Records from 2016 to 2026. Most recent: inspection, 18 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 18
18 May 2026
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8381117
7 May 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8369103
1 May 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8359184
3 June 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8151670
15 January 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8064025
8 January 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7846328
26 June 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7724018
25 April 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7677172
13 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7447835
10 December 2021
Drydock Exam · Internal Structural Exam · Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7447815
30 March 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7165331
23 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6942823
28 March 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6651139
28 November 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6319155
13 July 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6207695
25 April 2017
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132380
28 July 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5955706
19 July 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5947723
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2026
Resolved
13199 - Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The ventilation for the engine compartment did not close properly.
46 CFR 185.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2026
Resolution: Engine compartment ventilation was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2026
Resolved
13104 - On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual indicator for the high water level alarm was inoperable.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2026
Resolution: The high water level alarm was fixed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 May 2026
Resolved
04108 - The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. There were no emergency instructions on the vessel.
46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2026
Resolution: Vessel obtained emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 June 2025
Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. Life float is no longer is serviceable condition, vessel may not operate with passengers during cold water months 01NOV-15MAY until life float is replaced.
Action required: 705 - Other - as specified
Resolved 18 May 2026
Resolution: Vessel obtained new life float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 January 2025
Resolved
03109 - Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. A positive action valve or cock that is located as close as possible to the hull is an acceptable means for compliance. The handle for the port wash down valve broke off rendering it unable to be opened or closed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2025
Resolution: Verified replacement of ball valve for washdown pump.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 April 2023
Resolved
46CFR160.010(n) - The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED-STD-595C (incorporated by reference, see § 160.010-1 of this subpart. Life float was discolored on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 26 June 2023
Resolution: Vessel owner sent photo of repainted life float.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 April 2023
Resolved
47 CFR 80.13(a) - Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel could not provide evidence that they had a valid ship station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2023
Resolved 26 June 2023
Resolution: Owner provided copy of original issued station license for the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2022
Resolved
46 CFR 180.71(a) - An adult life jacket must be provided for each person carried on board a vessel. Vessel's COI requires 25 adult life jackets but vessel only has 21 adult life jackets on board. Vessel is restricted to carry 20 passengers until four additional life jackets are provided.
Action required: 705 - Other - as specified
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 May 2022
Resolved
46 CFR 180.137(d) - If the life float does not have a painter attachment fitting, a means for attaching the painter must be provided. Vessel's painter line for the life float was not properly attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2022
Resolved
46 CFR 185.516(a) - Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are visable to the passengers. Vessel had no life jacket placards posted on board the vessel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 May 2022
Resolved
46 CFR 4.06-15(a) - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel's on board alcohol testing strips were past their expiration date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2022
Resolved
46 CFR 182.520(e)(1) - The submersible electric bilge pump must meet the requirements in UL 1113(incorporated by reference; see 46 CFR 175.600). Vessel's forward bilge pump's float was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2022
Resolution: Vessel owner sent in photo and video evidence to the satisfaction of the CG Marine Inspector to clear the following deficiencies
Construction/Loadline › Hull › Bottom Plating
Issued 28 November 2017
Resolved
Vessel's bottom has extensive rot, deterioration and delamination of bottom planking. PRovide a repair proposal addressing bottom replanking or satisfactory equivalent to the satisfaction of the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 November 2017
Resolved 1 February 2019
Engineering › Steering Gear System › Rudder
Issued 28 November 2017
Resolved
Vessel's rudder has extensive fracture. Replace rudder with satisfactory equivalent and demonstrate proper operation to the attending MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2017
Resolved 1 February 2019
Construction/Loadline › Hull › Side Shell
Issued 28 November 2017
Resolved
Vessel has approx. 2-3' fracture on portside side sideshell in vicinity of bulwark/gunwalre. Submit repair proposal to local OCMI for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2017
Resolved 1 February 2019
Lifesaving › Lifefloat › Serviceable
Issued 8 May 2017
Resolved
Vessel is limited to warm water operations only. Repair lifefloat IAW manufacturer's recommendations - net attachment points and netting itself.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 February 2019
Documentation › Certificates/Documents › FCC SSL
Issued 8 May 2017
Resolved
Porvide copy of FCC Station Authorization Certificate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 22 May 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 May 2017
Resolved
Provide copy of Drug Policy and post EAP number
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 22 May 2017
Resolution: Provided company drug policy and EAP numbers.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017
Resolved
Obtain proper first aid kit contents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 22 May 2017
Resolution: Proper first aid kit contents provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 July 2016
Resolved
FCC station license expired. Renew and provide copy to attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 28 July 2016
Resolution: Received a copy of FCC Station License via email.
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2016
Resolved
Replace life ring which is wasted along the seam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 28 July 2016
Resolution: Received via email picture of new life ring buoy.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 July 2016
Resolved
Replaced/add Solas retro-reflective tape to life float. Tape should be on both sides.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 28 July 2016
Resolution: eceived via email picture of SOLAS retro-reflective tape properly installed on life float.