Records from 2000 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 49
28 April 2026
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8357424
3 February 2026
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8305486
28 October 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8260015
27 February 2025
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8085591
29 October 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8026389
22 April 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7899490
8 February 2024
Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7862864
19 July 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7746658
22 January 2023
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7625337
13 October 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7576421
28 March 2022
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7419652
26 January 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7386096
17 August 2021
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7289094
29 July 2021
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7275916
15 April 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7175575
22 October 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7082348
5 February 2020
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6903116
8 October 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6830634
10 March 2019
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6641327
11 October 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6559090
14 April 2018
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 6391758
21 February 2018
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6358588
11 October 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6284871
20 September 2016
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6004847
5 March 2016
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5932741
16 February 2016
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5815616
15 September 2015
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5719301
16 August 2015
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5219583
7 February 2012
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4239861
20 September 2011
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4149057
14 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3849398
23 February 2010
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3684417
3 October 2008
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 3338807
16 September 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3325884
3 May 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3201909
25 February 2008
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3152922
8 January 2008
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3127441
6 November 2007
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3093809
29 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2977551
14 July 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2712606
28 February 2006
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2593145
17 November 2005
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2536313
16 November 2004
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2241818
9 March 2004
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2021120
18 January 2004
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2024108
28 October 2003
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1937403
25 September 2002
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1742801
9 September 2002
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1667662
21 April 2000
Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1449330
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 October 2024
Resolved
The marine employer must have sufficient alcohol testing devices readily accessible. Devices expired. Vessel must be able to conduct alcohol tests within 2 hours.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2024
Resolved
Each floating water light must be approved in accordance with 161.010 in subchapter Q. Life buoy light must be attached with corrosion resistant clip. Waterlight not approved under 161.010. Restricted to daytime operations. Clip missing.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2024
Resolved
Waste receptacles must be constructed of noncombustible materials. Head waste receptable combustible.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 12 November 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 October 2024
Resolved
An EAP program must include the following elements: Supervisory personnel must receive at least 60 minutes of training. No proof of training provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 22 November 2024
Resolution: Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2024
Resolved
Electrical equipment must be installed and maintained to provide service necessary. Light fixture in laz is unwired and inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 12 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 October 2024
Resolved
A vessel not required to have a fire pump must have at least 3 buckets with attached lanyard. The words "FIRE BUCKET" must be stenciled on each bucket. Lanyards and stencile missing. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 October 2024
Resolved
Monthly inspection required by NFPA 10 may be conducted by the owner, operator, or person-in-charge. Monthly inspections of fire extinguishers not being conducted. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 29 October 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 October 2023
Resolved
Each vessel that operates on the high seas must have on board a EPIRB. EPIRB battery expired. Vessel restricted to three miles from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 October 2023
Resolution: New EPIRB installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 October 2023
Resolved
As appropriate for the intended voyage, a vessel must carry up-to-date: charts, U.S. Coast Pilot [name withheld] List, Tides Tables, and Current Tables. Extracts from the publications may be provided. Charts and pubs out-of-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: All publications provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers and crew. Extension cord being used as permanent wiring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 20 October 2023
Resolution: Removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2023
Resolved
A vessel must be provided with bilge pumps. Individual power pumps used for separate spaces are to be controlled from a central point and must have a light or other visual means to indicate operation. Light at operating station inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 20 October 2023
Resolution: Indicating lights operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 October 2023
Resolved
The master of the vessel shall ensure that: each EPIRB, other than ILR, must be tested monthly. Monthly test not being conducted.
Action required: 10 - Deficiency Rectified
Resolved 5 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 July 2023
Resolved
Vessel must have and interconnected fire/alarm detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access including accommodation and machinery spaces. Provide diagram showing location and type of detectors to be installed. Install equipment by 19OCT2023.
46 CFR 181.405
Action required: 705 - Other - as specified
Due 19 October 2023
Resolved 5 October 2023
Resolution: Diagram provided. Installation verified and system tested.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 October 2022
Resolved
Port and starboard boarding ladder hand rail stanchion's mounting welds are cracked. Repair welds or replace stanchions prior to passenger or crew using ladders.
46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Repairs made SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 October 2022
Resolved
Masthead light inoperative. Repair/replace light to the satisfaction of marine inspector. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Masthead light operates SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 October 2022
Resolved
FCC Station License expired. Provide current license. Operations restricted to no more than 1000 feet from shore.
47 CFR 80.13
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Current license provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 October 2022
Resolved
Pre-engineered fire extinguishing system system charged light is inoperative. Repair/replace light. 46 CFR 181.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 20 October 2022
Resolution: Panel replaced. Light operating SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2022
Resolved
Provide proper life jacket donning placard for new type of life jackets onboard. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 14 October 2022
Resolution: Donning placard provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 October 2022
Resolved
Life float oars to be labeled with vessel's name.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 14 October 2022
Resolution: Oars properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 November 2020
Resolved
Masthead light configuration is not IAW navigation rules. Adjust height of masthead light to allow for the correct arc of visibility. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 30 November 2020
Resolution: Nav light configuration SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2020
Resolved
1 adult life jacket non-serviceable. Replace life jacket with approved type. Total person allowed reduced to 15.
46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 30 November 2020
Resolution: Life jacket replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 November 2020
Resolved
Lazerette watertight hatch is missing securing device. Install securing device to watertight hatch. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 30 November 2020
Resolution: Securing device attached.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 November 2019
Resolved
Emergency fuel shut off valves do not close. Repair valves prior to carrying passengers. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2019
Resolution: Cables to valves replaced. Valves close when cables pulled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2019
Resolved
41 life jackets non-serviceable. Total adult count reduced to 4 and child count remains at 6. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 6 November 2019
Resolution: 45 approved adult life jackets with lights, retro and labeling onboard replacing non-serviceable jackets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 November 2019
Resolved
Bilge high level visual alarm inoperative for the mid-void space. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 19 November 2019
Resolution: Alarms SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 November 2019
Resolved
Lazerette watertight hatch does no close properly. Repair hatch to make watertight. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 19 November 2019
Resolution: Hatch seals SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 November 2019
Resolved
Port and stbd boarding ladders mounting hardware found loose. Tighten all hardware to make ladders secure.
46 CFR 177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 19 November 2019
Resolution: Ladders secured SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2019
Resolved
Replace non-serciveable retro-reflective tape on both life floats. 46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 19 November 2019
Resolution: Tape replaced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 October 2018
Resolved
Demonstrate operation of the following bilge alarm lights: FWD, MID, AFT and ensure audible aft alarm is functioning.
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 18 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2018
Resolved
Renew ring lifebuoy.
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 18 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 October 2018
Resolved
Renew smoke detector.
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 18 October 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 11 October 2018
Resolved
Ensure both captains employed have valid marine radio operator permits or at least one crewmember on board vessel holds one.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 7 December 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 October 2018
Resolved
Install on 7.87" bell
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 18 October 2018
Construction/Loadline › Hull › Bottom Plating
Issued 21 February 2018
Resolved
Repair small blister on hull as discussed with CGMI.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Owner repaired the blister.
Engineering › Reduction Gearing/Clutches › Hose
Issued 21 February 2018
Resolved
Replace wasted shift cable.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Owner replaced the shift cable.
Stability › Watertight Integrity › General
Issued 21 February 2018
Resolved
Replace handle for head through hull valve.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Owner replaced handle for through hull valve.
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 February 2018
Resolved
Re-attach bonding wire IWO head through hull valve.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Owner re-attached all bonding wire.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 February 2018
Resolved
Repair cracks in dive platform as discussed with CGMI.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Owner had all cracks in dive platform welded.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 February 2018
Resolved
Seal fwd bulkhead penetrations.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Owner sealed the forward engine room bulkhead.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 February 2018
Resolved
Re-attach guard for exposed hazard.
Action required: 705 - Other - as specified
Resolved 23 February 2018
Resolution: Engine guards installed properly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 September 2016
Resolved
Prove proper operation of bilge alarm in fuel tank compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2016
Resolution: Proved proper operation of bilge alarm
Communications › Radio Communications › EPIRB
Issued 20 September 2016
Resolved
Prove proper operation of epirb prior to going beyond 3 miles from shore.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 23 September 2016
Resolution: Owner has replaced epirb.
Stability › Watertight Integrity › General
Issued 16 February 2016
Resolved
Re-new hatch gaskets on two engine room hatches.
Due 19 February 2016
Resolved 25 February 2016
Resolution: Hatch gaskets have been renewed.
Stability › Watertight Integrity › General
Issued 16 February 2016
Resolved
Install metallic cap or plug on through hull valve that is not being used.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2016
Resolution: Metallic cap has been installed on through hull valve.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 20 September 2011
Resolved
Show proof of MIS submission IAW 46 CFR 16.500.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 23 September 2011
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 20 September 2011
Resolved
Show proof of pre-employment testing documentation.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 23 September 2011
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 September 2011
Resolved
Show proof of required test records and reports.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 23 September 2011
Communications › Radio Communications › EPIRB
Issued 20 September 2011
Resolved
Replace expired EPIRB battery, vessel is restricted to operating not more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 23 September 2011
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 16 September 2008
Resolved
sea strainer bowl must renew plug
Action required: 705 - Other - as specified
Due 23 September 2008
Resolved 23 February 2010
Communications › Radio Communications › EPIRB
Issued 16 September 2008
Resolved
EPIRB antenna worn and almost wasted. must renew antenna- vessel restricted to within 3 miles of shore until renewed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 16 September 2008
Resolved
Improper drug testing enrollment verification format. must provide current proof of enrollment
Condition: Improper/Lack of Maintenance
Due 23 September 2008
Resolved 17 September 2008
Engineering › Bilge Water Management System › Pump
Issued 6 November 2007
Resolved
Provide and install electrical submersible bilge pumps that are U/L, FM or other independant lab listed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 8 January 2008
Construction/Loadline › Hull › Weld
Issued 28 February 2006
Resolved
Properly repair aft dive embarkation platform by grinding out old cracks and rewelding
Due 3 March 2006
Resolved 3 March 2006
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 28 February 2006
Resolved
Renew port and starboard strut (cutlass) bearings.
Due 3 March 2006
Resolved 3 March 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 28 February 2006
Resolved
Make engineroom hatch watertight.
Condition: Improper/Lack of Maintenance
Due 31 March 2006
Resolved 7 November 2006
Resolution: Made engineroom hatch watertight
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 February 2006
Resolved
Properly and permanently close all drain holes in transverse bulkheads
Condition: Design Flaw
Due 3 March 2006
Resolved 3 March 2006
Stability › Watertight Integrity › General
Issued 28 February 2006
Resolved
Remove door in the collision bulkhead and install a permanent watertight cover over the opening
Due 31 March 2006
Resolved 7 November 2006
Resolution: Verified opening located in the collision bulkhead was made watertight.
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 28 February 2006
Resolved
Vessel constructed of General Purpose resin. Deck above engine room and engine room forward bulkhead are to be lined with non combustible panels or insulation approved IAW 46CFR164.009.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 December 2006
Resolved 5 December 2006
Resolution: Done
Fire Fighting › Combustible Materials › Linings
Issued 17 November 2005
Resolved
Provide proof engine room insulation meets requirements of 46 CFR 164.009.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 5 December 2005
Resolution: Owner removed all foam from engineroom
Engineering › Fuel Oil Service System › Valve
Issued 17 November 2005
Resolved
Install shut off valves at the port and starboard engine fuel lines at the engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 5 December 2005
Engineering › Bilge Water Management System › Valve
Issued 17 November 2005
Resolved
Install positive shut off valves in electrical submersible bilge pumps discharge lines at the spool piece in hull with no hose between the hull and the valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 5 December 2005
Engineering › Fuel Oil Service System › Hose
Issued 17 November 2005
Resolved
Install new fuel line (supply and return) to port and starboard engines, that meets the SAE J-1942 standard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 5 December 2005
Documentation › Logs/Records › Drug Test Records
Issued 17 November 2005
Resolved
Provide proof of current drug testing program.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 November 2005
Resolved 5 December 2005
Lifesaving › Hand Flares › Quantity
Issued 28 October 2003
Resolved
Provide 6 red night flares and 6 day orange flares, prior to carrying passengers, as per 46CFR180.68.
Due 29 October 2003
Resolved 29 October 2003
Lifesaving › Buoyant Apparatus
Issued 28 October 2003
Resolved
Repair life float outer coating where damaged.
Due 29 October 2003
Resolved 29 October 2003
Engineering › Bilge Water Management System › Valve
Issued 28 October 2003
Resolved
Install positive shut off valves on all bilge pump thru hull fittings, as per 46CFR179.350.
Due 29 October 2003
Resolved 29 October 2003
Engineering › Bilge Water Management System
Issued 28 October 2003
Resolved
Identify all high water alarms at the control station, as per 46CFR176.804.
Due 29 October 2003
Resolved 29 October 2003