JOYCE MARIE is a 1960 towing vessel. The Coast Guard has recorded 14 inspections since 2000, most recently in July 2020, along with 31 deficiencies, 2 operational controls and 1 casualty investigation in 2018.

Records from 2000 to 2020. Most recent: inspection, 22 July 2020.

Built
1960
Last inspected
22 July 2020
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 22 July 2020
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2000–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA6995
Flag
UNITED STATES
Maury page id
psix-77453

Documentation record

Registered dimensions (L × B × D)46.2 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 36 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKREMER MOTOR COMPANY · GULFPORT, MS, UNITED STATES · built 1960
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGRAND RAPIDS, MI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TEDDY BEAR Towing Vessel · MISLE 794157 · 1 May 2006 · activity 2637830SCOTTY MCCOY Towing Vessel · MISLE 794160 · 1 May 2006 · activity 2637830TEDDY BEAR Towing Vessel · MISLE 794157 · 6 March 2006 · activity 2637663SCOTTY MCCOY Towing Vessel · MISLE 794160 · 6 March 2006 · activity 2637663

Inspection history · 14

22 July 2020 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7013335
1 August 2018 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6520617
21 May 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4597192
7 November 2012 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4480018
14 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3534026
8 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3528217
11 June 2009 MTSA Verification · Administration
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3501689
18 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3166843
1 May 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2637830
6 March 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2637663
6 October 2005 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2507530
15 June 2002 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1631841
14 March 2002 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1597456
25 May 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1050238

Deficiency record · 31

Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 October 2005 Resolved
Provide original Certificate of Documentation onboard vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Original Certificate of Documentation posted onboard
Operations/Management › Navigation Safety › Navigation Underway, Towing Vessels
Issued 6 October 2005 Resolved
Provide proof of required tests and inspections and log as required by 33 CFR 164.78(b) and 33 CFR 164.80
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2005
Resolution: Test and inspection checklist created and implemented.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 6 October 2005 Resolved
Provide properly Licensed Master of Towing Vessels with current Radar endorsement as required by 46 CFR 15.610 and 15.815(c).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2005
Resolution: Captians provided copies of Licenses with proper requirements
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 6 October 2005 Resolved
Provide mariner onboard with restricted radio operators Lic. as required by 46 CFR 164.72(a)(3)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2005 Resolved
Provide onboard current Coast Guard Light list as required by 33 CFR 164.72(b)(2)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Vessel brought Coast Guard Light list on board.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 6 October 2005 Resolved
Provide onboard vessel most current, up to date Local Notice to Mariners for operating area. Last ones onboard dated 2002. 33 CFR 164.72(b)(2)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: October 2005 Local Notice to Mariners onboard
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 October 2005 Resolved
Provide current addition of the Inland Navigation Rules, in accordance with 33 CFR 88.05.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Inland Navigation Rules onboard
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 October 2005 Resolved
Provide onboard vessel either a lighted Magnetic Compass, or Swing Meter in accordance with 33 CFR 164.72(a)(4). Vessel currently does not have either device.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Magnetic compass onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 October 2005 Resolved
Renew bottom stern tow light or replace missing amber globe and prove proper operation of towing lights per 33 USC 2024(i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2005
Resolution: Bottom amber globe replaced and proper operation witnessed by [name withheld].
Lifesaving › Lifebuoys › Serviceable
Issued 6 October 2005 Resolved
Provide Ring Bouy with retro reflective material in accordance with 46 CFR 25.25(d).
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2005
Resolution: New Ring Bouys brought onboard
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 October 2005 Resolved
Vessel had name [name withheld] displayed on Port and Starboard side and no hailing port on stern. Documented name of vessel is [name withheld]. Proper mark vessels name and hailing port IAW 46 CFR 67.123 and 46 CFR 67.121.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Vessel name properly displayed.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 6 October 2005 Resolved
Remove excess Fuel and Oil slops which pose a fire hazard from the Bilges of the vessel. Sounded bilges and found 14" of fuel/oil in bilges. In accordance with 33 CFR 155.330.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2005
Resolution: Bilge levels reduced to reasonable level as witnessed by CWO majors and [name withheld]
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 October 2005 Resolved
Vessel required to have 3 CG B-I extinguishers and 1 CG B-II in engineroom, Vessel was short one type B-I and the B-II for the engineroom. Ext. required per 46 CFR 25.30-20
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Sufficient amount of extinguishers onboard.
Personnel › Training › Fire Fighting Basic
Issued 6 October 2005 Resolved
Provide crew fire fighting training and knowledge of operation of installed fire fighting equipment in accordance with 46 CFR 27.209. No crew training had been preformed.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: Crew firefighting training was conducted and is logged in training log.
Communications › Alarms/Indicators › General Alarm
Issued 6 October 2005 Resolved
Vessel does not have installed a General Alarm with required red strobe and signage as required by 46 CFR 27.201.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: General Alarm with required red strobe and signage intalled and tested in E/R.
Communications › Alarms/Indicators › Fire Alarm
Issued 6 October 2005 Resolved
Vessel required to install a Fire detection system with either a registered Professsional Engineers Certification letter of Class Society (ABS) certification letter. Current installed system has been dismanteled and the detectors in the machinery space have been activated. Per 46 CFR 27.203
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Installed fire detection system has PE letter.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 October 2005 Resolved
Vessel required to install either a CG approved fixed fire system, or a B-V for the engineroom by 29 APR 2005. Install system in accordance with 46 CFR 27.303.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: Approved B-V onboard vessel. Receipts scanned into docs.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 6 October 2005 Resolved
Fuel tank vents missing flame screens. Install 30 by 30 mesh screens per 46 CFR 27.211(d)(1)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2005
Resolution: Flame Screens fitted on fuel tank vents
Fire Fighting › Fire Pumps › Arrangement
Issued 6 October 2005 Resolved
Vessel lacks either a fixed or portable fire pump. Vessel required to either install a fixed, or portable fire pump meeting the requirments of 46 CFR 27.301 by 29 APR 2005.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Portable fire pump onboard and tested.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 6 October 2005 Resolved
Governor linkage on port engine found jury rigged with vise grips and wire holding linkage on the governor. Additionally, rotating machinery (alternators) lack guards. Properly connect Morse cable Governor linkages and provide guards on machinery to mitigate unsafe conditions per 33 CFR 160.113
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Governor linkage was properly installed.
Electrical › Lighting (service) › Switch
Issued 6 October 2005 Resolved
Engineroom light switch found hanging out of box with switch cover missing. Reinstall switch in box and provide proper cover to mitigate unsafe condition per 33 CFR 160.113.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Light switch in E/R properly installed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 6 October 2005 Resolved
Electrical distribution panel found without proper cover in engineroom. Provide proper cover for panel to mitigate unsafe condition per 33 CFR 160.113.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Elec distribution panel had proper cover.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 October 2005 Resolved
Lighting fixtures throughout the vessel found missing guards and globes, and were hanging by the conductors unsupported. Provide guards and globes and properly secure fixures to the overheads to mitigate unsafe condition per 33 CFR 160.113.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: All light fixtures had proper covers.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 October 2005 Resolved
Company could not provide proof of chemical testing program for marine employees. Provide proof of program per 46 CFR 16.201
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: Company had an approved proof of chemical testing program for marine employees through Maritime Consortium Inc.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 October 2005 Resolved
No records could be produced at work site for Chemical testing program. Produce company's chemical testing program records in accordance with 46 CFR 16.260
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: All records were onsite for Chemical testing program and are scanned into doc''s.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 October 2005 Resolved
Vessel operators could not produce proof of negative lab test results signed by MRO for mariners operating vessel at time of attendance. Provide proof mariners have been pre-employment tested with negative lab results signed by MRO as required by 46 CFR 16.10(a)(b).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: Pre-employment tests with negative lab results were present for all employees.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 6 October 2005 Resolved
No Proof of random chemical testing program with valid 50% of covered crew being tested annually could be produced. Provide proof of random program enrollment of all covered employees, with test records for showing 50% annual testing per 46 CFR 16.230(e)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: Crew is enrolled in random chemical testing program with valid 50% of covered crew being tested annually.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 October 2005 Resolved
Complete Chemical testing program is out of compliance, no eap training or display, random or pre-employment testing, records. Prior to operations company program needs audited for compliance with 46 CFR 16.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2009
Resolution: DAPI program is compliant with current regulations.
Documentation › Markings/Placards › Official Number (US)
Issued 6 October 2005 Resolved
Official Number not clearly visible on interior structure of hull as required by 46CFR67.121
Action required: 705 - Other - as specified
Resolved 11 October 2005
Resolution: Official Number welded and painted to interior structure of hull
Fire Fighting › Miscellaneous Items
Issued 25 March 2002 Resolved
NO GENERAL ALARM PLACARD IN MACHINE SPACE 46 CFR 27.205
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2002
Resolution: GENERAL ALARM PLACARD INSTALLED
Fire Fighting › Remote Fuel Shutoff
Issued 14 March 2002 Resolved
NO REMOTE FUEL OIL SHUT OFF INSTALLED 46 CFR 27.230
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2002
Resolution: REMOTE FUEL SHUT OFF INSTALLED

Casualty record · 1

1 August 2018Routine · role: Acknowledged Pollution Source · activity 6520617
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record