TORM SARA

TORM SARA is a 2003 tank ship. The Coast Guard has recorded 24 inspections since 2006, most recently in March 2023, along with 12 deficiencies and 5 operational controls.

Records from 2006 to 2023. Most recent: inspection, 14 March 2023.

Built
2003
Last inspected
14 March 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9273260 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
787862
Flag
SINGAPORE
—
Maury page id
psix-787862

Inspections, by type

…with no type recorded7
Years with a record 11 calendar years (2006–2023)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41503 - Simplified, Gross Ton
20972 - Simplified, Net Ton
41503 - Convention (Subpart B), Gross Ton
20972 - Convention (Subpart B), Net Ton
86139 - Displacement, Ton
72718 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

14 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7651189
7 March 2023 PSC B · COC-TVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7643756
26 November 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7599734
11 March 2022 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7410079
6 August 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7025807
26 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7016341
12 March 2020 COC-TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925156
27 April 2019 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6671442
26 August 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6522838
31 May 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6430013
30 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6429677
29 May 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6427620
20 March 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6374451
5 June 2012 ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4334489
31 August 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4131805
11 March 2009 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3431167
11 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3431782
9 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3430623
28 August 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3311007
23 January 2008 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3134760
5 July 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2984512
10 April 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2904700
23 January 2006 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2571281
23 January 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2571928

Deficiency record · 12

Deck/Cargo › Inert Gas System › IGS Blower
Issued 20 March 2018 Resolved
#2 Blower has excessive vibration
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 April 2018
Resolved 29 May 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2018 Resolved
Multiple explosion proof lighting fixtures show cracking, compromised seals and missing ground wires.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 April 2018
Resolved 29 May 2018
Construction/Loadline › Structures › Deck Plating
Issued 20 March 2018 Resolved
Anchor windlass shield coverings have been cracked and torn from mount.(ICLL 66 Art 15)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 April 2018
Resolved 29 May 2018
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 31 August 2011 Resolved
Clamps holding the adjustable dogs on site glass are fractured. There are 2 sides to the clamps holding the dogs in place. Top clamp has 1 fractured clamp. Aft clamp has both clamps fractured & fwd clamp found to be fully intact. Potential for oxygen to be introduced into IGS at an uncontrollable rate & cause an usafe condition. --Class approved temp repairs & gave 30 days to make perm repair.
Action required: 705 - Other - as specified
Due 2 October 2011
Resolved 22 September 2011
Documentation › Manuals/Policy Documentation › Crude Oil Washing Operations/Equipment Manual
Issued 31 August 2011 Resolved
IGS manual has no approval stamp or documentation showing system has been reviewed, installed and approved by Administration.
Action required: 705 - Other - as specified
Due 31 August 2011
Resolved 1 September 2011
Resolution: Received class (LR) report verifying the IGS system has been reviewed and approved by the previous class (ABS) and endorsed by the current class (LR). Cert No. KJ351189-X2
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 31 August 2011 Resolved
Deep fat fryer in the galley only has a portable CO2 extinguisher and fire blanket as fire protection. Also, there is no evidence of a manual or automatic system which should also secure electrical power in this space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2011
Resolution: Class (LR) has attested to a 6.8 Kg CO2 portable extinguisher & fire blanket being in galley (to provide fire protection). Additionally, the #5 breaker switch in panel in galley is labeled with instructions to turn off in event of fire.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 31 August 2011 Resolved
Vessel has four inflatable life reafts . As manufactueres instructions, there should be a weak link between the sea painter and the life raft bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 September 2011
Resolution: Received report from class (LR) of proper Hydrostatic Release has been installed on each of the four inflatable life rafts.
Construction/Loadline › Markings › Load Line Mark
Issued 31 August 2011 Resolved
The load line on the port side is marked with previous class society initials (AB for ABS). Five years ago the vsl was reclassifed under Lloyd's Registery (LR). LR has given the vsl until next dry dock to make corrections to the permanently affixed class initials. However, until the next dry dock (2013) the vsl should maintain the painted symbols to reflect the correct symbol and information.
Due 7 September 2011
Resolved 22 September 2011
Fire Fighting › Means of Escape › Doorways
Issued 10 April 2007 Resolved
Provide method of securing door to the steering gear room allowing access to the fire pump and escape from inside. 70a SOLAS 74/78 CH II-2/10.2.2.3.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2007
Resolution: Rcvd fax class report stating access/egress has been resolved.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 April 2007 Resolved
Emergence Generator is unable to start in automatic mode. Provide a continuous watch in the emergence generator room while transiting to navigable waters of the U.S. in order to manually start the E.G. 70a IMO Resolution 787(19)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2007
Resolution: rcvd fax class report stating the Emergency generator has been repaired and is now functioning properly.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 10 April 2007 Resolved
All 14 tanks (12 cargo and 2 slops) above 8% Oxygen. 10 SOLAS 74/78 Ch. 10/62.2.2
Action required: 705 - Other - as specified
Resolved 10 April 2007
Resolution: Deficiency rectified
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 24 January 2006 Resolved
Scrubber drain line, at the first flange, at the bottom of the scrubber tower there is a fiberglass band around the drain pipe. Prior to next US Port after going foreign provide to the US Coast Guard a report from Class, as to the condition of the area around the flange and the need for the fiberglass patch.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 April 2007
Resolution: Inspected deficiency and viewed Class report. All Sat

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.