MAURY USCG vessel records Sign in
← All vessels

NEWSEAS AMBER

NEWSEAS AMBER is a 2005 freight ship. The Coast Guard has recorded 18 inspections since 2005, most recently in October 2018, along with 6 deficiencies and 7 operational controls.

Records from 2005 to 2018. Most recent: operational control imposed, 17 October 2018.

Built
2005
Last inspected
17 October 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9317119 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
770074
Flag
PANAMA
—
Maury page id
psix-770074

Inspections, by type

…with no type recorded8
Years with a record 7 calendar years (2005–2018)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30046 - Convention (Subpart B), Gross Ton
18207 - Convention (Subpart B), Net Ton
52347 - Dead Weight, Metric Ton
60772 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

17 October 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6559382
17 October 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6563263
12 October 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6560345
28 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5889597
28 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5891530
18 May 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5880966
14 February 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5815020
5 March 2010 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex VI Survey · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3685972
7 February 2008 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3143646
31 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3139779
16 February 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2873070
6 October 2006 MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2795486
5 October 2006 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2790973
23 February 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2591067
21 February 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2588887
18 July 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2430805
16 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2428669
11 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2423412

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 October 2018 Resolved
07123- Operation of Fire Protection Systems- Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 liters and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed a blocking device in the remote quick closing valves on the LSMGO service tank. 01 valve was the supply to the ship service diesel generators. Ships crew stated the devices were placed in the valves to test quick closing valves on August 27, 2018 and were never removed. SOLAS 74 (04 CONS) II-2/4.2.2.3.4 30a
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 17 November 2018
Resolved 18 October 2018
Resolution: 18OCT18: Received class report from NKK stating all outstanding deficiencies have been rectified. The class report stated: quick closing valve bolt was removed and operationally tested satisfactory. The vessel was released from IMO Detention.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 October 2018 Resolved
07126- Oil Accumulation in Engine Room- Means shall be provided to control leaks of flammable liquids. PSCOs observed missing handles for manual fuel valves for #1, #3, #4 and #5 at the main engine. Crew immediately reattached handles and opend all fuel valves to each cylinder which resulted in excessive leaks on main engine fuel injectors on the #1, 3, 4, and 5 cylinders. SOLAS 74 (04 CONS) II-2/4.1.1 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 November 2018
Resolved 18 October 2018
Resolution: 18OCT18: Received class report from NKK stating all outstanding deficiencies have been rectified. The class report stated: O-rings were replaced, puntured fuel cylinder was repaired and all fuel leaks satisfactorily repaired. The vessel was released from
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 February 2007 Resolved
Non Slip surface missing from steering gear room deck. Install non slip surface to the satisfaction of the US Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 March 2007
Resolved 7 February 2008
Resolution: The PSCO noted that the vessel had non-slip surface in the steering gear room.
Operations/Management › Pollution › Control of Garbage
Issued 16 February 2007 Resolved
Plastic waste on board ship is not segregated. All waste containers including food waste contained plastic. According to garbage record book food waste is disposed of overboard. Conduct additional training of crew in accordance with garbage management plan. rectify to the satisfaction of the US Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 March 2007
Resolved 7 February 2008
Resolution: Plastic segregated as per Garbage Management Plan to the satisfaction of the attending Coast Guard Marine inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 October 2006 Resolved
During an expanded MARPOL Exam, the oily water separator (OWS) discharge side pipe, which connects to the through-hull valve was removed, where a dark oily substance was discovered. OWS appears unable to properly filter oily water. Vessel required to provide class report verifying proper operation of the OWS. MARPOL 73/78 Annex I, Regulation 8(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: OWS was fixed and operated to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 6 October 2006 Resolved
Provide class report verifying proper operation of the incinerator. SOLAS Regulation 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2006
Resolution: Incinerator was fixed and operated to the satisfaction of class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.