MAURY USCG vessel records Sign in
← All vessels

INDUSTRIAL CHIEF

INDUSTRIAL CHIEF is a 2000 freight ship. The Coast Guard has recorded 39 inspections since 2005, most recently in September 2017, along with 14 deficiencies, 4 operational controls and 7 casualty investigations between 2008 and 2013.

Records from 2005 to 2017. Most recent: inspection, 11 September 2017.

Built
2000
Last inspected
11 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9213947 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC7175
781429
Flag
MARSHALL ISLANDS
367067440 (licence lapsed)
Maury page id
psix-781429

Inspections, by type

…with no type recorded15
Years with a record 10 calendar years (2005–2017)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7252 - Convention (Subpart B), Gross Ton
2982 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7175MMSI 367067440 · cancelled · compulsorily equipped · granted 17 September 2005, cancelled 19 March 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

11 September 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6264115
9 June 2017 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6170306
28 January 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6073297
26 January 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6077889
27 August 2016 Type not recorded
No type recorded · Station Cleveland Harbor · USCG Great Lakes District (CGD-GL) · Activity 5984760
11 March 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5832626
3 March 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5826364
4 February 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5809412
10 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4307670
16 February 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4245846
12 January 2012 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4223890
2 January 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4217066
2 January 2012 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4217893
26 September 2011 MARPOL Annex VI Survey · MARPOL Annex V Examination · MARPOL Annex IV Survey · MARPOL Annex I Examination · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4152872
23 September 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4167108
19 September 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4149189
11 September 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4156630
29 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3935568
10 February 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3677963
7 July 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3525382
10 February 2009 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3415640
6 December 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3376043
1 December 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3372310
15 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3363554
15 October 2008 ACP Annual Oversight · Ballast Water Examination · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3345476
7 October 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3345229
21 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276888
6 February 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3143031
4 January 2008 MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3124740
1 October 2007 MTSA Verification · Ballast Water Examination · MARPOL Annex I Examination · ACP Annual Oversight · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3070671
16 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2908665
16 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2908673
22 January 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2860028
8 January 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2852410
17 August 2006 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2750681
25 May 2006 MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2661425
25 April 2006 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2632874
14 March 2006 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2602294
21 September 2005 Initial Certification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2498079

Deficiency record · 14

Navigation › Collision/Grounding Avoidance › Radar
Issued 2 January 2012 Resolved
Make proper repairs to inoperable X band radar. Provide proof of proper operation to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 January 2012
Resolution: Accepted tech report from Anyboat Marine electronics.
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 26 September 2011 Resolved
While replacing a connecting rod (service bulletin related item) the crew discovered a significant amount of metal shavings in the main engine sump. It has been determined that the #4 cam follower bushing is deteriorated and the source of the bulk of the metal shavings; further assesment is pending. The operator is required to make all repairs necessary to render the main engine fit for service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 September 2011 Resolved
The #2 SSDG breaker trips intermittently. Make necessary repairs and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 26 September 2011 Resolved
The shaft generator coupling suffered a catastrophic failure and the generator broke free from it's mounts due to vibration. Make repairs all necessary repairs to the shaft generator and prove proper operation.
Due 1 February 2012
Resolved 16 February 2012
Resolution: Cleared by class (GL) report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 September 2011 Resolved
Temporary repairs were made to the OWS while underway; make permanent repairs to the OWS prior to the next foreign voyage.
Due 26 October 2011
Resolved 2 October 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 September 2011 Resolved
The CO2 fixed fire fighting system for the galley hood vent ducting has not been serviced since June of 2009; conduct the annual service of the system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2011
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 26 September 2011 Resolved
The closed circuit television system required by the vessels exemption certificate is not operational; make necessary repairs.
Due 26 October 2011
Resolved 2 October 2011
Construction/Loadline › Hull › Bottom Plating
Issued 1 December 2008 Resolved
Vessel was involved in a Grounding where the vessel's bottom presented slight longitudinal scratches, at port side, between frames 47 and 122 at about 1.5 meters from the bilge keel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 December 2008
Resolution: Class Report submitted. Class report indicates that "no indents and/or deformation were verified in the vessel''s bottom plaiting. No Conditions of Class was issued."
Lifesaving › Lifeboat › Markings
Issued 7 January 2008 Resolved
The name and port of registry of the ship to which the lifeboat belongs shall be marked on each side of the lifeboat's bow in block capitals to the satisfaction of USCG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 6 February 2008
Resolution: Vessel provided photographic evidence that the proper markings have been affixed to the lifeboat.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 7 January 2008 Resolved
The vessel's forward life raft container is not marked with the number of persons it is permitted to carry. Mark to satisfaction of USCG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 6 February 2008
Resolution: Vessel provided photographic evidence that the proper markings have been affixed to the 100M life raft container.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 January 2008 Resolved
Several self closing fire doors throughout the accommodation found inoperable, to include doors leading from main ladder well to main deck, engineer deck, officer's deck, upper deck, and wheel house. Address all doors in accommodation ladder well and all doors to main deck. Prove proper operation to satisfaction of attending USCG Marine Inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2008
Resolution: Verified that the main deck, boat deck and engineering deck fire doors in the main ladder way all close/operate correctly. All new door closing hardware was installed and adjusted.
Construction/Loadline › Markings › Load Line Mark
Issued 4 January 2008 Resolved
Both the port and starboard deck lines are pained blue on a blue hull. The lines are to be pained white or yellow on a dark ground. Mark to satisfaction of USCG Marine Inspector
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 7 February 2008
Resolution: Vessel submitted photographic evidence of both deck lines properly marked.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 September 2005 Resolved
Conduct abandon ship drill in the prescence of the attending Coast Guard Inspector.
Due 28 September 2005
Resolved 17 October 2005
Resolution: Cleared by MSU Savannah.
Operations/Management › Drills/Instruction › Fire
Issued 21 September 2005 Resolved
Conduct fire drill in the prescence of the attending Coast Guard Inspector.
Due 28 September 2005
Resolved 17 October 2005
Resolution: Cleared by MSU Savannah.

Casualty record · 7

6 December 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3376043
28 August 2009Routine · role: Involved in a Marine Casualty · activity 3579133
13 November 2009Routine · role: Involved in a Marine Casualty · activity 3636899
29 January 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3935568
23 April 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4296069
1 October 2012Routine · role: Involved in a Marine Casualty · activity 4471637
14 March 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4549944
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

OCEAN TITAN (2008–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.