Records from 2005 to 2017. Most recent: inspection, 11 September 2017.
Inspection history · 39
11 September 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6264115
9 June 2017
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6170306
28 January 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6073297
26 January 2017
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6077889
27 August 2016
Type not recorded
No type recorded · Station Cleveland Harbor · USCG Great Lakes District (CGD-GL) · Activity 5984760
11 March 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5832626
3 March 2016
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5826364
4 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5809412
10 May 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4307670
16 February 2012
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4245846
12 January 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4223890
2 January 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4217066
2 January 2012
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4217893
26 September 2011
MARPOL Annex VI Survey · MARPOL Annex V Examination · MARPOL Annex IV Survey · MARPOL Annex I Examination · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4152872
23 September 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4167108
19 September 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4149189
11 September 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4156630
29 January 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3935568
10 February 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3677963
7 July 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3525382
10 February 2009
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3415640
6 December 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3376043
1 December 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3372310
15 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3363554
15 October 2008
ACP Annual Oversight · Ballast Water Examination · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3345476
7 October 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3345229
21 July 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276888
6 February 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3143031
4 January 2008
MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3124740
1 October 2007
MTSA Verification · Ballast Water Examination · MARPOL Annex I Examination · ACP Annual Oversight · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3070671
16 April 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2908665
16 April 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2908673
22 January 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2860028
8 January 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2852410
17 August 2006
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2750681
25 May 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2661425
25 April 2006
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2632874
14 March 2006
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2602294
21 September 2005
Initial Certification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2498079
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 January 2012
Resolved
Make proper repairs to inoperable X band radar. Provide proof of proper operation to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 January 2012
Resolution: Accepted tech report from Anyboat Marine electronics.
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 26 September 2011
Resolved
While replacing a connecting rod (service bulletin related item) the crew discovered a significant amount of metal shavings in the main engine sump. It has been determined that the #4 cam follower bushing is deteriorated and the source of the bulk of the metal shavings; further assesment is pending. The operator is required to make all repairs necessary to render the main engine fit for service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 September 2011
Resolved
The #2 SSDG breaker trips intermittently. Make necessary repairs and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 26 September 2011
Resolved
The shaft generator coupling suffered a catastrophic failure and the generator broke free from it's mounts due to vibration. Make repairs all necessary repairs to the shaft generator and prove proper operation.
Due 1 February 2012
Resolved 16 February 2012
Resolution: Cleared by class (GL) report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 September 2011
Resolved
Temporary repairs were made to the OWS while underway; make permanent repairs to the OWS prior to the next foreign voyage.
Due 26 October 2011
Resolved 2 October 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 September 2011
Resolved
The CO2 fixed fire fighting system for the galley hood vent ducting has not been serviced since June of 2009; conduct the annual service of the system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2011
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 26 September 2011
Resolved
The closed circuit television system required by the vessels exemption certificate is not operational; make necessary repairs.
Due 26 October 2011
Resolved 2 October 2011
Construction/Loadline › Hull › Bottom Plating
Issued 1 December 2008
Resolved
Vessel was involved in a Grounding where the vessel's bottom presented slight longitudinal scratches, at port side, between frames 47 and 122 at about 1.5 meters from the bilge keel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 December 2008
Resolution: Class Report submitted. Class report indicates that "no indents and/or deformation were verified in the vessel''s bottom plaiting. No Conditions of Class was issued."
Lifesaving › Lifeboat › Markings
Issued 7 January 2008
Resolved
The name and port of registry of the ship to which the lifeboat belongs shall be marked on each side of the lifeboat's bow in block capitals to the satisfaction of USCG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 6 February 2008
Resolution: Vessel provided photographic evidence that the proper markings have been affixed to the lifeboat.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 7 January 2008
Resolved
The vessel's forward life raft container is not marked with the number of persons it is permitted to carry. Mark to satisfaction of USCG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 6 February 2008
Resolution: Vessel provided photographic evidence that the proper markings have been affixed to the 100M life raft container.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 January 2008
Resolved
Several self closing fire doors throughout the accommodation found inoperable, to include doors leading from main ladder well to main deck, engineer deck, officer's deck, upper deck, and wheel house. Address all doors in accommodation ladder well and all doors to main deck. Prove proper operation to satisfaction of attending USCG Marine Inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2008
Resolution: Verified that the main deck, boat deck and engineering deck fire doors in the main ladder way all close/operate correctly. All new door closing hardware was installed and adjusted.
Construction/Loadline › Markings › Load Line Mark
Issued 4 January 2008
Resolved
Both the port and starboard deck lines are pained blue on a blue hull. The lines are to be pained white or yellow on a dark ground. Mark to satisfaction of USCG Marine Inspector
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 7 February 2008
Resolution: Vessel submitted photographic evidence of both deck lines properly marked.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 September 2005
Resolved
Conduct abandon ship drill in the prescence of the attending Coast Guard Inspector.
Due 28 September 2005
Resolved 17 October 2005
Resolution: Cleared by MSU Savannah.
Operations/Management › Drills/Instruction › Fire
Issued 21 September 2005
Resolved
Conduct fire drill in the prescence of the attending Coast Guard Inspector.
Due 28 September 2005
Resolved 17 October 2005
Resolution: Cleared by MSU Savannah.