Records from 2006 to 2025. Most recent: inspection, 17 July 2025.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.3 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INT'L BOAT WORKS INC · FORT PIERCE, FL, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPERRYSBURG, OH
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
17 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8188192
30 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8024647
8 May 2023
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7684490
23 May 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7457671
22 April 2021
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7180480
6 April 2021
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7169668
5 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7020212
28 April 2020
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6945150
16 May 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6685564
26 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6390142
3 May 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6138619
13 April 2016
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5852529
12 August 2015
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5211734
7 May 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4847264
28 April 2009
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3456421
28 April 2008
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3193956
11 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2906067
21 April 2006
COI Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2630613
14 April 2006
Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2624743
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 May 2023
Resolved
A PENETRATION IN A WATERTIGHT BULKHEAD MUST BE AS HIGH AND AS FAR INBOARD IN THE BULKHEAD AS PRACTIABLE AND MADE WATERTIGHT. THE FORWARD WATERTIGHT BULK HEAD HAD PENETRATIONS INSIDE THE PORT AND STARBOARD HATCHES THAT WAS NOT MADE WATERTIGHT.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 15 June 2023
Resolution: Vessel submitted evidence of penetrations made watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 May 2022
Resolved
EACH VESSEL CERTIFICATED TO OPERATE ON THE GREAT LKES IN COLD WATER MUST BE PROVIDED WITH SURVIVAL CRAFT EQUALING 100% OF THE PERSONS ON BOARD. THE VESSEL IS CERTIFICATED FOR THE CARRIAGE OF 15 PASSENGERS, PLUS CREW, WHILE HAVING A LIFE FLOAT FOR 12 PERSONS ON BOARD. VESSEL RESTRICTED TO 12 PERSONS ON BOARD.
46CFR180.200(c)
Action required: 705 - Other - as specified
Resolved 31 May 2022
Resolution: Vessel's COI reduced to 12-pax.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 May 2022
Resolved
EACH VESSEL SHALL CARRY ON BOARD CURRENT NAUTICAL PUBLICATIONS, AS REQUIRED BY THIS PART. THE PUBLICATIONS ON BOARD THE VESSEL WERE NOT CURRENT.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 15 June 2022
Resolution: Received photographs of new publications onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2022
Resolved
EACH VESSEL SHALL CARRY A FIRST AID KIT MEETING THE REQUIREMENTS OF 160.041 ON BOARD. THE VESSELS FIRST AID KIT DID NOT HAVE ALL OF THE REQUIRED ITEMS IN 160.041.
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2022
Resolution: Received photograph of a new, additional first aid kit on the vessel, to be paired with existing kits.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 April 2021
Resolved
Vessel Replaced EPIRB with a Category II EPIRB. Vessel is required to be equipped with a Category I EPIRB. Vessel is required to replace EPIRB and operate inside of 3 Nautical Miles until the EPIRB is the correct type and mounted in a float free arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 22 April 2021
Resolution: Vessel owner provided evidence of proper EPIRB bracket being purchased.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 April 2020
Resolved
EPIRB Battery expired on 02/2020. Replace battery in EPRIB or purchase new unit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2020
Resolved 6 May 2020
Resolution: New EPIRB Purchased Serial number 2DCC9 FCA86 FFBFF and registration completed with NOAA.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 May 2019
Resolved
Vessel USCG Certificate of Documentation (COD) has expired and owner has not renewed the COD after its expiration in FEB 2019. Vessel can not carry passengers until the COD is renewed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2019
Resolved 16 May 2019
Resolution: Vessel Sent reciept of renewal to MI. Vessel can now operate with passengers on board.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 May 2019
Resolved
Floating light on life float and ring life buoy have expired batteries. lights were functioning. Replace batteries within 7 days.
Action required: 705 - Other - as specified
Due 23 May 2019
Resolved 17 May 2019
Resolution: Replaced
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2017
Resolved
FCC ship station liscense, Great Lakes Radio agreement inspectoin, and radio operators permits are expired or non existent. Renew ship station liscense, conduct great lakes radio agreement inspection and obtain radio operators permit as required by 47CFR80.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 5 June 2017
Resolution: All FCC paperwork is up to date and available.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2017
Resolved
Provide an emergency communication placard, specific to the vessel, as required by 46CFR184.506
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 5 June 2017
Resolution: Provided emergency comms placard as required.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2017
Resolved
Provide a current/corrected navigation chart as required by 46CFR184.420 for your area of operations.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 5 June 2017
Resolution: Current chart provided
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2016
Resolved
Ring-buoy grab-line was found in deteriorated condition. Replace ring-buoy in accordance with all applicable fit-out, stowage, and marking requirements found in (46 CFR 180.70 and 185.604).
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 22 April 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 April 2016
Resolved
Lifefloat waterlight battery was found expired. Replace battery in accordance with (46 CFR 180.175).
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 22 April 2016
Lifesaving › Lifefloat › Painter
Issued 13 April 2016
Resolved
Lifefloat painter was found in deteriorated condition. Replace painter in accordance with (46 CFR 180.175).
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 22 April 2016
Communications › Radio Communications › EPIRB
Issued 7 May 2014
Resolved
Install current hydrostatic release for EPIRB. Until installation, stow EPIRB at operator's station for ready access to manually deploy. 46CFR 180.64
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 2 June 2014
Resolution: O/O received and installed current hydrostatic release and properly mounted EPIRB in manufacturer''s case for automatic deployment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 May 2014
Resolved
Prove proper annual maintenance/inspection of fixed fire fighting system and portable extinguishers. 46CFR 177.405, 46CFR 176.810.
Due 22 May 2014
Resolved 21 May 2014
Resolution: Received fax transmittal of servicing company''''s invoice.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 April 2006
Resolved
Ensure master [name withheld] has a Radio Operators Permit.
Condition: Placed in Improper Service
Due 12 July 2006
Resolved 19 June 2006
Resolution: Inspected [name withheld] permit, all sat.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 21 April 2006
Resolved
Double hose clamp all raw water lines.
Condition: Placed in Improper Service
Due 12 July 2006
Resolved 19 June 2006
Resolution: Inspected double hose clamp''s, all sat.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 21 April 2006
Resolved
Replace the heat exchanger raw water hose, hose was not reinforced and collapsed.
Condition: Improper Installation
Due 12 July 2006
Resolved 26 June 2006
Resolution: Vessels owner installed new reinforced hose of the proper marine grade, all sat.