MAURY USCG vessel records Sign in
← All vessels

CHEMTRANS POLARIS

CHEMTRANS POLARIS is a 2005 tank ship. The Coast Guard has recorded 57 inspections since 2005, most recently in April 2024, along with 28 deficiencies and 22 operational controls.

Records from 2005 to 2024. Most recent: inspection, 17 April 2024.

Built
2005
Last inspected
17 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9308998 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
768913
Flag
LIBERIA
—
Maury page id
psix-768913

Inspections, by type

…with no type recorded28
Years with a record 16 calendar years (2005–2024)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it40682 - Convention (Subpart B), Gross Ton
20376 - Convention (Subpart B), Net Ton
72292 - Dead Weight, Metric Ton
86148 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 57

17 April 2024 COC-TVE Renew · PSC B · COE-Dockside
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7895335
4 April 2024 Appeal
Administrative · Commandant (CG-CVC) · Activity 7889889
14 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7865453
2 February 2024 Deficiency Check · In-Service Inspection · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7860058
17 December 2023 Administrative Inspection · COE-Administrative · PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7839873
9 December 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7836836
28 December 2022 PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7613006
8 January 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7376642
10 November 2021 COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7348585
5 November 2019 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6847077
27 August 2018 COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6524150
9 April 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6378777
3 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6384295
26 March 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6378950
10 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6171074
5 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6166029
4 April 2017 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6117691
4 April 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6117854
4 April 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6188241
18 March 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6107239
20 January 2017 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6072040
21 March 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5837164
11 January 2016 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5795195
24 December 2015 COE-Dockside · Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5768855
28 October 2014 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5013139
3 October 2010 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3862001
7 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3453148
2 March 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3426534
1 February 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3403537
31 January 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3403331
29 December 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3386215
22 November 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3367653
22 October 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3349356
22 August 2008 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3292962
2 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3254780
20 May 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3212377
13 July 2007 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2993987
29 May 2007 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2944647
22 April 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2912769
21 April 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2912337
20 July 2006 Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Annual · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2718486
26 May 2006 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2659687
8 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2598569
4 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2596438
2 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2545082
23 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2540239
23 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2557633
2 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2528144
30 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2504609
30 September 2005 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2505007
27 September 2005 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2502263
30 August 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2494854
17 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2466543
14 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2432050
14 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2449169
13 July 2005 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2423977
12 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2439525

Deficiency record · 28

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 February 2024 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENURE THAT THE SHIP IS MAINTAINED CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS... ESTABLISHED BY THE COMPANY. THE TECHNICAL AND OPERATIONAL NATURE OF THE DEFICIENCIES NOTED BELOW PROVIDE OBJECTIVE EVIDENCE OF A SERIOUS FAILURE OF THE IMPLEMENTATION OF THE ISM CODE. AN EXTERNAL AUDIT REPORT SATISFACTORY TO THE OCMI MUST BE SUBMITTED PRIOR TO CLEARANCE OF THIS DEFICIENCY. 74 SOLAS (2020 CONS.)IX/3.1 ISM CODE 10.1 (30ac)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 9 February 2024
Resolution: External Audit Received
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 February 2024 Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO LIMIT THE ACCUMULATION OF FLAMMABLE VAPOURS. PSCO OBSERVED CARGO VACUUM SYSTEM DRAIN LINE IS WASTED AND LEAKING CARGO VAPORS ONTO THE DECK AT THE STARBOARD SIDE PUMPROOM ENTRANCE.PROVIDE MITIGATION PLAN PRIOR TO CARGO OPERATIONS. 74 SOLAS (2020 CONS.)II-2/4.1.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: PSCO observed that the pipe has been replaced with new piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 February 2024 Resolved
WHERE CABLES ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE OR EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED BROKEN WIRE WRAPPED IN ELECTRICAL TAPE ON CARGO LINE 1 & 2 PRESSURE TRANSMITTER BOX AND THE NO. 2 IGS BLOWER IN THE E/R. PERMANENT REPAIR IS REQUIRED PRIOR TO CARGO OPERATIONS. 74 SOLAS (2004 CONS.)II-1/45.5.4 (17ac)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2024
Resolution: Class Report submitted and approved 13Feb2024.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 February 2024 Resolved
A TANK VESSEL WITH A CAPACITY OF 250 OR MORE BARRELS THAT IS CARRYING OIL OR HAZARDOUS MATERIAL AS CARGO MUST HAVE A MEANS OF DRAINING OR REMOVING DISCHARGED OIL OR HAZARDOUS MATERIAL FROM EACH CONTAINER OR ENCLOSED DECK AREA WITHOUT DISCHARGING THE OIL OR HAZARDOUS MATERIAL INTO THE WATER. PSCO OBSERVED THAT THE FIXED DRAIN PIPING CONNECTING THE PORT AND STARBOARD MANIFOLD CONTAINMENT IS CORRODED AND HAS HOLES AT THE CROSS-DECK PIPING.PROVIDE MITIGATION PLAN PRIOR TO CARGO OPERATIONS. 33 CFR 155.310(a)(2)(17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2024
Resolution: Class report submitted and approved 13Feb2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 February 2024 Resolved
THERMAL INSULATION OF BOUNDARIES SHALL HAVE DUE REGARD TO THE FIRE RISK OF THE SPACE AND ADJACENT SPACES. PSCO OBSERVED THERMAL INSULATION REQUIRED FOR STEERING GEAR ROOM OVERHEAD WAS MISSING. 74 SOLAS (2020 CONS.)II-2/9.1.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2024
Resolution: Class Report submitted and Approved 13Feb2024.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 6 February 2024 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED MULTIPLE EEBDS NOT IN COMPLIANCE WITH ONBOARD SMS PROCEDURES AND NOT IN THE LOCATIONS REQUIRED BY THE FIRE CONTROL PLAN. 74 SOLAS (2020 CONS.)II-2/14.2.1.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: Proof of new EEBDs on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 February 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: Smoke signals were replaced on both lifeboats.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2024 Resolved
CRUDE OIL WASHING INSTALLATION AND ASSOCIATED EQUIPMENT AND ARRANGEMENTS SHALL COMPLY WITH THE REQUIREMENTS ESTABLISHED BY THE ADMINISTRATION. PSCO OBSERVED HYDRAULIC OIL LEAKING FROM A VALVE ON COW SYTEM PIPING IN CARGO PUMPROOM. 73 MARPOL (2022)I/33.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: Gaskets in valves were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 February 2024 Resolved
MANHOLES AND FLUSH SCUTTLES IN POSITION 1 OR 2... SHALL BE CLOSED BY SUBSTANTIAL COVERS CAPABLE OF BEING MADE WATERTIGHT. UNLESS SECURED BY CLOSELY SPACED BOLTS, THE COVERS SHALL BE PERMANENTLY ATTACHED. PSCO OBSERVED PORT SIDE NO. 1 HEAVY FUEL OIL EXPANSION TANK DOME HATCH COVER WAS MISSING A DOG AND STARBOARD SIDE NO. 1 BALLAST TANK FLUSH DECK HATCH WAS MISSING A BOLT. ICLL (88 PROT.)REG. 18 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: Bolts and dogs were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2024 Resolved
ALL LIFE SAVING APPLIANCES AND ARRANGEMENTS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CODE. PSCO OBSERVED LIFEBUOY ON PORT SIDE MIDSHIP WAS MISSING RETRO-REFLECTIVE MATERIAL. 74SOLAS (2020 CONS.) III/34 LSA CODE 1.2.2.7 (10C)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 February 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2024 Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED A CORRODED HEAD TANK ON STRIPPING LINE VALVE THAT LEAKS OIL INTO CARGO PUMPROOM. 74 SOLAS(2020 CONS.) II-2/4.1.1 (10C)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 February 2024
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 2 February 2024 Resolved
The venting arrangements shall be so designed and operated as to ensure that neither pressure nor vacuum in cargo tanks shall exceed design parameters. The PSCO found additional hardware stacked on the pressure adjustment bolt of the #4P P/V valve. Additionally, the #3P P/V valve was found frozen (rusted) in the closed position. 74SOLAS(20) II-2/11.6.1 action code 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Coast Guard verified repairs noted on class report
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 2 February 2024 Resolved
The means to stop the flow of cargo must perform its intended function. The emergency shutdown controls did not rapidly secure the cargo pump revolutions, additionally the cargo pump tachometers functioned erratically upon cargo pump emergency shutdown. 33CFR156.170(c)(5) action code 17ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 April 2024
Resolution: PSCO accepted class report and observed emergency shutdown tachometer operating as designed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 February 2024 Resolved
All hatchways in position 1 shall be fitted with hatch covers of steel. Such covers shall be weather tight and fitted with gaskets and clamping devices. A possible patch was detected in the vicinity of hatch #2DB WBT immediately port side of center walkway. 1966 ICLL (1988 Protocol) 16.1 action code 17ac.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Coast Found that metal blind flange was not a patch. It was a metal plate that rusted to the deck and has been removed. See class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 2 February 2024 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO's observed all hydraulic valve boxes on deck leaking hydraulic fluid. 74SOLAS(20) I-11 action code 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Coast Guard verified repairs noted on class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 2 February 2024 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO's observed hydraulic power units for remote control valves leaking hydraulic fluid. 74SOLAS(20) I-11 action code 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Coast Guard verified repairs noted on class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2023 Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION IN ACCORDANCE WITH THE PROVISIONS OF REGULATION XI/1 OR WITH APPLICABLE NATIONAL STANDARDS OF THE ADMINISTRATION WHICH PROVIDE AN EQUIVALENT LEVEL OF SAFETY.PSCO OBSERVED BALLAST WATER LEAK ON BALLAST WATER PUMP #1 ON THE SHAFT SEAL. 74SOLAS(04)II-I/3-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2024
Resolved 16 February 2024
Resolution: Recieved appropriate Class documentation. Entered into Documents Tab. All Satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 January 2022 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between bolt holes, and in line with the bolt hole pattern. PSCO observed 3 out of the 4 vapor connections stud are temporary stubs and the four stub is welded to the vapor connection and flange making it incapable of usage. 46 CFR 39.2001
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2022
Resolution: Vessel submitted class report stating VCS system was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 January 2022 Resolved
SOLAS: Starting and operating the lifeboat engine. LSA: The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. PSCO observed that the PORT rescue boat engine would not start. Due to the batteries in the rescue needing to be charged. 74 SOLAS 20 III/19.3.4.1.6 LSA/4.4.6.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 January 2022
Resolution: Vsl repaired rescue boat prior to exam team leaving the ship.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2021 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and constructed adequate for the service for which they are intended. PSCO observed jacket water leaking from #3 cylinder of main diesel engine. SOLAS II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 November 2021
Resolution: Received,reviewed and accepted LR Class report Statement#2134893. #3 Main engine cyl. liner was pulled by ships crew. J/W O-rings were replaced by spares onboard and reassembled. Visual inspection carried out on additional cylinders.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 24 December 2015 Resolved
1740- MARPOL I/31.1 Oil Tankers of 150 GT and above shall be equipped with an oil discharge monitoring device and control sysytem approved by the administration. The crew was unable to conduct a performance test during the exam.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2016
Resolution: Provided class report indicating training was conducted and crew proficiency verified
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 December 2015 Resolved
2550-ISM/10.1 The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and reg. and w/ any additional req. which may be established by the company; PSCO identified multiple pieces of malfunctioning equipment; Recommend ISM external ISM audit.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2016
Resolution: Recieved class report that all equipmnet was functioning properly
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 24 December 2015 Resolved
0999- 33CFR155.480 On a tankship, each cargo tank must be equipped with an overfill device including an independent audible and visual alarm; vessel's 1P cargo tank alarm wasn't functional
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2015
Resolved 24 December 2015
Resolution: Crew replaced alarm with ship's spare; test sat.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 December 2008 Resolved
1530 - Radar - Notification was received from vessel of inoperable 10 cm radar. Certified repair is needed to return unit to normal operating specifications.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 December 2008
Resolved 2 March 2009
Resolution: Received technical report attesting to the repairs of the 10 cm radar. Defficiency was cleared.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 July 2008 Resolved
In accordance with 33 CFR §164.55, you are granted a deviation of the Navigation Safety Regulations for an inbound transit of U.S. waters into the Port of Los Angeles - Long Beach with an inoperable secondary radar system. You cannot depart until this equipment is repaired and fully functional.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2008
Resolution: Recieved tech report via fax attesting to repairs of radar.
Navigation › Piloting/Steering › Gyro Compass
Issued 22 April 2007 Resolved
The vessel was granted a deviation from the rules, allowing operation in the Sector New Orleans COTP zone with an inoperative gyro compass.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2007
Resolved 22 April 2007
Resolution: Received Tech report from Sperry Marine ServiceNet satisfying requirement.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 27 September 2005 Resolved
Vapor control system missing stud at connection flanges, Port and Starboard side, at maniford IAW 46 CFR 39.20-1 (e). Complete to the satisfaction of the flag state representative prior to next U.S. port after sailing foreign, unless at next U.S. port the VCS is to be used, then prior to next U.S. port.
Due 30 September 2005
Resolved 30 September 2005
Resolution: Class surveyor statement received that the alignment stud is installed in the flanges. This design is to the satisfaction of class.
Construction/Loadline › Structures › Door
Issued 27 September 2005 Resolved
Door from aft deck to steering room containing emergency fire pump was dead bolt locked from the interior. Make accessible from both sides IAW SOLAS Ch II-2 Reg 10.2.2.3.2.2.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 30 September 2005
Resolution: Butterfly system has been installed and inspected by ABS surveyor. Received fax from surveyor stating the installation was found satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.