MOONDANCE II is a 2005 freight ship. The Coast Guard has recorded 15 inspections since 2005, most recently in March 2024, along with 12 deficiencies and 4 operational controls.

Records from 2005 to 2024. Most recent: operational control imposed, 1 March 2024.

Built
2005
Last inspected
1 March 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9316191 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
768871
Flag
LIBERIA
—
Maury page id
psix-768871

Inspections, by type

…with no type recorded6
Years with a record 8 calendar years (2005–2024)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30988 - Convention (Subpart B), Gross Ton
18171 - Convention (Subpart B), Net Ton
64449 - Displacement, Metric Ton
55566 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

1 March 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7868677
22 August 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7773969
18 May 2022 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7448288
14 February 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6348939
8 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6351970
8 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6352232
2 August 2011 PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4101965
28 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4097220
27 January 2009 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3396538
23 December 2007 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3108738
18 January 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2857776
14 July 2005 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2424086
12 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2424590
12 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2430614
8 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2420207

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2024 Resolved
PSCO observed local water mist valve closed. After crew opened valve, PSCO observed water leaking from 02 solenoid. Valve and faulty valve over incinerator and 01 nozzle not working.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 March 2024
Resolution: Received sat class report attesting to repairs made.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 18 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The valve for the anchor wash on starboard side was observed to be broken by the [name withheld] stated the valve broke when securing the anchor wash on the way into the harbor.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 22 August 2023
Resolution: Visual confirmation received of the rectification of deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 14 February 2018 Resolved
1410 (Main engine) Means shall be provided to control leaks of flammable liquids. PSCO observed leaking fuel pumps on the 2, 4, & 6 cylinders of the main engine. SOLAS 74(a) 2014cons. II-2/4.1.1 60 a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 February 2018
Resolved 15 February 2018
Resolution: PSC NOLA recieved class report from DNV-GL attesting to repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 2 August 2011 Resolved
1400: Main diesel engine has excessive fuel leaks. Leakage coming from cylinders #2 and #3. In addition double-jacketed fuel lines have ruptured causing leakage. SOLAS 09 II-2/4.1.1; II-2/4.2.2.5.2, 60ab
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 3 August 2011
Resolution: Repairs verified by Class
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 2 August 2011 Resolved
0710: The fire integrity of the division shall be maintained at openings and penetrations. The crew has made a homemade cover over the engine room skylight which impedes the closure of the hatch. SOLAS 08 II-2/9; 17ab
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2011
Resolved 4 August 2011
Resolution: Received class report attesting to satisfactory repairs.
Lifesaving › Launching Appliances › Winch Brake
Issued 2 August 2011 Resolved
0600: Strb Lifeboat brake/winch has been leaking oil for some time. C/E reported the problem to superintendant. Superintendent sent seals and other items to be replaced. C/E replaced items but system still leaking. During lowering/recovering of lifeboat, brake failed to hold and had to be pushed down by crew to engage. SOLAS 09 III/20; ISM IX/5; ISM A 9/10; 17ab
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2011
Resolved 4 August 2011
Resolution: Received class report attesting to proper repairs.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 2 August 2011 Resolved
0100: Ballast water handling log form not being used, crew training as per part 5 of plan hasn't been carried out, sampling points as per IMO Resolution 868 haven't been identified. It appears the C/O is unfamiliar with Plan and lacks the desire to address problems. 33 CFR 151.2035(a)(7); 17ab
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2011
Resolved 4 August 2011
Resolution: Received class report attesting to the rectification of the deficiency.
Engineering › Steering Gear System › Pump
Issued 2 August 2011 Resolved
1400: Steering reservoir tank is not filled to refill one unit. Non-slip surface is also missing from E/R door to control station. SOLAS 09 II-1/29.12.3; SOLAS 09 II-1/29.13.2; 17ab
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2011
Resolved 4 August 2011
Resolution: Received class report attesting to the satisfactory repairs.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 August 2011 Resolved
1000: Alarm systems shall be provided indicating any fault requiring attention. Audible/visual alarms in steering room and E/R were inoperable during testing. Shields did not rotate. Lamps were extinguished and crew had no spares. SOLAS 09 II-1/51; 70ab
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2011
Resolved 4 August 2011
Resolution: Received class report attesting to satisfactory repairs.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 August 2011 Resolved
2055: SOLAS Training Manual Section 12 and Fire Training Manual Section (f) not filled in. These are required to make items ship specific. SOLAS 09 III/35.3; 70ab
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2011
Resolved 4 August 2011
Resolution: Received class report attesting to the rectification of deficiencies.
Operations/Management › Drills/Instruction › Fire
Issued 2 August 2011 Resolved
2020: Crew failed first fire drill. Crew failed to don fire suits properly, fire boundaries were not established and crew failed to use company check list during drill. Discussed items with crew. Second drill was held satisfactory. SOLAS 09 III/19.3.4; 10c
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 2 August 2011
Resolution: Corrected on the spot.
Lifesaving › Immersion Suits › General
Issued 2 August 2011 Resolved
0663: When crew donned immersion suits, it was discovered that 80% of the crew didn't have the correct size. Bags were incorrectly marked for suits inside. CG personnel had all crewmembers don suits to ensure correct sizes were onboard and issued properly. Safety officer has failed for last 8 months to ensure safety of crew. SOLAS 09 III/7.3, ISM 1.2.1; 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 2 August 2011
Resolution: Corrected on the spot.