MAURY USCG vessel records Sign in
← All vessels

APOLLON

APOLLON is a 2005 tank ship. The Coast Guard has recorded 22 inspections since 2005, most recently in March 2022, along with 2 deficiencies and 6 operational controls.

Records from 2005 to 2022. Most recent: inspection, 29 March 2022.

Built
2005
Last inspected
29 March 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9289532 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
786712
Flag
BAHAMAS, THE
—
Maury page id
psix-786712

Inspections, by type

…with no type recorded8
Years with a record 13 calendar years (2005–2022)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it49999 - Dead Weight, Metric Ton
60365 - Displacement, Metric Ton
30053 - Convention (Subpart B), Gross Ton
14378 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

29 March 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7419716
13 March 2021 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7155438
28 March 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6931037
15 November 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6579261
22 November 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6339149
21 November 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6309137
7 November 2016 COC-CHEM & TVE Annual · COE-Dockside · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6035070
23 November 2015 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5768793
15 January 2012 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4222175
9 January 2012 PII Safety Exam · COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4221195
12 October 2010 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3868073
9 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3866574
5 September 2008 COC-CHEM Renew · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3307532
28 June 2007 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2976601
5 July 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2703015
28 June 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2694689
23 June 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2689721
14 May 2006 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2646801
10 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2583361
19 October 2005 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2517428
4 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2508080
4 September 2005 ISPS II Exam · MARPOL Annex V Examination · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2483032

Deficiency record · 2

Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 21 November 2017 Resolved
Chemical tankers which have been surveyed and certified with the provisions of the International Bulk Chemical Code as applicable shall be deemed to have complied with the provisions of the said regulation. The conditions of the ship and its equipment shall be maintained to conform with the provisions of the code will remain fit to proceed to sea without danger to the ship or persons on board or the environment. PSCO noted that the gas regulating valve for the inert gas system is not able to open and close automatically. Marpol II/7 & IBC Code (16) 1.5.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2017
Resolution: Class report provided
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 9 January 2012 Resolved
During inspection of the ships inert gas system, the inert gas generator failed to operate. The inert gas system shall be capable of inerting the atmosphere in cargo tanks, the cargo tanks are currently inert, however the ship cannot discharge cargo and maintain its current atmosphere. Prior to cargo operations the vessel's class society is to attend the vessel and witness satisfactory operation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2012
Resolved 16 January 2012
Resolution: Received class report from Llyods attesting to the safe operation of the IG Generator. Def is now cleared and vessel was allowed to do cargo.

Ownership record