MAURY USCG vessel records
← All vessels

MISS BODIE ISLAND

MISS BODIE ISLAND is a 2006 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in October 2025, along with 6 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 14 October 2025.

Built
2006
Last inspected
14 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 October 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5018
786730
Flag
UNITED STATES
Maury page id
psix-786730

Documentation record

Tonnage as PSIX records it7 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

14 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8251465
9 September 2025 COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8213126
5 September 2024 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8003448
3 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7819378
27 September 2023 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7795809
21 September 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7562766
29 November 2021 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7356290
15 October 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7331927
14 September 2020 COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7054058
21 November 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6860318
20 September 2019 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6816719
29 October 2018 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6570207
19 September 2018 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6544168
16 November 2017 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6303939
10 October 2017 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6284492
26 September 2017 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6275099
16 September 2016 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6001367

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2021 Resolved
Ensure all passenger seats are properly secured to vessel. Seats are not secure and missing hardware. Repair in accordance with 46CFR176.802.(a). Due by end of next vessel dry dock.
Action required: 705 - Other - as specified
Resolved 6 December 2021
Resolution: Seats through bolted no loose seats were found on board.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 15 October 2021 Resolved
Ensure drills are logged IAW 46CFR185.420. Drills need to be conducted once every three months. (46CFR185.520,524)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: Instructed master to log drills at proper intervals. Master logged drills while MI onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 October 2021 Resolved
Port and Starboard navigation lights are inoperable. Ensure lights are functioning properly in accordance with 46CFR183.420.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 19 November 2021
Resolution: All Navigation lights operational via video.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 September 2018 Resolved
Comply with the applicable installation certificates issued by the FCC. FCC Safety Certificate was found expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 22 November 2018
Resolution: Received a copy of the vessel's new FCC Safety Radiotelephony Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2018 Resolved
Materials used in piping systems must meet the requirements of 46CFR182.720 and be acceptable to the cognizant [name withheld] side fuel tank vent line was found cracked and unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2018
Resolved 29 October 2018
Resolution: Inspected installation of new fuel line; all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 September 2017 Resolved
Found several items in the medical kit expired. Procure new items.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 10 October 2017
Resolution: O/O procured the required items.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.