MAURY USCG vessel records
← All vessels

S'HAIL AL DUKHAN

S'HAIL AL DUKHAN is a 2005 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in March 2022, along with 6 deficiencies and 3 operational controls.

Records from 2016 to 2022. Most recent: inspection, 25 March 2022.

Built
2005
Last inspected
25 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9324239
772584
Flag
QATAR
Maury page id
psix-772584

Documentation record

Tonnage as PSIX records it38938 - Simplified, Gross Ton
24972 - Simplified, Net Ton
38938 - Convention (Subpart B), Gross Ton
24972 - Convention (Subpart B), Net Ton
74143 - Dead Weight, Ton
84294 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

10 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

25 March 2022 Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7418808
18 March 2022 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7407967
8 January 2020 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6885623
12 November 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6842577
31 October 2019 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6846510
18 September 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6264150
16 November 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6043839
15 November 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6041804
14 November 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6040375
8 April 2016 Ballast Water Examination · COE-Dockside · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5841282

Deficiency record · 6

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2022 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for service. It was reported that there was multiple propulsion ahead/astern start air irregularities. 74 SOLAS (Amend.) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2022
Resolved 5 April 2022
Resolution: 25MAR22: Received, reviewed and accepted Class Report from NKK attesting to the operational readiness of the #16 and 117 start air valves.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 16 November 2016 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immidiate use. The vessel's Emergency Fire Pump is not fully operational. Cite: 74SOLAS(2004 Cons.)Ch II/2 14.2.1.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2016
Resolution: Class report and dispensation received. Placed in docs
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 April 2016 Resolved
1730: The OWS/OCM is currently not cabaple of processing bildge water below 15 PPM. During testing crew attempted unsuccesfully for over an hour to prove operation of the system. Reviewed shipboard maintance showed the crew conducted 6 month overhaul and system cleaning in Nov15. However the bildge water effluent can not reach levels below 15 PPM due to sample concentration. Marpol I/14.7 17ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. OWS cleaned and flushed internally, pipe lines and valves as well. The oil content meter sensor was cleaned. Operation of OWS and oil content meter was checked Sat
Engineering › Steam System (main) › Piping
Issued 8 April 2016 Resolved
0999: PSCO observed steam condensate leaking from a small valve for fuel heating line at the incinerator deck. There was a plastic bottle under the leak to catch the water. Crew tightened and secured the leak. Solas (14) II-1/26.1 Code: 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2016
Resolution: Crew tightened and secured the leak.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 April 2016 Resolved
0950: Four lighting fixtures were temporarily hung above the ship service diesel generators with unapproved cable runs. Crew removed lighting fixtures. Solas(04) II-1/40.1.3 Code: 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 8 April 2016
Resolution: Crew removed lighting fixtures.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 April 2016 Resolved
0720: Fire fighting equipment in the midship deck store compartment was not ready for immediate use due to cluster and miscellaneous items throughout the compartment. Crew organized the space making the fire fighting equipment readily accessible. Solas (14) II-2/14.1.1.1 Code: 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2016
Resolution: Crew organized the space making the fire fighting equipment readily accessible.

Ownership record