← All vessels
TILDA KOSAN
TILDA KOSAN is a 1999 tank ship. The Coast Guard has recorded 26 inspections since 2000, most recently in September 2019, along with 15 deficiencies and 6 operational controls.
Records from 2000 to 2019. Most recent: inspection, 21 September 2019.
- Built
- 1999
- Last inspected
- 21 September 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9174359 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZIQT4
775
Flag
ISLE OF MAN
—
Maury page id
psix-775
Inspections, by type
…with no type recorded7
Years with a record
15 calendar years (2000–2019)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1754 - Convention (Subpart B), Net Ton
4693 - Convention (Subpart B), Gross Ton
5992 - Dead Weight, Ton
9051 - Displacement, Ton
4693 - Convention (Subpart B), Gross Ton
5992 - Dead Weight, Ton
9051 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
21 September 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6821108
19 September 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6815885
14 December 2018
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6595017
6 January 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6333096
5 October 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6281819
4 September 2017
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6242805
10 January 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5794633
28 July 2015
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5190161
17 August 2011
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4118688
1 January 2011
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3918868
6 March 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3429046
24 September 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3328441
11 May 2007
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2927687
2 May 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2920617
4 May 2006
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2640715
5 April 2005
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2326990
4 April 2005
COC-GAS Renew
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2326152
4 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2327815
22 September 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1911004
15 September 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1928385
29 July 2002
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1651532
29 July 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1654314
3 January 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1475701
5 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293510
24 January 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 274270
24 January 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1045649
Deficiency record · 15
Documentation › Certificates/Documents › Certificate of Fitness (GC Code)
Issued 4 September 2017
Resolved
Code: 0130, documentation/certificates. Pressure relief valves should be set and sealed by a competent authority acceptable to the administration. Set and seal certificate missing recognized organization (class) approval. 74SOLAS(14)VII/12.1, IC+GC(93) 8.2.5
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 28 July 2015
Resolved
SOLAS 74 (2009 Cons Ed.) I/II(a)
Multiple holdback hooks and improper wire installations found on self closing a class doors, and quick closing valves.
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2015
Resolved
SOLAS 74 (2004 CONS ED) II-1/45.4.4; SOLAS 74 (2004 CONS ED.) II-1/45.5.5
WIRING ABOVE CENTRAL COOLERS NOT WORKING AS INTENDED AND UNPROTECTED. WIRING DRAPED OVER CENTRAL COOLERS AND RELATED PIPING.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 28 July 2015
Resolved
SOLAS 74 (2004 CONS ED) II-1/3-1
GENERAL SERVICE PUMP LEAKING SIGNIFICANTLY FROM PACKING GLAND.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 July 2015
Resolved
SOLAS 74 (2009 CONS ED) I/II(A)
ENGINE ROOM FOUND TO BE SIGNIFICANTLY LACKING IN CLEANLINESS WITH RAGS AND OIL THROUGHOUT SPACE.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 17 August 2011
Resolved
On ships carrying flammable or toxic products or both a waterspray system for protection should be installed and working properly. The deluge system had clogged nozzles preventing the protection on the cargo manifolds and house structure.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 17 August 2011
Resolved
Vessel had incinerator for use of disposing sludge IAW the IOPP certificate. The vessels incinerator could not be started during the initial inspection of the engine room.
Electrical › Electric Generation Source (service) › Panelboard
Issued 17 August 2011
Resolved
Vessel's Aux EG-2 would not start in automatic mode, only in manual. Vessel had ordered a tech to arrive and repair prior to the vessel's departure.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 1 January 2011
Resolved
2 of 16 lifeboat rations are not in air tight packaging. All lifeboat rations shall be kept in airtight packaging and be stowed in a watertight container. -LSA Code Ch. IV.4.1.5.1.18
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 4 May 2006
Resolved
The No. 1 liquid line valve on the stbd cargo manifold does not function.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 4 May 2006
Resolved
The incinerator refractory in the fire box has failed.
Lifesaving › Rocket Parachute Flares
Issued 22 September 2003
Resolved
Parachute flare for life boat are expired. Attain new Parachute flares onboard prior to departure.
Electrical › Lighting (emergency)
Issued 29 July 2002
Resolved
Repair Emergency light above 6 man life raft on BOW. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Lighting (service)
Issued 29 July 2002
Resolved
Repair explosion proof light above stbd compressor motor. LEGACY COMPONENT DESC: Lighting Fixture
Construction/Loadline
Issued 5 September 2001
Resolved
Provide onboard, MARPOL Standard Discharge Connection IAW MARPOL Annex I, REG 19 to the satisfaction of the certificate issuing authority (BV)._x001C_ _x001C_ _x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.