MAURY USCG vessel records Sign in
← All vessels

TILDA KOSAN

TILDA KOSAN is a 1999 tank ship. The Coast Guard has recorded 26 inspections since 2000, most recently in September 2019, along with 15 deficiencies and 6 operational controls.

Records from 2000 to 2019. Most recent: inspection, 21 September 2019.

Built
1999
Last inspected
21 September 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9174359 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ISLE OF MAN
—
Maury page id
psix-775

Inspections, by type

…with no type recorded7
Years with a record 15 calendar years (2000–2019)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1754 - Convention (Subpart B), Net Ton
4693 - Convention (Subpart B), Gross Ton
5992 - Dead Weight, Ton
9051 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

21 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6821108
19 September 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6815885
14 December 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6595017
6 January 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6333096
5 October 2017 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6281819
4 September 2017 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6242805
10 January 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5794633
28 July 2015 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5190161
17 August 2011 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4118688
1 January 2011 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3918868
6 March 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3429046
24 September 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3328441
11 May 2007 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2927687
2 May 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2920617
4 May 2006 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2640715
5 April 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2326990
4 April 2005 COC-GAS Renew
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2326152
4 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2327815
22 September 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1911004
15 September 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1928385
29 July 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1651532
29 July 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1654314
3 January 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1475701
5 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293510
24 January 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 274270
24 January 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1045649

Deficiency record · 15

Documentation › Certificates/Documents › Certificate of Fitness (GC Code)
Issued 4 September 2017 Resolved
Code: 0130, documentation/certificates. Pressure relief valves should be set and sealed by a competent authority acceptable to the administration. Set and seal certificate missing recognized organization (class) approval. 74SOLAS(14)VII/12.1, IC+GC(93) 8.2.5
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 5 October 2017
Resolution: Received documentation for 2013 set and seal cert stamped by BV, and explanation that 2016 cert was for a field test only that did not involve adjustment of the valves or breaking of the 2013 sealing wires.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 28 July 2015 Resolved
SOLAS 74 (2009 Cons Ed.) I/II(a) Multiple holdback hooks and improper wire installations found on self closing a class doors, and quick closing valves.
Action required: 705 - Other - as specified
Due 28 July 2015
Resolved 28 July 2015
Resolution: Steel wiring and hold back hooks removed.
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2015 Resolved
SOLAS 74 (2004 CONS ED) II-1/45.4.4; SOLAS 74 (2004 CONS ED.) II-1/45.5.5 WIRING ABOVE CENTRAL COOLERS NOT WORKING AS INTENDED AND UNPROTECTED. WIRING DRAPED OVER CENTRAL COOLERS AND RELATED PIPING.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 January 2016
Resolution: Received documentation from vessel attesting to proper repair and covering of exposed wiring.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 28 July 2015 Resolved
SOLAS 74 (2004 CONS ED) II-1/3-1 GENERAL SERVICE PUMP LEAKING SIGNIFICANTLY FROM PACKING GLAND.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 January 2016
Resolution: Received documentation attesting to overhaul/repair of pump to eliminate leakage.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 July 2015 Resolved
SOLAS 74 (2009 CONS ED) I/II(A) ENGINE ROOM FOUND TO BE SIGNIFICANTLY LACKING IN CLEANLINESS WITH RAGS AND OIL THROUGHOUT SPACE.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 January 2016
Resolution: Master submitted photographs and additional documentation confirming removal of oily rags and improved overall cleanliness.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 17 August 2011 Resolved
On ships carrying flammable or toxic products or both a waterspray system for protection should be installed and working properly. The deluge system had clogged nozzles preventing the protection on the cargo manifolds and house structure.
Due 23 August 2011
Resolved 23 August 2011
Resolution: Vessels crew cleared the nozzles and ran system to force the rust out of the pipes. After testing the system again, all areas required to be protected, were covered by the system.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 17 August 2011 Resolved
Vessel had incinerator for use of disposing sludge IAW the IOPP certificate. The vessels incinerator could not be started during the initial inspection of the engine room.
Due 23 August 2011
Resolved 23 August 2011
Resolution: The crew worked on the incinerator during the inspection and fixed it to where it was operating properly and ready for use.
Electrical › Electric Generation Source (service) › Panelboard
Issued 17 August 2011 Resolved
Vessel's Aux EG-2 would not start in automatic mode, only in manual. Vessel had ordered a tech to arrive and repair prior to the vessel's departure.
Due 23 August 2011
Resolved 24 August 2011
Resolution: Technician visited vessel and corrected the problem. SEE TECH REPORT ATTACHED IN DOCUMENTS.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 1 January 2011 Resolved
2 of 16 lifeboat rations are not in air tight packaging. All lifeboat rations shall be kept in airtight packaging and be stowed in a watertight container. -LSA Code Ch. IV.4.1.5.1.18
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2011
Resolution: Received receipt for purchase of 04 lifeboat rations and statement from Master attesting to the delivery of rations on board.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 4 May 2006 Resolved
The No. 1 liquid line valve on the stbd cargo manifold does not function.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 5 May 2006
Resolution: Received class report. Condition of class was issued to be rectified by 11 May 2006. Deficiency cleared.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 4 May 2006 Resolved
The incinerator refractory in the fire box has failed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 5 May 2006
Resolution: Received class report. A condition of class was issued to repair the incinerator by 03 June 2006 and discharge all sludges ashore until repaired.
Lifesaving › Rocket Parachute Flares
Issued 22 September 2003 Resolved
Parachute flare for life boat are expired. Attain new Parachute flares onboard prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2003
Resolution: RECIEVED FAX WITH RECEIPT FOR ALL NEEDED DISTRESS SIGNALS
Electrical › Lighting (emergency)
Issued 29 July 2002 Resolved
Repair Emergency light above 6 man life raft on BOW. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2002
Resolved 22 September 2003
Electrical › Lighting (service)
Issued 29 July 2002 Resolved
Repair explosion proof light above stbd compressor motor. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 August 2002
Resolved 22 September 2003
Construction/Loadline
Issued 5 September 2001 Resolved
Provide onboard, MARPOL Standard Discharge Connection IAW MARPOL Annex I, REG 19 to the satisfaction of the certificate issuing authority (BV)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 October 2001
Resolved 3 January 2002
Resolution: Vessel provided MARPOL Standard Discharge Connection IAW MARPOL Annex I, REG 19.

Ownership record