MAURY USCG vessel records Sign in
← All vessels

WAN HAI 622

WAN HAI 622 is a 2005 freight ship. The Coast Guard has recorded 32 inspections since 2005, most recently in April 2024, along with 12 deficiencies and 1 operational control.

Records from 2005 to 2024. Most recent: inspection, 15 April 2024.

Built
2005
Last inspected
15 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9307035 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V7053
783671
Flag
MARSHALL ISLANDS
—
Maury page id
psix-783671

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (2005–2024)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it71837 - Convention (Subpart B), Gross Ton
29112 - Convention (Subpart B), Net Ton
99620 - Displacement, Ton
72968 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

15 April 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7895266
14 October 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7068967
25 January 2020 Deficiency Check · Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6895935
30 October 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6845187
23 August 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6792310
16 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6785466
17 August 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6511498
16 August 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6238238
9 April 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5842844
7 October 2014 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5000203
26 February 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4251774
22 August 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4123539
15 February 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3945756
11 October 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3867713
4 May 2008 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3198671
2 April 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3176142
19 October 2007 ISPS II Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3081173
19 September 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3061448
16 September 2007 Random ISPS/MTSA-No PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3058685
6 June 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2953633
14 May 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2930496
27 April 2007 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2916925
19 January 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2858772
17 January 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2857584
30 September 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2790637
3 September 2006 PII Safety Exam · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2767250
4 August 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2736036
7 May 2006 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2642706
4 September 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2483326
28 August 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2477357
27 August 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2476756
22 August 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2471607

Deficiency record · 12

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 October 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. While lowering the port side lifeboat one davit arm lowerd before the other causing the lifeboat to cant and lower unevenly in an unsafe manner.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2019
Resolved 30 October 2019
Resolution: Received class report.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 30 October 2019 Resolved
Oil filtering equipment referred to in paragraph 2 of this regulatoin shall comply with paragraph 6 of this regulation. It was observed on 16SEP19 the vessel discharged 41.62 cubic meters of bilge water through the OWS in 8 hours (0900-1700) exceeding the max through put (5 cubic meters/hour). While examining the OWS the chief engineer could not show the recirculating function. After priming the system and opening the recirculation valve the system over pressurized, breaking multiple gaskets and a pressure gauge on the system. System was not tested satisfactorily for the PSCO
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2019
Resolved 30 October 2019
Resolution: Received class report
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. Newly installed laundry machines were hooked up to several wires spliced together leading to a transformer. Wire were located in crew laundry room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 January 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 October 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the persons on board. A bucket catching leaking oil was observed at the shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 25 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 October 2019 Resolved
The liferaft shall be marked with maker's name, serial number, date of manufacture, name of approving authority, name and place of servicing station. All inflatable liferaft labels were missing some/all required information.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2019
Resolved 4 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 October 2019 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and selfclosing. The A/C room on the upper deck and the galley A/C room on A deck, which by definition in SOLAS are machinery spaces of Category A. Neither door is fitted on an "A-0" and "A-60" door in sterring gear room. Finally another A-0 door to steering gear was unable to close properly via the self closing device.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 25 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the proisions of the present regulations to ensure ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The port side bunker manifold is missing 2 bolts at the flange leading to the reducer.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 October 2019
Resolved 4 November 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 30 October 2019 Resolved
The company should ensure that the safety management system operating on board the ship contains clear statement emphasizing the master's authority. The company should establish in the safety management system that the master has the overriding authority and the responsibliity to make decisions with respect to safety and pollution prevention and to request the company's assistance as may be necessary. While lowering the port side lifeboat the crew did not install the required fall prevention device. Additionally the fire fighters left their required radios in the fire locker and did not bring them to the drill. Additionally, it was observed the vessel procured new washing machines last summer. The new washers are 110V and the ship supplies 220V. The crew spliced multiple lines to wire the machines without approval from class. During the engine room exam the PSCO observed a makeshift catch (bucket) underneath the stern tube filled with oil. The cief engineer could not explain why it was there and the company has no established procedures for logging soundings of the sterntube tank. During the test of local steering the crew was unaware of the presence of the rudder angle indicator.Rather, a crew member climbed on top of the steering gear to observe the rudder indicator on top of the rudder stock. Recommend an ISM audit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 25 January 2020
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 August 2011 Resolved
Vessel is required to have proper test equipment to test smoke and heat detectors. Vessel had no proper means to test the fixed fire detection system. Vessel is required to provide proof of receipt of proper maintenance equipment to the Coast Guard. SOLAS II-2 Reg 7.3.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 September 2011
Resolution: Vessel provided to Sector NY a copy of the delivery order for "Smoke Detector Tester" and "Heat Detector Tester". Maintenance equipment is know on board for proper testing of fire protection system.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 September 2007 Resolved
SSO COULD NOT PROVIDE PSCO WITH A CURRENT RECORD OF DRILLS. DRILL RECORD INDICATES THAT SECURITY DRILLS HAVE NOT BEEN RECORDED AS CONDUCTED SINCE 30 MAY 2007. ISPS CODE PART A, 13.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2007
Resolution: USCG REVIEWED AND VERIFIED SHIPS SECURITY DRILLS ENTERED INTO THE SHIPS BRIDGE LOG BOOK.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 September 2007 Resolved
Bosun stores port and starboard access hatches were locked on the outside preventing crew access to forward life raft embarkations and means of escape. To be rectified at next U.S. port after sailing foreign to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 19 October 2007
Resolution: USCG INSPECTED PORT AND STARBOARD ACCESS HATCHES TO BOSUN STORES INSTALLED W/ DETACHABLE BOLT WINGNUTS ALLOWING HATCHES TO BE ACCESABLE FROM WITHIN THE INSIDE IN CASE OF EMERGENCY.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 September 2006 Resolved
Fire doors in galley boundaries are not self-closing class A0 doors. SOLAS Consolidated Edition 2004 Chapter II-2 Part C, Regulation 9 4.1.1.4.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2006
Resolution: Inspected fire doors in galley and all A0 doors located in the space are now self closing.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.