Records from 2005 to 2016. Most recent: inspection, 28 March 2016.
Inspection history · 46
28 March 2016
COI Inspection
Physical examination · Activities Europe · Activity 5841638
18 July 2012
ACP Annual Oversight
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4383087
3 February 2012
Type not recorded
No type recorded · Activities Europe · Activity 4239669
19 January 2012
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4227580
9 December 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4205213
9 September 2011
Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 4082830
28 July 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4097254
21 July 2011
DAPI Audit · ACP COI Oversight · Ballast Water Examination · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4077346
16 July 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4083044
8 July 2011
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4171777
20 November 2010
Annual Inspection · DAPI Audit · Ballast Water Examination · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3896597
18 October 2010
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3872671
23 February 2010
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3684898
23 February 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3692570
11 December 2009
Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3648571
7 May 2009
Plan Review (Other than "T")
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3832694
30 March 2009
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3443116
27 February 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3427964
6 February 2009
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3413593
27 December 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3385314
23 December 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3384273
21 October 2008
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3348759
10 September 2008
DAPI Audit · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3320989
3 July 2008
ACP Periodic Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3255579
27 March 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3172510
14 January 2008
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3130421
10 January 2008
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3126966
3 January 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3126143
18 October 2007
Damage Survey
Physical examination · Activities Europe · Activity 3082236
15 October 2007
Damage Survey
Physical examination · Activities Europe · Activity 3081407
25 September 2007
MTSA/ISPS Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3065548
7 May 2007
Type not recorded
No type recorded · Activities Europe · Activity 2923925
28 March 2007
Internal Structural Exam · COI Inspection · MTSA/ISPS Verification · Deficiency Check · Hull Examination
Physical examination · Activities Europe · Activity 2896618
5 March 2007
Periodic Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2882499
12 January 2007
Deficiency Check
Physical examination · Activities Europe · Activity 2854542
13 October 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2889299
5 October 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2889306
26 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2634118
3 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2617771
24 February 2006
Type not recorded
No type recorded · Activities Europe · Activity 2623614
16 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586421
4 February 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2679626
6 December 2005
Type not recorded
No type recorded · Activities Europe · Activity 2596634
2 November 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2526990
20 October 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2518753
9 August 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2457046
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 18 July 2012
Resolved
Provide new Cargo Ship Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 19 July 2012
Resolution: Received valid CSSRC, scanned into MISLE.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2012
Resolved
Replace pipe for after cooler on chemical cleaning system - pipe has 04 jubilee patches.
Action required: 705 - Other - as specified
Due 20 August 2012
Resolved 20 July 2012
Resolution: Pipe patches replaced with welding IAW with class rules. See Lloyd''''''''s Register class report dated 20JUL12.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2012
Resolved
Replace guards on: Bilge and Ballast pump; on chemical cleaning after cooler; on fresh water emergency cooling line. Verify other system gauges are in good working order, if not, replace them.
Action required: 705 - Other - as specified
Due 20 August 2012
Resolved 20 July 2012
Resolution: Gauges replaced as per Lloyd''''''''s Register class report dated 20JUL12.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 21 July 2011
Resolved
Repair fractured pipe from the main engine lube oil pump to the settling tank.
Action required: 705 - Other - as specified
Due 21 August 2011
Resolved 9 September 2011
Resolution: Verified section of piping had been replaced with new type and kind.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 July 2011
Resolved
Demonstrate proper operation of the OWS.
Action required: 705 - Other - as specified
Due 21 August 2011
Resolved 28 July 2011
Resolution: received report from C/E as to the proper operation of OWS.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 21 July 2011
Resolved
Renew spark arrester piping where soft patch has been applied.
Action required: 705 - Other - as specified
Due 21 August 2011
Resolved 9 September 2011
Resolution: Verified permanent repairs had been made on spark arrester piping.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 11 July 2011
Resolved
Face masks (3) for the SCBA are showing deterioration (cracking) in the rubber around the face piece and head straps. All face masks are still forming tight seals and are in service. Face masks are to be replaced to the satisfaction of USCG inspector or class.
Due 21 August 2011
Resolved 9 September 2011
Resolution: Inspected firemans outfits and noted face masks had been replaced.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 11 July 2011
Resolved
The hospital space has missing ceiling tiles. The overhead has exposed insulation material and wire splice for missing light that was mounted to the ceiling, both these conditions pose health hazard to a patient utilizing the hospital space. Repairs to be made to the satisfaction of USCG inspector or class surveyor.
Due 10 January 2012
Resolved 18 January 2012
Resolution: received tech report stating the tiles have been replaced.
Construction/Loadline › Structures › Deck Plating
Issued 11 July 2011
Resolved
The aft cargo ramp has a 8 inch crack on a frame, the lower starboard side, where the foot ramp portion attaches to the mid ramp section (outboard side of ramp railing). Crack does not appear to be a new crack and has corrosion around it. Issued an 835 to make repairs to the ramp. Repairs to be made to the satisfaction of USCG inspector or class surveyor.
Due 8 August 2011
Resolved 9 September 2011
Resolution: Witnessed replacement of cargo ramp foot.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 November 2010
Resolved
Seawater recirc pipe located on stbd side of bottom engine flat at frame 50, weaping on hull side. Repair/Replace
Action required: 705 - Other - as specified
Due 29 January 2011
Resolved 5 January 2011
Resolution: Received e-mail from [name withheld], Port [name withheld] with attached proof of repairs to outstanding defiencies.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 20 November 2010
Resolved
Current air charging system for self contained breathing apparatus bottles unable to recharge bottles in a timely fashion. Upgrade charging system or supply an additional air cylinder for each apparatus.
Action required: 705 - Other - as specified
Due 26 December 2010
Resolved 5 January 2011
Resolution: Received e-mail from [name withheld], Port [name withheld] with attached proof of repairs to outstanding defiencies.
Deck/Cargo › Cargo Stowage › General
Issued 20 November 2010
Resolved
Sde view profile function on the Loadmaster program is inadequate-specifically the cargo holding cells are blacked out. Upgrade system to allow proper operation in all modes to allow for the verificationof all cargo and ballast.
Action required: 705 - Other - as specified
Due 29 January 2011
Resolved 5 January 2011
Resolution: Received e-mail from [name withheld], Port [name withheld] with attached proof of repairs to outstanding defiencies.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 23 February 2010
Resolved
Prove proper operation of the inboard ship service generator and main circuit breaker to the satisfaction of the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 March 2010
Electrical › Electric Generation Source (service) › Generator
Issued 30 March 2009
Resolved
While in port outboard generator suffered a short in the stator winding resulting in vessel going dark. Must show operation of two generators with the aggraegate capacity to provide sufficient power for all ships service loads.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2009
Resolved 5 April 2009
Resolution: Installed 800 KW generator on deck. Demonstrated to class surveyor (LR) proper operation.
Electrical › Electric Generation Source (service) › Generator
Issued 30 March 2009
Resolved
Demonstrate proper operation of repaired generator.
Action required: 705 - Other - as specified
Due 5 May 2009
Resolved 6 May 2009
Resolution: New generator installed and satisfactory load test conducted.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 6 February 2009
Resolved
Damage to stern tube outer seal resulted in all stern tube oil to be flushed out into engine room through head tank vent and an ingress of sea water approxamately 1 - 3 liters per hourwhen in heavy seas. Leak stoped when vessel was in calmer seas. Following discussions with Class Surveyor and seal rep., vessel to by drydocked following discharge of cargo in Brunswick, GA. Class to provide report.
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 18 February 2009
Resolution: Received class report attesting to proper repairs. See narative for details.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 December 2008
Resolved
Vessel reported that secondary "S-band" radar was inoperable. LOD 30-08 was issued to vessel to enter the port of Baltimore. Vessel is to repair the secondary radar prior to departure and submit technician's report to attest.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2008
Resolution: SATISFACTORY TECH REPORT RECEIVED.
Fire Fighting › Fire Hydrants › Condition
Issued 10 September 2008
Resolved
Repair or replace leaking fire main plug at station 55 in lower engine room.
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 20 October 2008
Fire Fighting › Fire Main › Pressure
Issued 10 September 2008
Resolved
Provide fire main pressure indicator at remote control station bridge to meet requirements for automated vital systems.
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 20 October 2008
Engineering › Steam System (auxiliary) › Valve
Issued 10 September 2008
Resolved
Steam leak was notice in way of SV-17 and SV-16 located in the lower engineroom. SV-17 leaks worse then SV-16 but both cause safety concern. Repair or replace valve to eliminate safety risks.
Action required: 705 - Other - as specified
Due 11 October 2008
Resolved 20 October 2008
Accommodation/Occupational Safety › Heating › Piping
Issued 10 September 2008
Resolved
Hot water PVC piping above bed in hospital has temporary repair made of hose clamps and hose. Make repairs to piping to restore as original. Port Engineer ([name withheld]) for vessel currently intends to replace all piping in accomodation spaces during next availability. Please address this def during next annual inspection.
Action required: 705 - Other - as specified
Due 31 October 2009
Resolved 11 December 2009
Resolution: Received work orders from last yard period confirming that the piping had been replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 January 2008
Resolved
Prove proper operation of low pressure CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2008
Resolution: Tested system satisfactorily with UNITOR tech rep.
Fire Fighting › Fire Main › Condition
Issued 10 January 2008
Resolved
Prove proper operation of main fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2008
Resolution: Tested main fire pump satisfactorily.
Lifesaving › Launching Appliances › Davit
Issued 10 January 2008
Resolved
Prove proper operation of rescue boat launching appliance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2008
Resolution: Tested rescue boat davit satisfactorily.
Construction/Loadline › Hull › Transverse Frame
Issued 18 October 2007
Resolved
Make permanent repairs to Port side frames 171 to 180 damage. Completion date will be based upon the results of the hull damage report.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 18 November 2007
Resolution: Repairs completed Bremerhaven Germany
Construction/Loadline › Hull › Transverse Frame
Issued 18 October 2007
Resolved
Port side deck 5 in way of frames 171-180 crop and renew 6 tripped brackets as marked crop and renew web of 2 deep frames as marked
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2007
Resolved 19 November 2007
Construction/Loadline › Hull › Transverse Frame
Issued 18 October 2007
Resolved
Starboard side deck 5 in way of frames 183-186 crop and renew 3 tripped brackets and stiffeners as marked crop and renew web of deep frame as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2007
Resolved 19 November 2007
Engineering › Steam System (auxiliary) › Valve
Issued 25 September 2007
Resolved
Show proper operation of steam valve for use in f/o heating to no. three f.o.t. Excessive leaking.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 26 September 2007
Resolution: Gasket replaced and proper operation demonstrated.
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2007
Resolved
Demonstrate proper operation of bilge and ballast pump discharge gauge. excessive leaking at gauge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 26 September 2007
Resolution: Gauge line replaced and tested sat.
Construction/Loadline › Hull › Stringer
Issued 25 September 2007
Resolved
Renew coating system at starboard forward corner of engine room along the longitudinal stringer where condensation and other water accumulates. remove and provide a means to keep clean and dry.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 31 October 2007
Resolution: Scale removed and coatings applied.
Construction/Loadline › Structures › Door
Issued 25 September 2007
Resolved
Demonstrate proper operation of door latch for the engine room emergency egress. The throw sticks and allows door to swing open.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 26 September 2007
Resolution: Latch repaired and proper operation demonstrated.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 25 September 2007
Resolved
Provide bouyant floats suitable for use with ships line throwing appliances.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 31 October 2007
Resolution: Buoyant floats provided.
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2007
Resolved
Submit repair proposal for shell/structural damage at the following locations;
1, inset, engine room stbd frame 40-41.
2. inset, deck five cargo spaces stbd frames 183-186.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 31 October 2007
Resolution: Repair submited to class LR.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 25 September 2007
Resolved
Vessel to maintain continious live watch as established by the master sufficeint to ensure the safety of the vessel until automation procedures including tech review and subsequent testing and verification by local OCMI is completed.
Action required: 705 - Other - as specified
Due 30 August 2008
Resolved 10 September 2008
Resolution: All test were conducted iaw manual and items noted in MSC ltr (Serial: E2-0702155) dated July 9, 2007 were satisfied. [name withheld] has stamped procedure "approved" dated 11Sep08.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 12 January 2007
Resolved
Provide to this office an itemized list of all loads & their required amperage for the transitional source of emergency power as defined in SOLAS chapter II-1 regulation 43, with an endorsement from Llyods Register that the 800 amperage battery bank now in place is adequate or return the system to the 1200 amperage hour battery bank in place before the fire of 20 Jan 06.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 7 May 2007
Resolution: Received Fax attesting to repairs being completed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 November 2006
Resolved
Demonstrate proper operation of the oily water separator to the satisfaction of an attending Coast Guard Marine Inspector or Lloyds Register Surveyor. The overboard discharge valve must remain locked in the closed position and the ship must maintain adequate tank age in the bilge holding tanks to accommodate all oily waste generated from the engine room.
Action required: 705 - Other - as specified
Due 20 November 2006
Resolved 21 November 2006
Resolution: Cleared by Sector Charleston 2826249
Engineering › Bilge Water Management System › Piping
Issued 6 November 2006
Resolved
Crop and renew the emergency bilge suction piping in way of the two soft patches to the satisfaction of attending Coast Guard Marine Inspector or Lloyds Register Surveyor.
Action required: 705 - Other - as specified
Due 6 December 2006
Resolved 21 November 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 September 2006
Resolved
Replace the existing lifejackets with Coast Guard approved life jackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 20 October 2006
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 30 September 2006
Resolved
Demonstrate the proper operation of the rescue boat spotlight.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 30 September 2006
Resolved
Replace the gasket on the rescue boat deck hatch.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 30 September 2006
Resolved
Mount a sledge hammer in way of the anchor chain detachable link.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 30 September 2006
Resolved
Provide Seacoast Servicing Technician report attesting to the proper operation of the Voyage Data Recorder after installation.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 6 November 2006
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 30 September 2006
Resolved
Install a gyrocompass repeater in the steering gear room.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Engineering › Pressure Vessel › Relief Valve
Issued 30 September 2006
Resolved
Bench test the Emergency Air Receiver (data plate and lead restraint needed), Air Receiver for Emergency Closure Valves and the General Service pressure vessels relief valves.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Electrical › Electric Generation Source (service) › Power Requirement
Issued 30 September 2006
Resolved
Adjust the main generators so that they share the load equally when operating in parallel.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 30 September 2006
Resolved
Repair the outboard generators exhaust so that it does not leak.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Engineering › Fuel Oil Service System › Valve
Issued 30 September 2006
Resolved
Demonstrate proper operation of the fuel oil shut-off valves.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 September 2006
Resolved
Blank system, current, circuit and missing fuse openings on the Frequency Converter - Thyristor Panel.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 30 September 2006
Resolved
Itemize systems on the emergency battery (UPS) and provide [name withheld] verified load analysis documenting compliance with SOLAS II-1.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 September 2006
Resolved
Install Coast Guard approved wiring in way of the main generator and fire damage.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Fire Fighting › Fire Main › Valves
Issued 30 September 2006
Resolved
Lap or replace the fire main in way of the emergency fire pump.
Due 14 October 2006
Resolved 20 October 2006
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 30 September 2006
Resolved
Replace the rotten manila rope on starboard embarkation ladder.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 20 October 2006
Engineering › Pressure Vessel › Weld
Issued 30 September 2006
Resolved
Make the Aft Start Air Receiver, Emergency Air Receiver and General Service air Receiver ready for inspection or hydrostatically test to 125% of the MAWP.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 20 October 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 30 September 2006
Resolved
Provide Unitor Servicing report for the low pressure CO2 system.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 30 September 2006
Resolved
Hydrostatically test the auxiliary boiler and exhaust gas boiler piping.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Mount
Issued 30 September 2006
Resolved
Make the auxiliary boiler water and fireside and mounts ready for inspection.
Action required: 705 - Other - as specified
Due 14 October 2006
Resolved 14 October 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 30 September 2006
Resolved
Bench test the auxiliary and exhaust gas boilers safety and relief valves.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 September 2006
Resolved
Produce Lloyds Register letter NAO/050538JNC and approved automated system testing procedures.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 September 2006
Resolved
Demonstrate proper operation of the oily water separator.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 6 November 2006
Lifesaving › Line-Throwing Appliances › Lines
Issued 30 September 2006
Resolved
Provide line throwing apparatus with 1500 feet auxiliary line.
Action required: 705 - Other - as specified
Due 14 November 2006
Resolved 20 October 2006
Lifesaving › Launching Appliances › Falls
Issued 30 September 2006
Resolved
Load test the life raft, rescue boat and free fall davit and falls.
Due 14 November 2006
Resolved 6 November 2006