MAURY USCG vessel records Sign in
← All vessels

UACC IBN AL ATHEER

UACC IBN AL ATHEER is a 2003 tank ship. The Coast Guard has recorded 14 inspections since 2005, most recently in March 2009, along with 7 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 2005 to 2009. Most recent: inspection, 17 March 2009.

Built
2003
Last inspected
17 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9254927 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
773283
Flag
PANAMA
—
Maury page id
psix-773283

Inspections, by type

…with no type recorded6
…past their stated due date1
Years with a record 4 calendar years (2005–2009)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28059 - Convention (Subpart B), Gross Ton
28059 - Regulatory (Subpart C or D), Gross Ton
11645 - Convention (Subpart B), Net Ton
11645 - Regulatory (Subpart C or D), Net Ton
44994 - Dead Weight, Ton
53781 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

17 March 2009 ISPS I Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3433337
17 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3434515
17 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3435020
25 September 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3062369
23 September 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3063835
30 October 2006 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2810423
20 October 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2804642
17 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2802136
30 August 2006 NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2764360
23 August 2006 COC-TVE Annual · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2757371
28 September 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2503869
27 September 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2502261
29 July 2005 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2446909
28 July 2005 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2443504

Deficiency record · 7

Deck/Cargo › Cargo Stowage › General
Issued 30 August 2006 Resolved
Vessel carrying 154,591 NBBLS of Jet A-1 and is required to maintain an inert atmosphere of 8% or less oxygen. Oxygen levels above 8% were measured in 5 of 16 cargo tanks at the time of the exam. Provide Flag State survey attesting to cause and measures taken to prevent recurrence. 74 SOLAS (Con 2001) CH II-2 Reg 62.2.2.
Due 30 September 2006
Resolved 31 August 2006
Resolution: Recieived faxed Class Survey Report.
Deck/Cargo › Cargo Stowage › General
Issued 30 August 2006 Resolved
Vessel did not demonstrate knowledge of essential shipboard procedures as evidenced by over 8% oxygen in several cargo tanks. I.E. Crew did not demonstrate knowledge of cargo tank atmosphere monitoring of conditions that would merit running the IGS. Provide Class Survey Report attesting to crew competency in this area prior to conducting cargo operations. 74 SOLAS XI-1/4 & STCW A/ V.12
Due 30 August 2006
Resolved 31 August 2006
Resolution: Received faxed Class Survey Report.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 23 August 2006 Resolved
The Ballast Water Plan has the incorrect amount of tanks listed. Plan states 16, tanks, vessel has 19 and one tank APT (P) is missing from the list. Ballast Water Handling log form is not approved by Company. Sediment removal and accountability has not been documented on the approved forms.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 November 2006
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 August 2006 Resolved
The location of where the Central and Local Garbage containers are not indicated in the plan as required.
Action required: 705 - Other - as specified
Due 23 August 2006
Resolved 23 August 2006
Resolution: Corrected by the [name withheld] under the Master''''s direction.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 23 August 2006 No resolution recorded
Two of the GMDSS radio batteries are not working. The crew is using the spare batteries until new ones can be provided, SOLAS 74am III/6.2.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2006 — due date passed with no resolution recorded
Resolution: The GMDSS radio batteries have been replaced. Vessel faxed copy of invoice to the Coast Guard.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 September 2005 Resolved
Fire damper at starboard lower pump room is rigged to open when remote wire rope is pulled from "A" deck, forward of house and starboard of cat walk. Have Class/Admin verify. SOLAS Ch II-2 Reg 5.2.1.1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2005
Resolved 28 September 2005
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 28 July 2005 Resolved
Marine Chemist was not aboard to issue the gas free certificate, pump room was not inspected.
Action required: 705 - Other - as specified
Due 29 August 2005
Resolved 27 September 2005
Resolution: CG Inspector inspected cargo pump room.

Ownership record