Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Oceania District (CGD-O) · Other hulls named HOE AMA'U
HOE AMA'U is a 2005 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2005, most recently in November 2025, along with 47 deficiencies and 1 operational control.
Records from 2005 to 2025. Most recent: inspection, 6 November 2025.
- Built
- 2005
- Last inspected
- 6 November 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 47 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1177141
WDI6203
778540
Flag
UNITED STATES
367075310
Maury page id
psix-778540
Inspections, by type
…with no type recorded1
Years with a record
17 calendar years (2005–2025)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS, INC · TARPON SPRINGS, FL, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI6203MMSI 367075310 · active · compulsorily equipped · granted 10 January 2026, expires 19 February 2036
WDC7692MMSI 367075310 · expired · compulsorily equipped · granted 5 November 2005, cancelled 9 January 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
6 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8260628
3 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7990722
7 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7992140
7 November 2023
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7807536
1 December 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7596188
28 October 2022
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7553912
7 December 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7364674
22 December 2020
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7114906
7 December 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7112962
17 December 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6875828
12 December 2018
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577843
5 December 2017
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6319827
26 January 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6077822
5 December 2016
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6057917
19 February 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5807647
15 August 2014
Administrative Inspection · DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4955831
24 February 2011
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3940875
23 February 2010
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3684968
23 February 2010
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3716711
12 May 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3473233
20 February 2009
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3421305
3 February 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3411889
22 January 2009
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3398477
20 March 2008
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3169196
12 February 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3145954
11 January 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2845143
17 November 2005
Initial Certification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2536467
28 June 2005
Construction Oversight · Plan Review "T" Boat · Simplified Stability Test · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2454398
Deficiency record · 47
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 November 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Starboard bilge alarm is not operational. Repair the the starboard bilge alarm to the satisfactions of the attending marine inspectors.
46 CFR 182.530(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2025
Resolved
A submersible electric bilge pump must be permanently mounted. The submersible electric bilge pump is not permanently mounted. Mount the electric bilge pump to the satisfactions of the attending marine inspectors.
46 CFR 182.520(e)(3)
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 November 2024
Resolved
46 CFR 182.530: A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces.
The indicating light for the port side high water level alarm was inoperable.
Repair or replace the light, to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 18 March 2024
Resolved
Except as provided in paragraph (c) of this section, each vessel must, in each condition of loading and operation, comply with the applicable requirements of— (1) Part 170 of this chapter, except subparts G and H; and (2) Part 171 of this chapter, subparts A and B. Vessel owner installed a collapsible awning over the exposed bow seating and side curtains around the perimeter of the vessel. 1) Submit to the Marine Safety Center the height, length, and width of these installed items for MSC to calculate for: A = projected lateral area in square feet (square meters) of the portion of the vessel and deck cargo above the waterline as described by 46 CFR 170.170(a) Weather criteria; 2)Provide the attending Marine Inspector proof of the required submission.
46 CFR 178.310(a)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International rules. Mast light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules.
46 CFR 183.420
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Bilge Pumps located in the aft section of the port and starboard hulls are not UL rated. Wire the pumps so that they can only be manually activated, or replace them with UL approved pumps.
46 CFR 182.520(e)(1)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 November 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Fuses for the bilge pumps are blade type fuses. Provide proper installation of cartridge type fuses for the bilge pump connections.
46 CFR 183.380
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 November 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have A splice made with a pressure type connector to a flexible lead or conductor. Wires under operating station were spliced incorrectly. Rewire spliced wires.
46 CFR 183.340(g)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Lights on added indication panel not in good working order. Remove added panel and use original indicators or fix indicating lights so that each pump in automatic mode is indicated.
46 CFR 182.530(c)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2022
Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. The floating water light on board the vessel was not operating properly. Replace water light. Vessel is restricted to daylight operations only.
46 CFR 180.70(d)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2022
Resolved
Electrical equipment must be installed to protect from electrical hazards. Grounding wire on starboard outboard engine is missing. Replace grounding wire.
46 CFR 183.200
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2022
Resolved
A drip pan fitted with flame screen must be installed under gasoline strainers. No drip pans on either side. Install drip pans.
46 CFR 182.455(b)(6)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2022
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Fuel lines held by multiple zip-ties and not secured. Secure fuel lines.
46 CFR 182.455(b)(3)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 October 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. In accordance with manufacturer and UL rating, a bracket must be provided. Provide bracket for portable fire extinguisher.
46 CFR 181.500(a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2022
Resolved
Each vessel must have permanent draft marks at each end of the vessel or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel must be marked IAW 46 CFR 185.602(c)
46 CFR 185.602(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Port outboard engine gasoline fuel primer bulb wasted and actively leaking. Replace fuel lines.
46 CFR 182.100
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 December 2021
Resolved
EAP Training Program: Supervisory personnel must receive at least 60 minutes of training. Prove required training was conducted to the satisfaction of the attending MI.
46 CFR 16.401(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2021
Resolved
Each life jacket must be marked with Type I retro-reflective tape material. Several life jackets retro-reflective tape missing. Corrected in the presence of the attending MI.
46 CFR 185.604(h)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 December 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Port bilge alarm light is not operational.
46 CFR 182.530(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 December 2020
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Flame screens on port and starboard fuel tank vents were absent. Install flame screen mesh on fuel vents.
46 CFR 182.450(e)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 December 2020
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that: the pump is permanently mounted. Properly mount the port bilge pump to the satisfaction of the Marine Inspector.
46 CFR 182.520(e)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 December 2020
Resolved
Vessel must be provided with satisfactory arrangement
for draining any watertight compartment. Vessel’s port
aft manual bilge pump was wasted and inoperable. Replace
manual bilge pump.
46 CFR 182.500
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 December 2020
Resolved
Fuses in electrical systems must be of the cartridge type only. Fuses for the bilge pumps are blade type fuses. Provide proper installation of cartridge type fuses in the electrical system onboard the vessel.
46 CFR 183.380
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2018
Resolved
Provide individual visual alarm for each unmanned spaces with high level bilge alarm. A visual and audible alarm must be provided at the operating station to indicate a high water level in each of unmanned spaces.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 5 December 2017
Resolved
Fuses must be of the cartridge type only and be listed by the Underwriters Laboratories. Replace all glass fuses with UL listed fuses. Replace all blade type fuses with cartridge type UL listed fuses. Replace ANL fuse with UL listed fuse.
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 December 2017
Resolved
Conductors in power and lighting circuits must be No. 14 AWG or larger. Conductors in power and lighting circuits must be listed by UL as UL Boat or UL Marine cable or meet IEEE 45 standards. Wiring for onboard stereo speakers is No. 18 AWG and does not meet the specifications for UL Boat or UL Marine cable. Replace all wiring in power and lighting circuits smaller than No. 14 AWG.
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 December 2017
Resolved
All cable and wire must be installed in such a manner as to avoid chafing and other damage. If protected by metal coverings or other suitable means, horizontal pipes used for protections shall have .25 inch holes for drainage every 5 feet. Inspector found cable and wiring installed centerline of the vessel in areas that would cause chafing. Protect wiring to avoid chafing or other damage.
Documentation › Logs/Records › Drug Test Records
Issued 5 December 2017
Resolved
Employers must maintain records of chemical tests and must make these records available to the Coast Guard upon request. Provide pre-employment test records for all crew on the vessel. Provide a copy of contract or proof of enrollment in a the company drug consortium along with a list of employees covered.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 February 2011
Resolved
Properly log inspections of life saving equipment.
Operations/Management › Drills/Instruction › Fire
Issued 24 February 2011
Resolved
Provide and post emergency instructions.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 February 2011
Resolved
Provide CG approved first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 24 February 2011
Resolved
Provide current navigation chart for areas of operation.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 February 2010
Resolved
Supervisor has not completed the 1 hour EAP training.
Engineering › Reduction Gearing/Clutches › Gear
Issued 22 January 2009
Resolved
Stbd engine failed to provide aft propulsion.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 January 2009
Resolved
Found expired battery installed in ring buoy light. Replace with new battery.
Navigation › Piloting/Steering › Marine Charts
Issued 22 January 2009
Resolved
Found nav chart and light listed outdated. Provide current revisions.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 22 January 2009
Resolved
Found chaffed and corroded grounding distribution wire under center console. Repair to standard condition.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 22 January 2009
Resolved
Owner could not provide evidence of MIS submission. Provide proof of submission of MIS report for 2007 and 2008.
Engineering › Gasoline Engine (propulsion) › Combustion Chamber (2 stroke)
Issued 20 March 2008
Resolved
The stbd outboard engine experiences oil pressure alarms and shuts down, as observed by a marine inspector in February 2008 during the annual inspection and again in March 2008 subsequent to near-grounding event at Heeia Kea Harbor. Make a permanent repair to the stbd engine through professional servicing prior to operating with passengers.
Documentation › Certificates/Documents › FCC SSL
Issued 11 January 2007
Resolved
Provide valid FCC safety certificate.
Documentation › Logs/Records › Drug Test Records
Issued 11 January 2007
Resolved
Provide material for DAPI audit.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 January 2007
Resolved
Prove proper operation of compass light.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 January 2007
Resolved
Provide corrosion resitant clip and provide retro tape.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 January 2007
Resolved
Place all required documents under glass.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 January 2007
Resolved
Provide first aid cards for crew.
Engineering › Fuel Oil Service System › Ventilation
Issued 11 January 2007
Resolved
Provide flame screen for port fuel tank.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 November 2005
Resolved
Owner was unaware that he needed it, cause only intends to operate during daylight hours. Owner was given the option to either get light on life-ring or COI can be amended to show daylight operations only. Owner said that he will get light for life-ring.