MAURY USCG vessel records Sign in
← All vessels

ERIKOUSSA

ERIKOUSSA is a 2005 freight ship. The Coast Guard has recorded 17 inspections since 2005, most recently in December 2019, along with 10 deficiencies and 10 operational controls.

Records from 2005 to 2019. Most recent: operational control imposed, 10 December 2019.

Built
2005
Last inspected
10 December 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9291092 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
768877
Flag
LIBERIA
—
Maury page id
psix-768877

Inspections, by type

…with no type recorded7
Years with a record 9 calendar years (2005–2019)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38871 - Convention (Subpart B), Gross Ton
25194 - Convention (Subpart B), Net Ton
75744 - Dead Weight, Metric Ton
85576 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

10 December 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Appeal
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6870827
9 December 2019 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6869687
8 December 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6869400
28 January 2018 ISPS II Exam · Deficiency Check · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6341945
5 April 2017 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6118070
7 April 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5823402
20 February 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3949001
27 January 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3933958
6 May 2009 MARPOL Annex VI Survey · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · COE-Dockside · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3464632
18 March 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2890059
6 March 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2596605
17 February 2006 ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2584870
17 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2587319
10 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2583171
14 July 2005 Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2427443
11 July 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2423143
10 July 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2421219

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 December 2019 Resolved
07106 - Fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The smoke and flame detectors above the #1 f/o purifier were covered by crew for 9 days following 01DEC19 maintenance on the #1F/O purifier to avoid nuisance alarms. 74SOLAS(14)II-2/14.2.1.1.2
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 10 December 2019
Resolved 11 December 2019
Resolution: Covers removed, smoke and flame detectors tested and found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 10 December 2019 Resolved
04102 - The total suction head and net positive suction of the emergency fire pump shall be determined considering pump capacity and hydrant pressure under all conditions of list, trim, roll, and pitch likely to be encountered in service. Emergency fire pump had to be manually primed by ships crew to attain suction while in ballasted condition. 74 SOLAS (14)II-2/10.2.2.3.1.2
Action required: 30 - Ship detained
Due 10 December 2019
Resolved 11 December 2019
Resolution: Self priming vacuum pump of emergency fire pump has been overhauled and tested satisfactorly.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 December 2019 Resolved
07126 - Means shall be provided to control leaks of flammable liquids. Fuel oil leaks were observed on f/o transfer pump, f/o valve to #4 f/o tank, and main engine, with excessive oil found in the bilge astern of the main engine and below the f/o transfer pump. Lagging in vicinity of leaks found oil soaked. 74 SOLAS (14) II-2/4.1.1
Action required: 30 - Ship detained
Due 10 December 2019
Resolved 11 December 2019
Resolution: Fuel oil transfer pump shaft seal packing renewed, no.4 fuel oil tank port valve spindle packing retightened and main engine bilges cleaned. Soaked lagging has been renewed. All inspected satisfactorly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2019 Resolved
11117 - Two lifebuoys with lights and self-activating smoke signals capable of quick release from the navigation bridge shall be stored port and starboard. Both port and starboard quick-release lifebuoys were not equipped with self-activating smoke signals and attached lights could not be shown to work. 74SOLAS(14)III/7.1.3; LSA Code 2.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2019
Resolved 11 December 2019
Resolution: two self activating smoke signals with attached lights have been supplied onboard and fitted satisfactorly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 December 2019 Resolved
11199 - All lifesaving appliances and arrangements shall comply with the applicable requirements of the Code(LSA). When davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arm reach the stop. PSCO observed the starboard limit switch on the davit arm was heavily corroded. while it did activate the stop as required, it had to be manipulated by hand in order to allow the recovery of the lifeboat. 74SOLAS(14)III/34; LSA Code 6.1.2.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 11 December 2019
Resolution: Starboard limit switch has been renewed, tested and found satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 10 December 2019 Resolved
Due to the obove objective evidence, the PSCO questions the adequacy of the implementation of the vessel's safety management system. Recommend an external ISM audit by the flag or recognized orginization. 74SOLAS(14) IX/3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 11 December 2019
Resolution: Class survey report indicates that external audit will be carried out by 01/10/2020.
Navigation › Piloting/Steering › Marine Charts
Issued 28 January 2018 Resolved
1560-Navigation, Charts- All ships, irrespective of size, shall have nautical charts and nautical publications to plan and display the ship's route for the intended voyage and to plot and monitor positions throughout the voyage. Ship's SMS states that current charts will be provided and passage planning must use all available information prior to sailing. PSCO observed no charts for the Lower Mississippi River onboard. 74SOLAS (am) 2014 cons. V/19.2.1.4, 60a.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2018
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating the deficiency was rectified. All charts required purchased and received on board.
Operations/Management › Pollution › Control of Garbage
Issued 28 January 2018 Resolved
2120-Garbage- Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting, storing, processing and disposing of garbage. PSCO observed garbage stored in the steering gear room, an area not authroized for garbage storage by the garbage management plan. No plan exists to discharge garbage in the current port and insufficient storage exists onboard for garbage accumulation over the next voyage of 61 days. MARPOL Annex V/9.2, 17a.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2018
Resolution: Received, reviewed and accepted proper documentation from Trash Doctors, LLC. stating the deficiency was rectified. Receipt confirms 3 super sacks of garbage removed from vessel.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 28 January 2018 Resolved
0999- Other (Safety in general)- Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed hold-backs for A-60 self-closing doors in the galley. 74SOLAS (am) 2014 cons. II-2/9.4.2.2, 10c.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 January 2018
Resolved 28 January 2018
Resolution: Hold-backs were removed immediately.
Lifesaving › Lifeboat › Rigid Cover
Issued 5 April 2017 Resolved
The condition of the ship and equipment shall be maintained to conform with the present regulations to ensure the ship is fit to proceed to sea. Both lifeboats were found with hull damage at the hand rails. 74SOLAS(14)I/11. 40A.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 April 2017
Resolved 28 January 2018
Resolution: During PSC exam, lifeboats were observed in good condition. Repair report provided.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.