Records from 2006 to 2025. Most recent: inspection, 14 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
14 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8251465
9 September 2025
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8213126
5 September 2024
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8003448
3 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7819378
27 September 2023
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7795809
21 September 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7562766
29 November 2021
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7356290
15 October 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7331927
14 September 2020
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7054058
21 November 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6860318
20 September 2019
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6816719
29 October 2018
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6570207
19 September 2018
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6544168
16 November 2017
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6303939
10 October 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6284492
26 September 2017
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6275099
16 September 2016
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6001367
20 October 2015
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5746376
17 September 2015
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5238454
27 September 2011
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4155560
1 May 2008
Annual Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3196285
12 September 2007
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3056059
5 March 2007
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2871028
11 April 2006
Initial Certification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2621789
24 February 2006
Deadweight Survey · Construction Oversight
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2591542
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2021
Resolved
Ensure all passenger seats are properly secured to vessel. Seats are not secure and missing hardware. Repair in accordance with 46CFR176.802.(a). Due by end of next vessel dry dock.
Action required: 705 - Other - as specified
Resolved 6 December 2021
Resolution: Seats through bolted no loose seats were found on board.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 15 October 2021
Resolved
Ensure drills are logged IAW 46CFR185.420. Drills need to be conducted once every three months. (46CFR185.520,524)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2021
Resolution: Instructed master to log drills at proper intervals. Master logged drills while MI onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 October 2021
Resolved
Port and Starboard navigation lights are inoperable. Ensure lights are functioning properly in accordance with 46CFR183.420.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 19 November 2021
Resolution: All Navigation lights operational via video.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 September 2018
Resolved
Comply with the applicable installation certificates issued by the FCC. FCC Safety Certificate was found expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 22 November 2018
Resolution: Received a copy of the vessel's new FCC Safety Radiotelephony Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2018
Resolved
Materials used in piping systems must meet the requirements of 46CFR182.720 and be acceptable to the cognizant [name withheld] side fuel tank vent line was found cracked and unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2018
Resolved 29 October 2018
Resolution: Inspected installation of new fuel line; all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 September 2017
Resolved
Found several items in the medical kit expired. Procure new items.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 10 October 2017
Resolution: O/O procured the required items.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 17 September 2015
Resolved
Provide onboard waterproof container for distress signals. Vessel did not have a portable waterproof container for distress signals onboard. 46 CFR 180.68 & 46 CFR 185.614
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Verified watertight container for distress markers.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 September 2015
Resolved
Replace four wing nuts on batteries with permanent type connectors (hex nuts). 46 CFR 183.350(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Wing nuts were replaced with permanent type connectors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 September 2015
Resolved
Replace bow lifelight battery (expired) and stern lifelight batteries (not operational) on ring life buoys. 46 CFR 180.70(d), Vessel is restricted to daylight operations only until deficiency is corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Both life buoy light batteries were replaced and both tested satisfactory.
Engineering › Fuel Oil Service System › Hose
Issued 17 September 2015
Resolved
Replace fuel fill flexible hose on STBD and Port side fuel tanks. Hoses were both found to be rotted. 46 CFR 182.720(e)(3)(V)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Fuel fill flexible hoses for port/stbd tanks were replaced with proper type hoses for service.
Engineering › Fuel Oil Service System › Piping
Issued 17 September 2015
Resolved
Replace bonding strap on Port and STBD side of the fuel tank fills. Bonding strap found to be extremely corroded. 46 CFR 182. 445(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Bonding straps were replaced as required on port/stbd fuel tanks.
Engineering › Fuel Oil Service System › Hose
Issued 17 September 2015
Resolved
Replace approximately 6 " of fuel supply hose on STBD side near primer bulb and before oil/water seperator. Hose found to be cracked and rotted. 46 CFR 182.720(e)(3)(v)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Replaced fuel hose above primer bulb on stbd side as required.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 17 September 2015
Resolved
Provide onboard DOT approved alcohol test strips for serious marine incident testing (one for each crew member). 46 CFR 185.212
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: DOT approved alcohol test strips were on board as required.
Documentation › Markings/Placards › Certificate of Number (state)
Issued 11 April 2006
Resolved
Mark vessel with state registration numbers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 April 2006
Resolved
Post emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Lifesaving › Lifebuoys › Not on Board
Issued 11 April 2006
Resolved
Provide additional orange 24" ring buoy with lifeline and waterlight for reduced manning operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2006
Resolved
Repair VHF radio and test in the presence of the attending marine inspector. Vessel operations are restricted to within 1000' from shore until repaired.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2006
Resolved
Mark navigation light switches IWO operating station.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 11 May 2006
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 11 April 2006
Resolved
Repair GPS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 11 May 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 April 2006
Resolved
Repair radar cable (damaged in-transit to NC.)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 11 May 2006
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 11 April 2006
Resolved
Post lifejacket donning placards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Operations/Management › Pollution › Control of Garbage
Issued 11 April 2006
Resolved
Post MARPOL V placard.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 11 May 2006
Construction/Loadline › Hull › Transverse Frame
Issued 11 April 2006
Resolved
Provide documentation of sat CG witnessed torsion test or submit torsion calculations to the MSC for review to verify hull cross structure connections/tie-ins & suitability for ops on PPW's.
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 20 March 2007
Resolution: Witnessed by MSD Fort Meyers on a similar vsl.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 24 February 2006
Resolved
PROVIDE A CURRENT FCC STATION LICENSE AND A FCC SAFETY RADIO TELEPHONY CERTIFICATE FOR THE VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 February 2006
Resolved
PROVIDE A VALID STATE REGISTRATION FOR VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006
Resolution: Registered.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 February 2006
Resolved
PROVIDE DOCUMENTATION OF PROOF OF ENROLLMENT IN A DRUG AND ALCOHOL TESTING PROGRAM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006
Resolution: Verified DAPI compliance.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 February 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 February 2006
Resolved
PROVIDE A TRAINING LOGBOOK ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 24 February 2006
Resolved
PROVIDE A PASSENGER COUNT LOCATION ASHORE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006
Resolution: Provided
Navigation › Piloting/Steering › Marine Charts
Issued 24 February 2006
Resolved
PROVIDE ALL REQUIRED NAVIGATION PUBLICATIONS ONBOARD; CHARTS, TIDE TABLES, ETC..
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Communications › Radio Communications › EPIRB
Issued 24 February 2006
Resolved
PROVIDE NOAA REGISTRATION FOR THE 406mhz EPIRB AND MARK SAME WITH VESSELS NAME.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 February 2006
Resolved
DEMONSTRATE A PROPER PASSENGER SAFETY ORIENTATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006
Resolution: Demonstrated.
Lifesaving › Lifefloat › Not on Board
Issued 24 February 2006
Resolved
PROPERLY STOW THE LIFEFLOATS IN THE REQUIRED FLOAT-FREE ARRANGEMENT WITH THE REQUIRED AMOUNT OF PADDLES, LIGHTS, PAINTER/WEAKLINK AND MARKINGS.
Action required: 705 - Other - as specified
Resolved 11 May 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 February 2006
Resolved
CONDUCT EMERGENCY DRILLS UNDERWAY TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006
Resolution: Witnessed.