MAURY USCG vessel records Sign in
← All vessels

OVERSEAS LUXMAR

OVERSEAS LUXMAR is a 1998 tank ship. The Coast Guard has recorded 58 inspections since 2005, most recently in October 2014, along with 30 deficiencies, 3 operational controls and 18 casualty investigations between 2005 and 2012.

Records from 2005 to 2014. Most recent: inspection, 23 October 2014.

Built
1998
Last inspected
23 October 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9129940 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC7070
782253
Flag
MARSHALL ISLANDS
303478000 (licence lapsed)
Maury page id
psix-782253

Inspections, by type

…with no type recorded25
Years with a record 9 calendar years (2005–2014)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28357 - Convention (Subpart B), Gross Ton
12549 - Convention (Subpart B), Net Ton
39999 - Dead Weight, Ton
49695 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7070MMSI 303478000 · expired · compulsorily equipped · granted 7 September 2005, cancelled 7 November 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AVA FAITH Towing Vessel · MISLE 92904 · 1 November 2008 · activity 3357151

Inspection history · 58

23 October 2014 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5010430
21 February 2012 Annual Inspection · MTSA/ISPS Verification · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4246641
29 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4098764
22 July 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4090834
19 July 2011 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4090525
18 July 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4086763
18 July 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4089416
8 July 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4077625
25 February 2011 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3952265
25 February 2011 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3955861
11 January 2011 Underwater Inspection in lieu of Drydock · Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Activities Europe · Activity 3900039
3 December 2010 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3903950
24 November 2010 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3898301
22 September 2010 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3855936
20 March 2010 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3704212
22 February 2010 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3684140
18 February 2010 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3684201
2 December 2009 Special
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3646663
1 December 2009 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3642663
7 April 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3447976
25 March 2009 Type not recorded
No type recorded · Activities Europe · Activity 3440439
16 March 2009 Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3433007
16 March 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3447586
5 November 2008 Type not recorded
No type recorded · Activities Europe · Activity 3358766
1 November 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3357151
22 June 2008 Type not recorded
No type recorded · Activities Europe · Activity 3253191
3 June 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3242605
14 March 2008 Type not recorded
No type recorded · Activities Europe · Activity 3178832
23 January 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3134997
12 October 2007 ACP Annual Oversight · Administrative Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3078415
1 October 2007 Permit to Proceed
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3070645
28 September 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3068147
28 September 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3072258
20 July 2007 Type not recorded
No type recorded · Activities Europe · Activity 3153606
23 June 2007 Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2973179
21 June 2007 Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2969962
18 June 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2965779
1 May 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2919868
24 October 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2806886
4 August 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2735835
19 July 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2718435
17 July 2006 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2716309
12 July 2006 Deficiency Check
Physical examination · Activities Europe · Activity 2711182
26 June 2006 Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2692115
22 June 2006 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2688474
19 June 2006 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2685166
1 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2637881
27 April 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2637860
3 March 2006 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2595506
1 March 2006 Administrative Inspection
Administrative · Activities Europe · Activity 2610839
21 February 2006 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2587548
23 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539767
16 November 2005 Type not recorded
No type recorded · Activities Europe · Activity 2596583
24 October 2005 Type not recorded
No type recorded · Activities Europe · Activity 2596537
26 September 2005 Reflagging & Initial Certification
Administrative · Activities Europe · Activity 2495833
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501242
6 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2485378
6 September 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2485445

Deficiency record · 30

Fire Fighting › Fire Hoses › Length
Issued 24 September 2010 Resolved
Replace all 75 foot fire hoses with 50 foot fire hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 3 December 2010
Resolution: All 75 foot hoses replaced with 50 foot hoses.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 22 September 2010 Resolved
Renew sticking float for deck water seal low water level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 24 September 2010
Resolution: New float installed.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 22 September 2010 Resolved
Tighten loose PV valve on 6S cargo tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2010
Resolved 23 September 2010
Resolution: Valve tightened.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 19 February 2010 Resolved
VSL's ODME readings were not correct and requires calibration and repairs.
Action required: 705 - Other - as specified
Due 17 April 2010
Resolved 20 March 2010
Resolution: ODME has been repaired and tested satisfactorily.
Engineering › Steering Gear System › Power Unit
Issued 2 December 2009 Resolved
Port side hydraulic tank for the pump is leaking hydraulic fluid at the gasket.
Action required: 705 - Other - as specified
Due 4 December 2009
Resolved 3 December 2009
Resolution: Gasket was replaced and leaking has stopped.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 December 2009 Resolved
Visual indicator for alarm in steering gear room is inoperable.
Action required: 705 - Other - as specified
Due 4 December 2009
Resolved 3 December 2009
Resolution: Visual alarm in steering gear room is now operable.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 December 2009 Resolved
Provide adjustment to D deck fire door in main stair tower so that it is self closing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2009
Resolved 2 December 2009
Resolution: Proved door is capable of self closure.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 December 2009 Resolved
Remove plastic dryer duct and replace with metallic duct.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2009
Resolved 2 December 2009
Resolution: Metallic duct installed.
Fire Fighting › Fire Hoses › Condition
Issued 2 December 2009 Resolved
Remove failed fire hoses and replace.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2009
Resolved 3 December 2009
Resolution: Provided 12 new hoses.
Deck/Cargo › Crude Oil Washing Systems › Stripping System Piping
Issued 12 October 2007 Resolved
Cargo Tanks number one and number 8 do not meet new MARPOL standards, stripping rates show over 200 liters from each tank. Vessel is prohibited from carrying NLS cargoes in these tanks until modifications can be made and the 2007 MARPOL requirements are met. Vessel must continue to follow stability and loading plans. It is expected that the modifications will be made at the next drydock in 2008.
Action required: 705 - Other - as specified
Resolved 2 March 2008
Resolution: Stripping test was performed successfully on cargo tanks #1 & #8.
Engineering › Steering Gear System › Rudder
Issued 1 October 2007 Resolved
Vessel cannot control steering from the bridge when operating with the STBD pump.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 October 2007
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 23 June 2007 Resolved
Repair and demonstrate proper operation of propulsion engine prior to departure from Port Canaveral, FL.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2007
Resolved 24 June 2007
Resolution: Completed.
Engineering › Steering Gear System › Pump
Issued 21 June 2007 Resolved
Repair and demonstrate proper operation of port steering gear prior to departure from Port Canaveral, FL.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2007
Resolved 22 June 2007
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 17 July 2006 Resolved
Was not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2006
Resolution: Tech report received and unit operates correctly.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 July 2006 Resolved
Was not operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2006
Resolution: Repairs complete and unit operating correctly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 17 July 2006 Resolved
Frame Cargo Pump #6P was not working properly.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2006
Resolution: Tech report received that unit has been repaired and operating correctly.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 19 June 2006 Resolved
No tagout log system/procedures in place
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Engineering › Steering Gear System › Power Unit
Issued 19 June 2006 Resolved
Repair Junction box wires in steering gear room
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2006
Resolved 26 June 2006
Engineering › Steam System (main) › Piping
Issued 19 June 2006 Resolved
Renew saltwater cooling piping on steam drain holding tank
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 June 2006 Resolved
Provide a tech servicing report for oily water seperators proper operation
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2006
Resolution: Repaired and operating properly.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 19 June 2006 Resolved
Provide a tech servicing report for proper operation of the vessels incinerator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2006
Engineering › Fuel Oil Service System › Pump
Issued 19 June 2006 Resolved
Repair junction box on boiler fuel pumps in the purifier room
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 19 June 2006 Resolved
Replace cover on fire alarm activation point in Aft steering
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Engineering › Diesel Engine (auxiliary) › Block
Issued 19 June 2006 Resolved
Fix fuel leak on #3 generater duplex fitters
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2006
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 21 February 2006 Resolved
Repair the following tank level transmitting devices: #3 Port High Level Alarm #3 Port Overflow Alarm #6 Port Overflow Alarm
Action required: 15 - Rectify deficiencies by next port
Due 21 April 2006
Resolved 24 February 2006
Lifesaving › Rescue Boat › Construction
Issued 14 December 2005 Resolved
Replace the rescue boat (ZODIAC RIBO 420) on board the vessel with a Coast Guard approved rescue boat. Existing rescue boat, at the time of the re-flag, was replaced on 28Nov05. Need to verify if launching appliance meets new rescue boat installation. See narrative for activity #2495833.
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 12 July 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 September 2005 Resolved
Install a high pressure CO2 system that conforms to 46 CFR 95.15-30.
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 21 February 2006
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 26 September 2005 Resolved
Remove all NLS cargoes from the P&A Manual that do not appear in 46 CFR 151.47 and 151.49.
Due 8 November 2005
Resolved 8 November 2005
Resolution: Removed as an CG-835 item and added to Special Notes.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 26 September 2005 Resolved
Submit three copies of the updated/amended P&A Manual to the MSC for approval.
Due 8 November 2005
Resolved 8 November 2005
Resolution: Removed as an CG-835 item and added to Special Notes.
Documentation › Safety Management System › Response Measures Documentation
Issued 26 September 2005 Resolved
Complete DNV recommendations by specified dates (submit intact stability declaration and SOPEP to MSC or RO for review and approval, repair the inoperable #4 starboard high level alarm, repair boiler high temperature alarm at the control panel) and provide written report describing corrective actions.
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 21 February 2006

Casualty record · 18

24 October 2005Routine · role: Involved in a Marine Casualty · activity 2596537
16 November 2005Routine · role: Involved in a Marine Casualty · activity 2596583
4 August 2006Routine · role: Involved in a Marine Casualty · activity 2735835
20 July 2007Routine · role: Involved in a Marine Casualty · activity 3153606
28 September 2007Routine · role: Involved in a Marine Casualty · activity 3072258
14 March 2008Routine · role: Involved in a Marine Casualty · activity 3178832
22 June 2008Routine · role: Involved in a Marine Casualty · activity 3253191
1 November 2008Routine · role: Involved in a Marine Casualty · activity 3357151
5 November 2008Routine · role: Involved in a Marine Casualty · activity 3358766
25 March 2009Routine · role: Subject to Marine Inspection · activity 3440439
19 August 2009Routine · role: Involved in a Marine Casualty · activity 3590862
18 February 2010Routine · role: Involved in a Marine Casualty · activity 3684201
24 April 2010Routine · role: Involved in a Marine Casualty · activity 3764036
1 August 2010Routine · role: Involved in a Marine Casualty · activity 3820106
9 August 2010Routine · role: Involved in a Marine Casualty · activity 3821779
25 February 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3955861
18 July 2011Routine · role: Involved in a Marine Casualty · activity 4086763
29 March 2012Routine · role: Involved in a Marine Casualty · activity 4276728
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.