MAURY USCG vessel records Sign in
← All vessels

NORTHERN OCEAN

NORTHERN OCEAN is a 2005 tank ship. The Coast Guard has recorded 19 inspections since 2005, most recently in April 2021, along with 6 deficiencies and 4 operational controls.

Records from 2005 to 2021. Most recent: operational control imposed, 5 April 2021.

Built
2005
Last inspected
4 April 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9298492 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
787691
Flag
MARSHALL ISLANDS
—
Maury page id
psix-787691

Inspections, by type

…with no type recorded9
Years with a record 9 calendar years (2005–2021)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30053 - Convention (Subpart B), Gross Ton
13712 - Convention (Subpart B), Net Ton
50922 - Dead Weight, Ton
62031 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

4 April 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7167689
4 April 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7168240
4 April 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175154
8 April 2018 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6387439
10 June 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4885387
2 June 2014 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4874357
10 July 2012 COC-CHEM Annual · PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4330116
9 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4372564
8 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4380657
12 February 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3417020
7 December 2008 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3375007
11 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3096489
11 November 2007 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3096637
6 July 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2985415
7 January 2007 COC-TVE Annual · ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2849588
18 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2781737
15 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2779314
4 November 2005 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2528169
5 September 2005 ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486284

Deficiency record · 6

Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 10 July 2012 Resolved
1400 - Propulsion & Auxiliary Machinery - On 08 Jul 2012, vessel experienced a power irregularity at Southwest Pass Light 8 due to a faulty #3 fuel injection pump. - SOLAS 74(a) I/11.
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. No.3 fuel injection pump was renewed and tested to the satisfaction of the class surveyor.
Communications › Audible Communications › Horn/Whistle
Issued 7 December 2008 Resolved
The High Level Alarm was not working due to a faulty horn. See Narrative for details.
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 12 February 2009
Resolution: Received Technician report from Sperry Marine satisfying requirement.
Operations/Management › Navigation Safety › Navigation Underway, Tankers
Issued 7 December 2008 Resolved
The Voyage Data Recorder was inoperable. Required a technician's report. See Narrative for details.
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 10 December 2008
Resolution: Cleared with tech report from Sperry Marine.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 11 November 2007 Resolved
Emergency fire pump is inoperable. The vessel must submit Class report prior to departure from Sector Houston-Galveston area.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2007
Resolution: RCDO received technician report. The emergency fire pump is working properly. The vessel has been released from OPCON.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 January 2007 Resolved
Loadlines are not permanently welded on the hull. To be done at next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 August 2007
Resolution: Received class report attesting to the permanent affixing of the vessel''s loadline.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 September 2005 Resolved
THE VAPOR CONTROL SYSTEM FLANGE STUDS ARE NOT PERMANENTLY ATTACHED, BUT ARE ADJUSTABLE. PROVIDE PERMANENT STUDS ON ALL VCS FLANGES PRIOR TO USING VCS IN US WATERS.
Action required: 705 - Other - as specified
Resolved 4 November 2005
Resolution: VESSEL PROVIDED REPORT ATTESTING TO PERMANENT STUDS ON ALL VCS FLANGES

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.