← All vessels
UACC IBN AL ATHEER
UACC IBN AL ATHEER is a 2003 tank ship. The Coast Guard has recorded 14 inspections since 2005, most recently in March 2009, along with 7 deficiencies — 1 with no resolution recorded — and 2 operational controls.
Records from 2005 to 2009. Most recent: inspection, 17 March 2009.
- Built
- 2003
- Last inspected
- 17 March 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9254927 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HPBI
773283
Flag
PANAMA
—
Maury page id
psix-773283
Inspections, by type
…with no type recorded6
…past their stated due date1
Years with a record
4 calendar years (2005–2009)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28059 - Convention (Subpart B), Gross Ton
28059 - Regulatory (Subpart C or D), Gross Ton
11645 - Convention (Subpart B), Net Ton
11645 - Regulatory (Subpart C or D), Net Ton
44994 - Dead Weight, Ton
53781 - Displacement, Ton
28059 - Regulatory (Subpart C or D), Gross Ton
11645 - Convention (Subpart B), Net Ton
11645 - Regulatory (Subpart C or D), Net Ton
44994 - Dead Weight, Ton
53781 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
17 March 2009
ISPS I Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3433337
17 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3434515
17 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3435020
25 September 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3062369
23 September 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3063835
30 October 2006
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2810423
20 October 2006
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2804642
17 October 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2802136
30 August 2006
NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2764360
23 August 2006
COC-TVE Annual · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2757371
28 September 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2503869
27 September 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2502261
29 July 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2446909
28 July 2005
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2443504
Deficiency record · 7
Deck/Cargo › Cargo Stowage › General
Issued 30 August 2006
Resolved
Vessel carrying 154,591 NBBLS of Jet A-1 and is required to maintain an inert atmosphere of 8% or less oxygen. Oxygen levels above 8% were measured in 5 of 16 cargo tanks at the time of the exam. Provide Flag State survey attesting to cause and measures taken to prevent recurrence. 74 SOLAS (Con 2001) CH II-2 Reg 62.2.2.
Deck/Cargo › Cargo Stowage › General
Issued 30 August 2006
Resolved
Vessel did not demonstrate knowledge of essential shipboard procedures as evidenced by over 8% oxygen in several cargo tanks. I.E. Crew did not demonstrate knowledge of cargo tank atmosphere monitoring of conditions that would merit running the IGS. Provide Class Survey Report attesting to crew competency in this area prior to conducting cargo operations. 74 SOLAS XI-1/4 & STCW A/ V.12
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 23 August 2006
Resolved
The Ballast Water Plan has the incorrect amount of tanks listed. Plan states 16, tanks, vessel has 19 and one tank APT (P) is missing from the list. Ballast Water Handling log form is not approved by Company. Sediment removal and accountability has not been documented on the approved forms.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 August 2006
Resolved
The location of where the Central and Local Garbage containers are not indicated in the plan as required.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 23 August 2006
No resolution recorded
Two of the GMDSS radio batteries are not working. The crew is using the spare batteries until new ones can be provided, SOLAS 74am III/6.2.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 September 2005
Resolved
Fire damper at starboard lower pump room is rigged to open when remote wire rope is pulled from "A" deck, forward of house and starboard of cat walk. Have Class/Admin verify. SOLAS Ch II-2 Reg 5.2.1.1.
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 28 July 2005
Resolved
Marine Chemist was not aboard to issue the gas free certificate, pump room was not inspected.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.