Records from 1989 to 2000. Most recent: inspection, 30 August 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
30 August 2000
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 822268
10 August 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 810917
18 August 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1472524
21 May 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 792319
18 August 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 776840
8 August 1996
Re-Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1270779
14 June 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1134266
11 December 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 878575
24 August 1995
Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1188150
9 June 1995
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 880466
31 August 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 869711
24 August 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1439544
29 June 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1173879
17 June 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1353620
20 October 1993
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1153739
17 September 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1407195
25 August 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 952969
29 May 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1263965
14 August 1990
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1223430
5 July 1990
Hull Examination · Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1211842
1 August 1989
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 890745
24 April 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1209998
Fire Fighting
Issued 24 August 1995
Resolved
SERVICE VESSEL'S FIXED HALON FIGHTING FIRE SYSTEM.
Condition: Unknown
Due 24 December 1995
Resolved 19 September 1995
Accommodation/Occupational Safety
Issued 24 August 1995
Resolved
INSTALL A SOLENOID VALVE AT THE CYLINDER OPERABLE FROM THE LPG STOVE.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Accommodation/Occupational Safety
Issued 24 August 1995
Resolved
POST A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 24 September 1995
Resolved 19 September 1995
Electrical
Issued 24 August 1994
Resolved
PROVIDE BATTERY COVERS FOR THE TWO BATTERIES IN THE ENGINE ROOM.
Condition: Unknown
Due 1 September 1994
Resolved 31 August 1994
Engineering
Issued 24 August 1994
Resolved
PROVIDE DRIP PAN FOR THE FUEL FILTER IN THE ENGINE ROOM.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Lifesaving
Issued 17 September 1993
Resolved
CONDUCT UNDERWAY DRILLS IN PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Electrical
Issued 14 August 1990
Resolved
REPAIR LOOSE SWITCH PLATE FOR ELECTRIC BILGE PUMP.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Electrical
Issued 14 August 1990
Resolved
INSTALL CORROSION-PROOF BOX AROUND ELECTRONICS BATTERY.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Fire Fighting
Issued 14 August 1990
Resolved
REPAIR LOOSE INDICATOR LIGHT FOR FIXED HALON SYSTEM.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990