CHAMPION EBONY

CHAMPION EBONY is a 2004 tank ship. The Coast Guard has recorded 10 inspections since 2016, most recently in August 2025, along with 8 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 20 August 2025.

Built
2004
Last inspected
20 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9290608
786758
Flag
NORWAY
Maury page id
psix-786758

Documentation record

Tonnage as PSIX records it46938 - Dead Weight, Metric Ton
60793 - Displacement, Metric Ton
27547 - Convention (Subpart B), Gross Ton
13855 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

20 August 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8203192
22 August 2022 COC-CHEM Renew · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7540305
21 March 2021 COC-CHEM & TVE Annual · PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7158497
19 November 2019 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6858303
2 October 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6553359
22 August 2018 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6502713
7 August 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6503812
8 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6201905
25 June 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6178047
24 June 2016 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5934456

Deficiency record · 8

09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 22 August 2018 Resolved
1870 - Tanker - Special requirements - Ships carrying toxic or flammable products or both shall be equipped with at least two instruments designed and calibrated for testing for the specific vapours in question. Both of the vessels' four gas analyzers have bad H2S sensors. The vessel does have current to date H2S Drager tubes if testing was required. - 74 SOLAS (14) VII / 10 - IBC 13.2.1 - 16 a or c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 2 October 2018
Resolution: Class report provided.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2018 Resolved
0750 - Fire fighting / Fire prevention - Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold-back arrangements fitted with remote release devices of the fail-safe type may be utilized. The class A door going from the passageway into the galley had a hold-back installed to allow for the door to be blocked open. - 74 SOLAS (14) 11-2/9.4.2.2 - 10c
Action required: 10 - Deficiency Rectified
Due 22 August 2018
Resolved 22 August 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 August 2018 Resolved
0680 - Embarkation arrangement survival craft - Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/43. Vessel's emergency lighting on port bridge wing was found inoperable. - SOLAS 74 (14 CONS) III/11.4 - 10c
Action required: 10 - Deficiency Rectified
Due 22 August 2018
Resolved 22 August 2018
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 August 2018 Resolved
0750 - Fire prevention - structural fire protection including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed a hole in the bulkhead of the provision store room adjacent to the Suez crew room. Bulkhead is considered to be a class A boundary in accordance with vessel's fire control plan. The hole in bulkhead is approximately 2 inches in size, on upper corner in provision store room. - SOLAS 74 (14 CONS) II-2/14.2.1.1 - 16 a or c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 17 September 2018
Resolution: Class report attesting to the correction of the bulkhead in the Class A boundary's repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 August 2018 Resolved
1870 - Tankers - special requirements - In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed, and maintained in compliance with structural, mechanical and electrical requirements of a classification society which is recognized by the administration. On the cargo deck the Inert Gas System supply lines has electrical bonding straps at all the pipe flanges numerous bonding straps are broken and one pipe connection has a bolt that is missing the head of the bolt. - 74 SOLAS (04) 11-1/3-1 - 10c
Action required: 10 - Deficiency Rectified
Due 22 August 2018
Resolved 22 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2018 Resolved
1499 - Propulsion and auxiliary machinery - other - Exposed metal parts of electrical machinery or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. MGO fuel oil pump (composite ignition pump for boiler) located at MGO tank by IGG had a broken bonding ground on the pump. Strap was loose and required re-connection. - 74 SOLAS (04) 11-1/45.1.1 - 10c
Action required: 10 - Deficiency Rectified
Due 22 August 2018
Resolved 22 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 August 2018 Resolved
0715 - Detection - Suitable instructions and component spares for testing and maintenance shall be provided. Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. PSCO observed flame detectors in purifior room not operational. Flame detector lamp was not charged for proper operation. - 74 SOLAS (14 CONS) II-2/7.2.2.2 - F.S.S COD CH.9.2.5.2 - 16 a or c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 2 October 2018
Resolution: Class report provided.
Construction/Loadline › Markings › Load Line Mark
Issued 25 June 2017 Resolved
1220 - The lines which indicate the load line assigned in accordance with these regulations shall be horizontal lines 230 mm in length and 25 mm in breadth which extend forward of, unless expressly provided otherwise, and at right angles to, a vertical line 25 mm in breadth marked at a distance 540 mm forward of the center of the ring. ICLL Annex I/CH.I Reg.6
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 July 2017
Resolved 8 July 2017
Resolution: Received, reviewed and accepted class report/ proper documentation from LR stating the deficiency was rectified. Painted over secondary loadline and was issued interm loadline certificate from LR.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.