Records from 2005 to 2014. Most recent: inspection, 23 October 2014.
Inspection history · 58
23 October 2014
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5010430
21 February 2012
Annual Inspection · MTSA/ISPS Verification · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4246641
29 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4098764
22 July 2011
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4090834
19 July 2011
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4090525
18 July 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4086763
18 July 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4089416
8 July 2011
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4077625
25 February 2011
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3952265
25 February 2011
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3955861
11 January 2011
Underwater Inspection in lieu of Drydock · Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Activities Europe · Activity 3900039
3 December 2010
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3903950
24 November 2010
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3898301
22 September 2010
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3855936
20 March 2010
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3704212
22 February 2010
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3684140
18 February 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3684201
2 December 2009
Special
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3646663
1 December 2009
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3642663
7 April 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3447976
25 March 2009
Type not recorded
No type recorded · Activities Europe · Activity 3440439
16 March 2009
Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3433007
16 March 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3447586
5 November 2008
Type not recorded
No type recorded · Activities Europe · Activity 3358766
1 November 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3357151
22 June 2008
Type not recorded
No type recorded · Activities Europe · Activity 3253191
3 June 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3242605
14 March 2008
Type not recorded
No type recorded · Activities Europe · Activity 3178832
23 January 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3134997
12 October 2007
ACP Annual Oversight · Administrative Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3078415
1 October 2007
Permit to Proceed
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3070645
28 September 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3068147
28 September 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3072258
20 July 2007
Type not recorded
No type recorded · Activities Europe · Activity 3153606
23 June 2007
Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2973179
21 June 2007
Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2969962
18 June 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2965779
1 May 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2919868
24 October 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2806886
4 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2735835
19 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2718435
17 July 2006
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2716309
12 July 2006
Deficiency Check
Physical examination · Activities Europe · Activity 2711182
26 June 2006
Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2692115
22 June 2006
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2688474
19 June 2006
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2685166
1 May 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2637881
27 April 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2637860
3 March 2006
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2595506
1 March 2006
Administrative Inspection
Administrative · Activities Europe · Activity 2610839
21 February 2006
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2587548
23 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539767
16 November 2005
Type not recorded
No type recorded · Activities Europe · Activity 2596583
24 October 2005
Type not recorded
No type recorded · Activities Europe · Activity 2596537
26 September 2005
Reflagging & Initial Certification
Administrative · Activities Europe · Activity 2495833
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501242
6 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2485378
6 September 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2485445
Fire Fighting › Fire Hoses › Length
Issued 24 September 2010
Resolved
Replace all 75 foot fire hoses with 50 foot fire hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 3 December 2010
Resolution: All 75 foot hoses replaced with 50 foot hoses.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 22 September 2010
Resolved
Renew sticking float for deck water seal low water level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 24 September 2010
Resolution: New float installed.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 22 September 2010
Resolved
Tighten loose PV valve on 6S cargo tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 23 September 2010
Resolution: Valve tightened.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 19 February 2010
Resolved
VSL's ODME readings were not correct and requires calibration and repairs.
Action required: 705 - Other - as specified
Due 17 April 2010
Resolved 20 March 2010
Resolution: ODME has been repaired and tested satisfactorily.
Engineering › Steering Gear System › Power Unit
Issued 2 December 2009
Resolved
Port side hydraulic tank for the pump is leaking hydraulic fluid at the gasket.
Action required: 705 - Other - as specified
Due 4 December 2009
Resolved 3 December 2009
Resolution: Gasket was replaced and leaking has stopped.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 December 2009
Resolved
Visual indicator for alarm in steering gear room is inoperable.
Action required: 705 - Other - as specified
Due 4 December 2009
Resolved 3 December 2009
Resolution: Visual alarm in steering gear room is now operable.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 December 2009
Resolved
Provide adjustment to D deck fire door in main stair tower so that it is self closing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2009
Resolved 2 December 2009
Resolution: Proved door is capable of self closure.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 December 2009
Resolved
Remove plastic dryer duct and replace with metallic duct.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2009
Resolved 2 December 2009
Resolution: Metallic duct installed.
Fire Fighting › Fire Hoses › Condition
Issued 2 December 2009
Resolved
Remove failed fire hoses and replace.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2009
Resolved 3 December 2009
Resolution: Provided 12 new hoses.
Deck/Cargo › Crude Oil Washing Systems › Stripping System Piping
Issued 12 October 2007
Resolved
Cargo Tanks number one and number 8 do not meet new MARPOL standards, stripping rates show over 200 liters from each tank. Vessel is prohibited from carrying NLS cargoes in these tanks until modifications can be made and the 2007 MARPOL requirements are met. Vessel must continue to follow stability and loading plans. It is expected that the modifications will be made at the next drydock in 2008.
Action required: 705 - Other - as specified
Resolved 2 March 2008
Resolution: Stripping test was performed successfully on cargo tanks #1 & #8.
Engineering › Steering Gear System › Rudder
Issued 1 October 2007
Resolved
Vessel cannot control steering from the bridge when operating with the STBD pump.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 October 2007
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 23 June 2007
Resolved
Repair and demonstrate proper operation of propulsion engine prior to departure from Port Canaveral, FL.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2007
Resolved 24 June 2007
Resolution: Completed.
Engineering › Steering Gear System › Pump
Issued 21 June 2007
Resolved
Repair and demonstrate proper operation of port steering gear prior to departure from Port Canaveral, FL.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2007
Resolved 22 June 2007
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 17 July 2006
Resolved
Was not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2006
Resolution: Tech report received and unit operates correctly.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 July 2006
Resolved
Was not operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2006
Resolution: Repairs complete and unit operating correctly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 July 2006
Resolved
Frame Cargo Pump #6P was not working properly.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2006
Resolution: Tech report received that unit has been repaired and operating correctly.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 19 June 2006
Resolved
No tagout log system/procedures in place
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Engineering › Steering Gear System › Power Unit
Issued 19 June 2006
Resolved
Repair Junction box wires in steering gear room
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2006
Resolved 26 June 2006
Engineering › Steam System (main) › Piping
Issued 19 June 2006
Resolved
Renew saltwater cooling piping on steam drain holding tank
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 June 2006
Resolved
Provide a tech servicing report for oily water seperators proper operation
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2006
Resolution: Repaired and operating properly.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 19 June 2006
Resolved
Provide a tech servicing report for proper operation of the vessels incinerator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2006
Engineering › Fuel Oil Service System › Pump
Issued 19 June 2006
Resolved
Repair junction box on boiler fuel pumps in the purifier room
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 19 June 2006
Resolved
Replace cover on fire alarm activation point in Aft steering
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Engineering › Diesel Engine (auxiliary) › Block
Issued 19 June 2006
Resolved
Fix fuel leak on #3 generater duplex fitters
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 21 February 2006
Resolved
Repair the following tank level transmitting devices:
#3 Port High Level Alarm
#3 Port Overflow Alarm
#6 Port Overflow Alarm
Action required: 15 - Rectify deficiencies by next port
Due 21 April 2006
Resolved 24 February 2006
Lifesaving › Rescue Boat › Construction
Issued 14 December 2005
Resolved
Replace the rescue boat (ZODIAC RIBO 420) on board the vessel with a Coast Guard approved rescue boat. Existing rescue boat, at the time of the re-flag, was replaced on 28Nov05. Need to verify if launching appliance meets new rescue boat installation. See narrative for activity #2495833.
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 12 July 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 September 2005
Resolved
Install a high pressure CO2 system that conforms to 46 CFR 95.15-30.
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 21 February 2006
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 26 September 2005
Resolved
Remove all NLS cargoes from the P&A Manual that do not appear in 46 CFR 151.47 and 151.49.
Due 8 November 2005
Resolved 8 November 2005
Resolution: Removed as an CG-835 item and added to Special Notes.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 26 September 2005
Resolved
Submit three copies of the updated/amended P&A Manual to the MSC for approval.
Due 8 November 2005
Resolved 8 November 2005
Resolution: Removed as an CG-835 item and added to Special Notes.
Documentation › Safety Management System › Response Measures Documentation
Issued 26 September 2005
Resolved
Complete DNV recommendations by specified dates (submit intact stability declaration and SOPEP to MSC or RO for review and approval, repair the inoperable #4 starboard high level alarm, repair boiler high temperature alarm at the control panel) and provide written report describing corrective actions.
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 21 February 2006