MAURY USCG vessel records
← All vessels

ISLAND DISCOVERY

ISLAND DISCOVERY is a 2005 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 47 deficiencies, 1 operational control and 5 casualty investigations between 2006 and 2011.

Records from 2006 to 2026. Most recent: inspection, 3 June 2026.

Built
2005
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI9992
775281
Flag
UNITED STATES
Maury page id
psix-775281

Documentation record

Registered dimensions (L × B × D)64.1 ft × 19.5 ft × 7.2 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND BOATS INC. · JEANERETTE, LA, UNITED STATES · built 2005
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

3 June 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8390087
1 September 2025 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8198401
18 June 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8167463
21 November 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8035405
18 June 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7975694
24 May 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7971528
6 December 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7834733
20 July 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7511229
14 July 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7507268
24 November 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7356924
29 September 2020 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7067717
20 July 2020 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7010948
10 January 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6886924
28 November 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6586480
19 July 2018 Internal Structural Exam · Spot Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6484421
19 July 2018 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6488342
10 January 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6335825
11 January 2017 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069068
27 September 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6010338

Deficiency record · 47

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 September 2025 Resolved
Certificate of Documentation not current
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 September 2025
Resolution: Crew produced receipt for new COD
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 September 2025 Resolved
FWD Bulkhead of engeine room into Aft section of black tank void was missing insulation in a bulkhead penetration creating an opening in the boundary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 9 September 2025
Resolution: Penetration satisfactorily Insulated
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 September 2025 Resolved
Epirb battery beyond expiration date. Epirb still functional.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 26 September 2025
Resolution: EPIRB Replaced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 September 2025 Resolved
Backup batteries for fire panel were depleted and would not charge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 9 September 2025
Resolution: Fire panel batteries replaced with new batteries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 September 2025 Resolved
02 hatches observed non operational: Port Steering space and STBD anchor storage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 9 September 2025
Resolution: 01 Hatch satisfactorily repaired and 01 Hatch replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2024 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI noted the following: 1. Portside steering ram mount cracked at base, 2. Bushing missing, 3. Hydraulic fittings corroded and hydraulic fuel leaking on both port and starboard side steering. Repair to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2024
Resolved 26 November 2024
Resolution: Replaced steering ram mount and componment. Steering system operated as designed.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 November 2024 Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. Fire control plan missing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2024
Resolved 26 November 2024
Resolution: Poseted fire control plan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Starboard battery not maintaining voltage. Repair to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2024
Resolved 26 November 2024
Resolution: Replaced battery.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 November 2024 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. Starboard fuel tank vent flame screen wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Flamescreen replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 November 2024 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Log missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Added log to regular maintenance plan.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Location and identification of pfds was missing on upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Properly labeled storage areas.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Display placard for each type of pfd the vessel has in service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Displayed correct placards for each type of PFD.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 November 2024 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q. Vessel missing full complement of flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Purchased new flares to meet requirements.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 November 2024 Resolved
Decks and bulkheads machinery spaces must be categorized as A-60 fire control boundary. MI noted the following: 1. Insulation was missing from the overhead of the engine compartment, 2. Cable penetration on aft bulkhead did not contain appropriate insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Properly installed insulation in overhead and cable penetration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Readjust valve to that it fully opens and closes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Readjusted valves for proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2024 Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps that have no sharp edges and are insulated to protect against corrosion. Starboard engine fuel fittings corroded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Replaced fittings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 November 2024 Resolved
A hatch cover must: Have securing devices. The securing handle on the starboard lazarette and tank room did not properly engage to make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: Repaired handles to make hatches watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2024 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Replace cover on electrical outlet behind bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 26 November 2024
Resolution: replaced electrical outlet cover.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 July 2022 Resolved
subchapter F of this chapter, except that § 119.730 of this part replaces § 56.60-20 in subchapter F of this chapter. There are several holes and excessive corrosion in fire main piping, renew all deteriorated piping. 46 CFR 119.710(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2022 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Diesel drain line is dry rotted and valve is missing handle without means to shut off. Renew diesel drain hose and valve. 46 CFR 199.455(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2022
Resolution: Vessel replaced hoses and valves.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 29 July 2022 Resolved
Company and vessel personnel responsible for security duties must maintain a TWIC. No crew members could provide proof of valid TWIC, provide proof of TWIC. 33 CFR 104.220
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2022
Resolution: Proof of twic was provided for vessel designated crew.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 July 2022 Resolved
A vessel must be provided with a piping system that meets § 56.50-50 in subchapter F of this chapter Bilge piping is excessively corroded and bilge piping strainers missing in aft most voids. Renew corroded piping and install missing strainers. 46 CFR 119.510
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 July 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Interior pitting below waterline and bottom plates throughout vessel; clean for further inspection and provide repair plan. 46 CFR 116.100(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2022
Resolution: Due to drydock situation and low risk of vessel route. MI authorized a temporary repair. Vessel will need to cut and renew section on next drydock
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 July 2022 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Pull handle for stbd fuel shutoff broken, renew 46 CFR 119.455(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 1 August 2022
Resolution: New valve handle was intalled. Both tanks were tested. Test sat
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 July 2022 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150 Lifeline and grab lines on life buoys heavily deteriorated, renew. 46 CFR 117.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 1 August 2022
Resolution: New life ringbouy was installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 July 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. Flame screen on goosenecks need to be cleaned and reattached. 46 CFR 119.450(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 1 August 2022
Resolution: Flame screens were cleaned and re-attached properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2022 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Battery cover missing in port engine space; replace with new 46 CFR 120.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 1 August 2022
Resolution: Battery Covers were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 July 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Lifejackets on board are discolored and showing aging signs. Replace 25% of faded lifejackets per quarter
Action required: 705 - Other - as specified
Resolved 1 August 2022
Resolution: Vessel discarded all faded lifejackets and aquired new ones.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following… inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Disconnected electrical plug aft of port engine. 46 CFR 115.804(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2022
Resolved 1 August 2022
Resolution: Transmission oil sensor was replaced due to broken clip. Test sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 November 2021 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet.Pressure at both fire hose stations is reduced due to potential air leak(s)or sea chest restriction. Provide proper operation of pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2021
Resolution: Vessel operator provided proper operation of fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 November 2021 Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Starboard lazarette bilge suction pick-up did not develop suction. Provide proper operation of all bilge suction pick-ups throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2021
Resolution: Vessel operator provided proper operation of bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2020 Resolved
The number and identification of the items stowed inside must be marked on each container for life jackets. Label 2 benches in the cabin used to stow lifejackets. 46 CFR 122.604
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 14 October 2020
Resolution: Benches properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2020 Resolved
An adult lifejacket must be provided for each person carried onboard a vessel. Replace 8 lifejackets. 46 CFR 117.71
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 30 September 2020
Resolution: replaced before inspection complete.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 September 2020 Resolved
Vessels on limited coastwise routes must carry 6 hand red flares and 6 hand orange smoke. Vessel has 4 flares and 3 smoke onboard. 46 CFR 117.68
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 30 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2020 Resolved
Renew or replace retro-reflective tape on 4 identified lifejackets and replace 1 worn lifejacket identified.
Action required: 10 - Deficiency Rectified
Resolved 10 January 2020
Resolution: all identified lifejackets replaced with new ones.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 January 2020 Resolved
Replace 15x30 section of missing insulation in port side engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2020
Resolution: Received picture evidence of repair of insulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 November 2018 Resolved
Fire alarm control panel in wheelhouse inoperable. Unable to energize for testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Attended vessel to confirm repair of alarm.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 November 2018 Resolved
Expired Battery. Vessel restricted to less than 3 miles while conducting passenger operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 21 February 2019
Navigation › Piloting/Steering › Marine Charts
Issued 11 January 2017 Resolved
Provide up-to-date charts for area of operation. 46 CFR 121.420
Due 18 January 2017
Resolved 12 January 2017
Resolution: Vessel provided up-to-date charts.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 January 2017 Resolved
Provide up to date tide tables and current publications. 46 CFR 121.420
Due 18 January 2017
Resolved 12 January 2017
Resolution: Provided onboard.
Engineering › Bilge Water Management System › Pump
Issued 11 January 2017 Resolved
Starboard bilge pump found inoperable. Renew as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2017
Resolution: Bilge pump found operational.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 January 2017 Resolved
51 Lifejackets found in an unserviceable condition or missing. Reduced PAX count to 153.
Due 18 January 2017
Resolved 12 January 2017
Resolution: 51 New lifejackets were provided onboard. Increased PAX count to reflect COI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 January 2017 Resolved
Post COI in conspicuous location. 46 CFR 115.302
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 9 February 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 September 2016 Resolved
Starboard Generator exhaust tubing was found with excessive pitting. 46 CFR 115.802
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2016
Resolution: Replaced tube with 5086 1/4'' aluminum tube (as original).
Engineering › Bilge Water Management System › Piping
Issued 27 September 2016 Resolved
Bilge piping in fresh water storage tank compartment found wasted/holed. Renew as original. 46 CFR 119.510
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2016
Resolution: Renewed as original.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 September 2016 Resolved
Forward railing sanctions found with welds cracked all the way through. Renew welds as original. 46 CFR 116.900
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2016
Resolution: Stanchions re-welded as original.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 27 September 2016 Resolved
Starboard prop found with pitting and multiple cracks. Renew as original. 46 CFR 115.802
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2016
Resolution: Owner renewed prop as original.

Casualty record · 5

9 September 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2775359
22 March 2010Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3701781
27 July 2010Routine · role: Involved in a Marine Casualty · activity 3809163
31 January 2011Routine · role: Involved in a Marine Casualty · activity 3947811
2 May 2011Routine · role: Involved in a Marine Casualty · activity 4001361
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.