MAURY USCG vessel records Sign in
← All vessels

ANGEL 22

ANGEL 22 is a 1998 tank ship. The Coast Guard has recorded 27 inspections since 2005, most recently in February 2012, along with 11 deficiencies and 10 operational controls.

Records from 2005 to 2012. Most recent: inspection, 15 February 2012.

Built
1998
Last inspected
15 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9191230 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
779710
Flag
BAHAMAS, THE
—
Maury page id
psix-779710

Inspections, by type

…with no type recorded10
Years with a record 6 calendar years (2005–2012)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5483 - Convention (Subpart B), Gross Ton
2602 - Convention (Subpart B), Net Ton
11790 - Displacement, Ton
8823 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

15 February 2012 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination · COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4240946
14 February 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4240983
16 February 2011 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3946741
24 January 2011 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3931571
17 November 2010 Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 3893561
9 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3846251
7 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3840893
22 February 2010 COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3683720
22 January 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3668088
20 January 2010 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3666953
22 April 2007 MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2912906
16 April 2007 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2908791
5 April 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2902249
22 March 2007 NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2892879
11 March 2007 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2885593
27 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2809330
8 October 2006 COC-CHEM Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2796029
27 September 2006 Ballast Water Examination · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2787988
26 September 2006 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2787991
23 August 2006 ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2757573
23 August 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2757655
22 August 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2756611
26 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2540921
16 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2494248
10 September 2005 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2487082
11 August 2005 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2458102
10 August 2005 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2458119

Deficiency record · 11

Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 16 February 2011 Resolved
Vessel's #2 starboard cargo tank high level alarm is inoperative. Prior to loading cargo in the #2 starboard cargo tank vessel must submit proper documentation form certificate issuing authority attesting to the proper repair and operation of the #2 starboard high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Resolution: Vessel submitted class report attesting to proper operations
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 16 February 2011 Resolved
Vessel does not have stud installed in vapor control flanges. Prior to conducting cargo operations requiring vapor control vessel must submit proper documentation form certificate issuing authority attesting to the proper installation of the vapor control flange studs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Resolution: Vessel submitted class report attesting to installation of stud.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 February 2011 Resolved
Vessel's ODME is inoperative. Prior to departure vessel must submit proper documentation from certificate issuing authority attesting to the proper repair and operation of the ODME.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2011
Resolution: Recieved class report attesting to installation of new ODME, working properly.
Lifesaving › Inflatable Liferafts › Painter
Issued 16 February 2011 Resolved
Life saving appliances shall be in working order & ready for immediate use. Vessel liferaft painter was fastened to ship, not properly installed. (SOLAS '04 CH III REG 20.2)
Action required: 705 - Other - as specified
Resolved 16 February 2011
Resolution: Def was corrected on the spot. painter line was disconnected from ship and added to wink link as stowage/design indicated.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 January 2011 Resolved
See Narrative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2011
Resolved 21 March 2011
Resolution: MY OFFICE RECEIVED CLASS REPORT AND NEW FULL TERM IOPP CERTIFICATE ATTESTING TO PROPER ORDER OF ODME.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 9 September 2010 Resolved
It was reported that the CLIPPER TRINIDAD was experiencing difficulties with their propulsion system. An Operational Control was placed on the vessel requiring them to fix their propulsion system prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2010
Resolution: The air starting valve for the no. 1 cylinder had been replaced with spares found on board the vessel. ABS verified that the main diesel engine had been tested and considered acceptable. They also witnessed the operation of the start functions.
Fire Fighting › Fixed Deck Foam System › Foam Applicators
Issued 22 March 2007 Resolved
Vessel has outstanding unsatisfactory foam analysis report for January 09,2007. Vessel shall not conduct cargo operations until the Captain of the Port receives an alternate fire fighting plan equal to the ships foam fire fighting system capabilities. Vessel shall refill foam system to 105% and submit a foam analysis report verified and approved by an attending classification society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2007
Resolution: Received Class Report and foam analysis certificate attesting to vessel having sufficient foam concentrate.
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 22 March 2007 Resolved
Vessel failed to report a hazardous condition to the U.S. Coast Guard as per 33CFR160.215. Vessel required to submit a Letter of Undertaking in th amount of $32,500.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Resolution: Received Letter of Undertaking in the amount of $32,500.
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 8 October 2006 Resolved
#2 foam/water fire fighting cannon inoperative. Vessel is to correct prior to departure to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2006
Resolved 9 October 2006
Resolution: Received class report attesting to proper operation of #2 foam/water fire fighting cannon.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 10 September 2005 Resolved
Class to attest to the proper operation of High (95%) and Overfill (98%) alarms prior to loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 September 2005
Resolved 26 November 2005
Resolution: A report was recieved from the class (NKK) Clearing the deficiency for the high level and overfill alarms on the Cargo tanks.
Lifesaving › Launching Appliances › Davit
Issued 10 September 2005 Resolved
Stbd. lifeboat davit brake release mechanism is sticking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2005
Resolved 12 September 2005
Resolution: Class NKK attended the vessel. Crew greased all moving parts and operation test was carried out with satisfactory result.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.