Records from 2005 to 2011. Most recent: operational control imposed, 2 September 2011.
Inspection history · 29
2 September 2011
ISPS I Exam · COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4133622
2 September 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4134020
15 January 2011
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3925554
18 October 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3873801
17 October 2010
COE-Dockside
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3868391
27 December 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3384826
14 June 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3236375
5 June 2008
Annual Inspection · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3227027
12 March 2008
MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3163137
11 March 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3162562
5 December 2007
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3110180
15 October 2007
In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3080475
12 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2928518
9 March 2007
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Activities Europe · Activity 2835731
30 August 2006
Administrative Inspection
Administrative · Activities Europe · Activity 2763845
29 August 2006
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2762449
19 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2718432
12 May 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2647778
17 March 2006
Ballast Water Examination · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2596770
28 February 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2595344
15 February 2006
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2585422
23 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539764
25 October 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2521880
19 October 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2518315
17 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2516437
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501234
6 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2485394
6 September 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2485522
30 August 2005
COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2479123
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 June 2008
Resolved
Received notification of STBD anchor windlass is operable. Vessel must provide tugs of adequate horsepower to maintain control of the vessel in the event of an emergency during the inbound transit and any shifting within the Port.
Vessel shall submit a report from the Certificate [name withheld] attesting to the proper operation of the anchor windlass prior to departure from the Port of Houston
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2008
Resolved 15 June 2008
Resolution: Repair was made by replacing old brake pin with a new brake pin. Starboard Anchor Windlass was examined and operationally tested. All sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 12 May 2007
Resolved
Loss propulsion whle going astern bells.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2007
Resolution: Recieved class report attesting to proper operation of propulsion system.
Construction/Loadline › Markings › Load Line Mark
Issued 29 August 2006
Resolved
Vessel needs to paint it's load line.
Due 31 August 2006
Resolved 30 August 2006
Resolution: Vessel was witnessed at Packer ave with load line painted.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2006
Resolved
Make permanent repairs to the light fixture in way of main deck, aft at the emergency escape door, to the satisfaction of the class society.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 12 May 2006
Resolution: Cleared per class (ABS) report.
Electrical › Lighting (service) › Grounding Conductor
Issued 17 March 2006
Resolved
Make permanent repairs to explosion proof lighting in way of both life boat stations to the satisfaction of the class society surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 12 May 2006
Resolution: Cleared per class (ABS) report.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 17 March 2006
Resolved
Brake release inside starboard lifeboat is out of adjustment. Make proper adjustments prior to departing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2006
Resolved 18 March 2006
Resolution: Cleared by class
Construction/Loadline › Markings › Load Line Mark
Issued 17 March 2006
Resolved
Repaint the loadline marks and the vessel name in contrasting colors to the satisfaction of the class society surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 12 May 2006
Resolution: Cleared per class (ABS) report.
Engineering › Pressure Vessel › Relief Valve
Issued 17 March 2006
Resolved
Prove that all pressure relief valves on all pressure vessels and aux boiler are properly set and acceptable to the class society surveyor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 18 March 2006
Resolution: cleared by class
Engineering › Fuel Oil Service System › Piping
Issued 17 March 2006
Resolved
Renew all oil soaked lagging in way of # 1 SSDG to the satisfaction of the class society surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 18 March 2006
Resolution: Cleared by class
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 February 2006
Resolved
Magnetic compass not operating properly
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2006
Resolved 26 February 2006
Resolution: New compass installed by tech rep, report provided. Compass was not swung prior to departure. New 835 issued.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 February 2006
Resolved
Test operation of CO2 system time delay.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2006
Resolved 26 February 2006
Resolution: CO2 time delay operationally tested by ABS external specialist, servicing report provided attesting to the satisfactory operation.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 15 February 2006
Resolved
Require vessel to have an external Audit conducted to verify compliance with the vessel's current SMC.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2006
Resolved 26 February 2006
Resolution: ABS External audit conducted by ABS NY/NJ
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 15 February 2006
Resolved
Repair main engine aft thrust bearing seal to satifaction of ABS Class and the attending CG Marine Inspector prior to departing Portland, Maine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2006
Resolved 26 February 2006
Resolution: Main engine thrust bearing seal has temp repair by B and W tech rep. Approved by ABS surveyor and CG Inspector. Issued new 835 for permenant repairs NLT 12 March 06 to satisfaction of Class and CG and provide final report to this office.
Engineering › Fuel Oil Service System › Piping
Issued 15 February 2006
Resolved
Remove oil soaked insulation as identified by ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2006
Resolved 26 February 2006
Resolution: Private contractor removed oil soak insulation, verified by ABS surveyor and CG inspector. Flange tape installed on flanges.
Engineering › Generator (propulsion/auxiliary-electric) › Feeder Circuitry
Issued 15 February 2006
Resolved
Provide report attesting to the satisfactory operation of the #3 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2006
Resolved 26 February 2006
Resolution: Report provide by service tech attesting to sat operation of generator, verified by ABS surveyor and CG inspector.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 15 February 2006
Resolved
Provide tech report attesting to proper operation of ships boiler.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2006
Resolved 26 February 2006
Resolution: Boiler tech priovided service report attesting to sat operation, verified by ABS surveyor and CG inspector.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 15 February 2006
Resolved
Provide updated deviation table by independent surveyor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 18 March 2006
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 15 February 2006
Resolved
Make permanent repair to aft thrust bearing seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2006
Resolved 17 March 2006
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 13 February 2006
Resolved
IGS not performing up to standards, sensor problems and unknown problems. Class report requested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2006
Resolved 26 February 2006
Resolution: Service tech replaced IG flow transmitter, ABS surveyor and CG Inspector witnessed operational test.
Engineering › Bilge Water Management System › Pump
Issued 11 February 2006
Resolved
FOUND SLUDGE PUMP INOPERATIVE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: SHIPS FORCE REBUILT SLUDGE PUMP AND OPERATED, WITNESSED BY ABS SURVEYOR AND CG INSPECTOR
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 February 2006
Resolved
Lighing in emergency escape trunk from engine room is out.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: SHIPS CREW REPLACED LIGHT, VERIFIED BY CG INSPECTOR
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 February 2006
Resolved
Request ABS class report attesting to satisfactory operation of OWS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2006
Resolved 26 February 2006
Resolution: SHIPS CREW REPLACED CONTROLLER AND FREEDED UP 3 WAY VALVE, OPERATIONALLY TESTED AND VERIFIED BY ABS SURVEYOR AND CG INSPECTOR.
Electrical › Electric Generation Source (service) › Generator
Issued 11 February 2006
Resolved
No. 2 ship's generator not capable of carrying load.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: Service tech completed overhaul on #2 SSDG prime mover and verified by ABS surveyor and CG inspector.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 11 February 2006
Resolved
Request class report attesting to satisfactory operation of ships boiler feed pumps.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: Ships crew replaced boiler feed oil pumps and switch, verified operation by ABS Surveyor and CG inspector.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 11 February 2006
Resolved
Fresh water jacketwater leak on #1 MDE cylinder leaking.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: Ships crew and private contractor overhauled #1 cylinder on ships MDE. Verified by ABS surveyor and CG inspector.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 February 2006
Resolved
Piping has crack covered with temporary patch, piping needs to be replaced.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2006
Resolved 26 February 2006
Resolution: Ships crew and private shoreside contractor fabricated and installed approx 25-30 feet of 8 inch schedule 80 pipe. Verified installation and testing by ABS surveyor and CG inspector
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 February 2006
Resolved
Bigles covered in oily waste, needs to be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: Private contractor in Portland, Maine (Clean Harbors) cleaned and removed 24,198 gallons of bilge slops from vessel and disposed ashore. ABS surveyor and CG inspected bilges and verified cleaniness at this time.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 11 February 2006
Resolved
Incinerator needs class report attesting to satisfactory operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 26 February 2006
Resolution: Incinerator tech rep replaced new flame control box, new dosing pump stator and door locking solenoid valve. Provided servicing report and verified operational testing by tech rep, ABS surveyor and CG inspector.
Deck/Cargo › Cargo Stowage › General
Issued 12 September 2005
Resolved
When carrying benzene or benzene containing liquids, vessel must comply with all the requirements in 46 CFR 197 subpart C. Particularity crew personal protective equipment and regulated areas.
Due 12 October 2005
Resolved 29 September 2005
Resolution: Special note add to MISLE Critical Profile.
Communications › Radio Communications › EPIRB
Issued 12 September 2005
Resolved
Vessel is required to have an operational EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2005
Resolution: Provided EPIRB, FCC inspected and approved.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 September 2005
Resolved
Vessel must have a valid Certificate of Documentation prior to sailing or a copy pending receiving the original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2005
Resolution: Provided copy faxed from the Vessel Documentation Center.
Deck/Cargo › Cargo Stowage › General
Issued 12 September 2005
Resolved
Vessel is only authorized to carry cargos listed in MSC Letter (Serial C2-0505655) on domestic voyages pending Coast Guard approval of the P&A Manual.
Due 12 October 2005
Resolved 29 September 2005
Resolution: Special noted added to MISLE Critical Profile.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 12 September 2005
Resolved
Vessel must send copies of all Solas Certificates issued by ABS to MIO Europe either by email or fax.
Due 17 September 2005
Resolved 29 September 2005
Resolution: SOLAS Certificates information issued by ABS entered into Vessel Critical Profile.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 September 2005
Resolved
Modify CO2 system so that it is in compliance with US regulations 46 CFR 35.15-30. Prior to modifications, a plan must be submitted to this office and approved by the US Coast Guard.
Due 1 April 2006
Resolved 17 March 2006