.7 ft
Registered tonnagegross 17 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAUL L JONES · CROCHERON, MD, UNITED STATES · built 1960
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portROCK HALL, MD
Trade endorsementsFishery
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN9441MMSI 368327080 · active · compulsorily equipped · granted 29 July 2023, expires 29 July 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDC6246MMSI 367053460 · expired · compulsorily equipped · granted 22 May 2015, cancelled 2 August 2025 · licensed under a name not among this hull’s recorded names (not shown)
WAB4200MMSI 366932730 · expired · compulsorily equipped · granted 19 March 2004, cancelled 26 July 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

18 May 2026 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8381117
7 May 2026 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8369103
1 May 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8359184
3 June 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8151670
15 January 2025 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8064025
8 January 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7846328
26 June 2023 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7724018
25 April 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7677172
13 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7447835
10 December 2021 Drydock Exam · Internal Structural Exam · Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7447815
30 March 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7165331
23 April 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6942823
28 March 2019 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6651139
28 November 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6319155
13 July 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6207695
25 April 2017 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132380
28 July 2016 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5955706
19 July 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5947723
21 October 2015 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5752558
10 May 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4307397
20 July 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4109074
25 November 2008 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3389510
2 April 2008 Examination of Repairs · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3176382
22 March 2007 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2886277
11 May 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2655723
1 November 2005 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2525440
13 April 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2348449
22 April 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2050285
22 March 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2033838
17 April 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1790074
11 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1603286
17 April 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1439276
27 March 2001 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1439277
15 May 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1412160
27 April 1999 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1127671
18 March 1999 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 793093
7 January 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809994
12 June 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792766
8 May 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1126033
4 February 1998 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 773459
5 May 1997 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422848
1 May 1996 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1427200
10 April 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1463954
25 October 1995 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 874424
11 May 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1182483
11 May 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1176757
11 April 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1174305
29 April 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422246
26 February 1993 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1135435
12 May 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 952644
6 May 1991 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 956507
18 April 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 920763
5 March 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 995478
7 February 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 903215
8 February 1990 COI Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 930599
23 May 1989 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1340983
13 December 1988 Deficiency Check · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1037197
5 December 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1208308
8 June 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1039673
6 November 1987 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1330480
26 February 1987 Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1330923

Deficiency record · 80

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2026 Resolved
13199 - Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The ventilation for the engine compartment did not close properly. 46 CFR 185.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2026
Resolution: Engine compartment ventilation was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2026 Resolved
13104 - On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual indicator for the high water level alarm was inoperable. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2026
Resolution: The high water level alarm was fixed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 May 2026 Resolved
04108 - The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. There were no emergency instructions on the vessel. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2026
Resolution: Vessel obtained emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 June 2025 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. Life float is no longer is serviceable condition, vessel may not operate with passengers during cold water months 01NOV-15MAY until life float is replaced.
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: Vessel obtained new life float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 January 2025 Resolved
03109 - Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. A positive action valve or cock that is located as close as possible to the hull is an acceptable means for compliance. The handle for the port wash down valve broke off rendering it unable to be opened or closed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2025
Resolution: Verified replacement of ball valve for washdown pump.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 April 2023 Resolved
46CFR160.010(n) - The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED-STD-595C (incorporated by reference, see § 160.010-1 of this subpart. Life float was discolored on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 26 June 2023
Resolution: Vessel owner sent photo of repainted life float.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 April 2023 Resolved
47 CFR 80.13(a) - Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel could not provide evidence that they had a valid ship station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 26 June 2023
Resolution: Owner provided copy of original issued station license for the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2022 Resolved
46 CFR 180.71(a) - An adult life jacket must be provided for each person carried on board a vessel. Vessel's COI requires 25 adult life jackets but vessel only has 21 adult life jackets on board. Vessel is restricted to carry 20 passengers until four additional life jackets are provided.
Action required: 705 - Other - as specified
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 May 2022 Resolved
46 CFR 180.137(d) - If the life float does not have a painter attachment fitting, a means for attaching the painter must be provided. Vessel's painter line for the life float was not properly attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2022 Resolved
46 CFR 185.516(a) - Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are visable to the passengers. Vessel had no life jacket placards posted on board the vessel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 May 2022 Resolved
46 CFR 4.06-15(a) - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel's on board alcohol testing strips were past their expiration date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2022 Resolved
46 CFR 182.520(e)(1) - The submersible electric bilge pump must meet the requirements in UL 1113(incorporated by reference; see 46 CFR 175.600). Vessel's forward bilge pump's float was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
Construction/Loadline › Hull › Bottom Plating
Issued 28 November 2017 Resolved
Vessel's bottom has extensive rot, deterioration and delamination of bottom planking. PRovide a repair proposal addressing bottom replanking or satisfactory equivalent to the satisfaction of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 November 2017
Resolved 1 February 2019
Engineering › Steering Gear System › Rudder
Issued 28 November 2017 Resolved
Vessel's rudder has extensive fracture. Replace rudder with satisfactory equivalent and demonstrate proper operation to the attending MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2017
Resolved 1 February 2019
Construction/Loadline › Hull › Side Shell
Issued 28 November 2017 Resolved
Vessel has approx. 2-3' fracture on portside side sideshell in vicinity of bulwark/gunwalre. Submit repair proposal to local OCMI for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2017
Resolved 1 February 2019
Lifesaving › Lifefloat › Serviceable
Issued 8 May 2017 Resolved
Vessel is limited to warm water operations only. Repair lifefloat IAW manufacturer's recommendations - net attachment points and netting itself.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 February 2019
Documentation › Certificates/Documents › FCC SSL
Issued 8 May 2017 Resolved
Porvide copy of FCC Station Authorization Certificate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 22 May 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 May 2017 Resolved
Provide copy of Drug Policy and post EAP number
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 22 May 2017
Resolution: Provided company drug policy and EAP numbers.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017 Resolved
Obtain proper first aid kit contents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 22 May 2017
Resolution: Proper first aid kit contents provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 July 2016 Resolved
FCC station license expired. Renew and provide copy to attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 28 July 2016
Resolution: Received a copy of FCC Station License via email.
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2016 Resolved
Replace life ring which is wasted along the seam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 28 July 2016
Resolution: Received via email picture of new life ring buoy.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 July 2016 Resolved
Replaced/add Solas retro-reflective tape to life float. Tape should be on both sides.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 28 July 2016
Resolution: eceived via email picture of SOLAS retro-reflective tape properly installed on life float.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2015 Resolved
Vessels First Aid kit eye wash fluid had expired. Replace Eye Wash in kit.
Due 20 November 2015
Resolved 19 July 2016
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifefloat › Platform
Issued 21 October 2015 Resolved
Repair or replace life float basket line that hass wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2015
Resolved 6 November 2015
Resolution: Verified via electronic photograph that the life float basket line had been replaced and in proper condition
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 21 October 2015 Resolved
Repair cracked window in vicinity of the stbd side operating station.
Due 6 December 2015
Resolved 19 July 2016
Resolution: Attended vessel and cleared above deficiency.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 October 2015 Resolved
Vessel has exceeded the three month window for conducting a USCG Annual Inspection as required in 46 CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2015
Resolution: Conducted vessels Annual Inspection
Documentation › Markings/Placards › Oil Discharge Placard
Issued 10 May 2012 Resolved
Discharge of oil placard missing, provide as required.
Due 12 June 2012
Resolved 12 June 2012
Resolution: Discharge of oil placard provided as required.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 May 2012 Resolved
Life Jacket storewage location for adult and children not properly labeled.
Due 12 June 2012
Resolved 12 June 2012
Resolution: Required labeling completed.
Construction/Loadline › Structures › Deck Plating
Issued 25 November 2008 Resolved
Deck is missing 6 inch coam around engine compartment hatch.
Condition: Improper Installation
Due 6 April 2009
Resolved 4 February 2009
Resolution: Vessel owner stated that he would be completing the addition of the 6 inch coaming around his engine space prior to operating in 2009. He submitted plans for coaming installation that were approved. Annual inspection scheduled for first week of April.
Construction/Loadline › Hull › Hull Plating
Issued 25 November 2008 Resolved
Rotted planks were noted at the forward waterline on both the port and starboard sides. Additinally one deadrise plank was plank near amidships on the starboard side of the vessel.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2008
Resolution: Owner hired a marine carpenter to replace all rotten frames.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 November 2008 Resolved
[name withheld] was noted in the aft space behind and adjacent to the engine space. Owner was informed that he needed to remove angel hair, treat wood with preservative, and look into adding ventilation to his vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 3 December 2008
Resolution: Owner removed angel hair and treated internal structures with wood preservative.
Construction/Loadline › Hull › Keel
Issued 2 April 2008 Resolved
Noted water running in on stem at water line while underway. Repair/make water tight prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2008
Resolved 14 April 2008
Resolution: Conducted U/W sea trial and cleared above deficiency.
Construction/Loadline › Hull › Keel
Issued 2 April 2008 Resolved
Noted water running of the top of a keel repair in way of the rudder post/not from the post. Remove repair to determine the reason for leak and repair keel/rudder post area by appropriate 12/1 scarf of the keel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2008
Resolved 14 April 2008
Resolution: Conducted U/W sea trial and cleared above deficiency.
Engineering › Steering Gear System › Piping
Issued 2 April 2008 Resolved
Rudder post fractured. Renew rudder stock as original.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2008
Resolved 14 April 2008
Resolution: Examined rudder post, no deficiencies noted, cleared above deficiency.
Engineering › Steering Gear System › Bracket/Clamp
Issued 2 April 2008 Resolved
Rudder post assembly wasted. Renew as original.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2008
Resolved 14 April 2008
Resolution: Examined rudder post assembly, no deficiencies noted.
Construction/Loadline › Hull › Keel
Issued 2 April 2008 Resolved
Permanent repairs to the keel will be completed prior to 30 November 2008.
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 25 November 2008
Resolution: Rudder shaft, bearing, and keel bolts where all replaced in accordance with the approved repair submittal. Rotted wood in the Keel was cropped out and replaced with a custom designed scarf joint in order to accomodate the specific design of the vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 April 2007 Resolved
Required 2 hour drug test kit onboard or ltr stating arrangement from a facility have been made to meet the requirement.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 25 April 2007
Resolution: Rcvd faxed copy of test kit. When in Cheaspeake Beach will visit vsl to verify.
Lifesaving › Lifefloat › Float-free Link
Issued 5 April 2007 Resolved
Provide proof of weak link beingcertified and proper size.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 12 April 2007
Resolution: O/O had purchased new weak link. On visit to vsl sighted new weak link.
Engineering › Bilge Water Management System › Pump
Issued 5 April 2007 Resolved
Bilge pump in fwd compartment needs to be secured in place.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 12 April 2007
Resolution: Inspected bilge pump on 14apr2007.
Engineering › Bilge Water Management System › Pump
Issued 11 May 2006 Resolved
Bilge pump in engine compartment not operating. Repair/replace. Label all bilge and High water alarm indicators. One indicator for each.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 9 June 2006
Resolution: Received fax from O/Op that bilge pump had been repaired.
Documentation › Certificates/Documents › FCC SSL
Issued 1 November 2005 Resolved
Provide on board current FCC safety certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 19 December 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 November 2005 Resolved
Replace grabline on ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 19 December 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 November 2005 Resolved
Provide proof of membership in an alcohol and drug program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 19 December 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 November 2005 Resolved
Provide proof of portable and fixed fire fighting systems annual servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 19 December 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 1 November 2005 Resolved
Provide on board current tide tables for operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 19 December 2005
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 1 November 2005 Resolved
Repair shaft coupling which is leaking excessively.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 19 December 2005
Construction/Loadline › Hull
Issued 22 March 2004 Resolved
Remove angel hair on longitudinal in lazarette.
Due 25 April 2004
Resolved 22 April 2004
Construction/Loadline
Issued 22 March 2004 Resolved
Remove angel hair on longitudinal in space forward of engine room.
Due 25 April 2004
Resolved 22 April 2004
Construction/Loadline
Issued 22 March 2004 Resolved
Renew overhead aft supports.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2004
Resolved 22 April 2004
Construction/Loadline
Issued 22 March 2004 Resolved
Renew deck support stbd side near engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2004
Resolved 22 April 2004
Construction/Loadline
Issued 22 March 2004 Resolved
Renew deck support port aft engine area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2004
Resolved 22 April 2004
Lifesaving › Buoyant Apparatus
Issued 17 April 2003 Resolved
Lash lifefloat paddles to life float
Due 17 May 2003
Resolved 6 May 2003
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 April 2003 Resolved
Close sewage overboard discharge valve and remove handle.
Due 17 May 2003
Resolved 6 May 2003
Navigation
Issued 8 May 1998 Resolved
PROVIDE UP-TO-DATE CHART OF OPERATING AREA.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Engineering
Issued 8 May 1998 Resolved
CONDUCT UNDERWAY TEST OF MDE.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 8 May 1998 Resolved
CONDUCT MOB DRILL.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Construction/Loadline
Issued 8 May 1998 Resolved
CAP UNUSED THROUGH HULL VALVE IN STERN PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Electrical
Issued 1 May 1996 Resolved
The wiring to the bilge indicator light, bilge high level light and the loran are improper. All used less than 14 awg wire._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 14 May 1996
Navigation
Issued 1 May 1996 Resolved
The radar is inoperable._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 14 May 1996
Electrical
Issued 1 May 1996 Resolved
Wing nuts were used to connect the loran directly to the port battery._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 14 May 1996
Navigation
Issued 1 May 1996 Resolved
The fittings on the 2 hydraulic lines to the steering ram are badly corroded._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 14 May 1996
Unknown
Issued 1 May 1996 Resolved
Need to conduct an underway operational test and drills._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 14 May 1996
Lifesaving
Issued 1 May 1996 Resolved
The life line around the ring bouy was badly deteriorated._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 14 May 1996
Engineering
Issued 7 February 1991 Resolved
PERFORM UNDERWAY TEST IN PRESENCE OF MARINE INSPECTOR PRIOR TO 7APR91
Condition: Unknown
Due 7 February 1991
Resolved 7 February 1991
Fire Fighting
Issued 7 February 1991 Resolved
SERVICE ALL FIRE EXTINGUISHERS PRIOR TO0 CARRYING PASSENGERS. UPON _x001C_ COMPLETION, SUBMIT RECEIPT OF SAME USCG (MSO BALTO)
Condition: Unknown
Due 7 February 1991
Resolved 7 February 1991
Navigation
Issued 23 May 1989 Resolved
PROVIDE CURRENT DOCUMENTATION CERTIFICATE
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Navigation
Issued 23 May 1989 Resolved
POST STABILITY LETTER
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Lifesaving
Issued 23 May 1989 Resolved
PAINT VESSEL NAME ON LIFEFLOAT PADDLES
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Accommodation/Occupational Safety
Issued 8 June 1988 Resolved
CHAIN AND LOCK THE MSD OVERBOARD DISCHARGE VALVE IN THE CLOSED POSITION.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988 Resolved
PROVIDE AN UNDERWAY OPERATIONAL EXAM WITH THE CG IN ATTENDANCE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Navigation
Issued 8 June 1988 Resolved
PROVIDE THE FOLLOWING PUBLICATIONS: CHARTS WHICH ARE LESS THAN 3 YRS OLD; RULES OF THE ROAD, AND SMALL PASSENGER VESSEL REGULATIONS (46CFR 175-187).
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Documentation
Issued 8 June 1988 Resolved
PROVIDE AN FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Engineering
Issued 8 June 1988 Resolved
LABEL FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988 Resolved
REPLACE HOSE ON THE FORWARD AND AFTER BILGE PUMP WITH HOSE THAT IS OIL RESISTANT AND REINFORCED.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Electrical
Issued 8 June 1988 Resolved
LINE BATTERY BOXES WITH LEAD OR FIBERGLASS.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Lifesaving
Issued 8 June 1988 Resolved
PROVIDE PADDLES WHICH ARE AT LEAST 4' LONG FOR THE LIFE FLOAT.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Fire Fighting
Issued 8 June 1988 Resolved
SERVICE THE HALON FIXED FIRE EXTINGUISHER.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 26 February 1987 Resolved
PROVIDE FUEL SHUT-OFF VALVE IN WAY OF FUEL LINE ON ENGINE SIDE OF LOWER FUEL FILTER.
Condition: Unknown
Due 26 February 1987
Resolved 26 February 1987
Unknown
Issued 26 February 1987 Resolved
PROVIDE SIX RED DISTRESS SIGNALS OF CURRENT DATE/STATUS.
Condition: Unknown
Due 26 February 1987
Resolved 26 February 1987
Unknown
Issued 26 February 1987 Resolved
PROVIDE ONE APPROVED WATERLIGHT FOR THE BUOYANT APPARATUS.
Condition: Unknown
Due 26 February 1987
Resolved 26 February 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.