← All vessels
TORM SARA
TORM SARA is a 2003 tank ship. The Coast Guard has recorded 24 inspections since 2006, most recently in March 2023, along with 12 deficiencies and 5 operational controls.
Records from 2006 to 2023. Most recent: inspection, 14 March 2023.
- Built
- 2003
- Last inspected
- 14 March 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9273260 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
S6AA9
787862
Flag
SINGAPORE
—
Maury page id
psix-787862
Inspections, by type
…with no type recorded7
Years with a record
11 calendar years (2006–2023)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it41503 - Simplified, Gross Ton
20972 - Simplified, Net Ton
41503 - Convention (Subpart B), Gross Ton
20972 - Convention (Subpart B), Net Ton
86139 - Displacement, Ton
72718 - Dead Weight, Ton
20972 - Simplified, Net Ton
41503 - Convention (Subpart B), Gross Ton
20972 - Convention (Subpart B), Net Ton
86139 - Displacement, Ton
72718 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
14 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7651189
7 March 2023
PSC B · COC-TVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7643756
26 November 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7599734
11 March 2022
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7410079
6 August 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7025807
26 July 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7016341
12 March 2020
COC-TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925156
27 April 2019
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6671442
26 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6522838
31 May 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6430013
30 May 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6429677
29 May 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6427620
20 March 2018
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6374451
5 June 2012
ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4334489
31 August 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4131805
11 March 2009
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3431167
11 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3431782
9 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3430623
28 August 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3311007
23 January 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3134760
5 July 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2984512
10 April 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2904700
23 January 2006
Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2571281
23 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2571928
Deficiency record · 12
Deck/Cargo › Inert Gas System › IGS Blower
Issued 20 March 2018
Resolved
#2 Blower has excessive vibration
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2018
Resolved
Multiple explosion proof lighting fixtures show cracking, compromised seals and missing ground wires.
Construction/Loadline › Structures › Deck Plating
Issued 20 March 2018
Resolved
Anchor windlass shield coverings have been cracked and torn from mount.(ICLL 66 Art 15)
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 31 August 2011
Resolved
Clamps holding the adjustable dogs on site glass are fractured. There are 2 sides to the clamps holding the dogs in place. Top clamp has 1 fractured clamp. Aft clamp has both clamps fractured & fwd clamp found to be fully intact. Potential for oxygen to be introduced into IGS at an uncontrollable rate & cause an usafe condition. --Class approved temp repairs & gave 30 days to make perm repair.
Documentation › Manuals/Policy Documentation › Crude Oil Washing Operations/Equipment Manual
Issued 31 August 2011
Resolved
IGS manual has no approval stamp or documentation showing system has been reviewed, installed and approved by Administration.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 31 August 2011
Resolved
Deep fat fryer in the galley only has a portable CO2 extinguisher and fire blanket as fire protection. Also, there is no evidence of a manual or automatic system which should also secure electrical power in this space.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 31 August 2011
Resolved
Vessel has four inflatable life reafts . As manufactueres instructions, there should be a weak link between the sea painter and the life raft bracket.
Construction/Loadline › Markings › Load Line Mark
Issued 31 August 2011
Resolved
The load line on the port side is marked with previous class society initials (AB for ABS). Five years ago the vsl was reclassifed under Lloyd's Registery (LR). LR has given the vsl until next dry dock to make corrections to the permanently affixed class initials. However, until the next dry dock (2013) the vsl should maintain the painted symbols to reflect the correct symbol and information.
Fire Fighting › Means of Escape › Doorways
Issued 10 April 2007
Resolved
Provide method of securing door to the steering gear room allowing access to the fire pump and escape from inside. 70a
SOLAS 74/78 CH II-2/10.2.2.3.2.2
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 April 2007
Resolved
Emergence Generator is unable to start in automatic mode. Provide a continuous watch in the emergence generator room while transiting to navigable waters of the U.S. in order to manually start the E.G. 70a
IMO Resolution 787(19)
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 10 April 2007
Resolved
All 14 tanks (12 cargo and 2 slops) above 8% Oxygen. 10
SOLAS 74/78 Ch. 10/62.2.2
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 24 January 2006
Resolved
Scrubber drain line, at the first flange, at the bottom of the scrubber tower there is a fiberglass band around the drain pipe. Prior to next US Port after going foreign provide to the US Coast Guard a report from Class, as to the condition of the area around the flange and the need for the fiberglass patch.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.