Records from 2005 to 2015. Most recent: inspection, 9 October 2015.
Inspection history · 19
9 October 2015
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5738449
7 October 2015
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5737383
4 October 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5735039
4 October 2015
ISPS III Exam · In-Service Inspection · NPV Safety Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5735044
4 October 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5736643
24 July 2015
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5194185
18 November 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3365383
17 November 2008
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3364442
10 April 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3181556
29 October 2007
PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3088862
26 April 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2916283
10 October 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2797679
9 October 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2796908
7 October 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2795713
29 June 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2695356
1 February 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2577544
12 September 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2490167
11 September 2005
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2489204
10 September 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2489067
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 October 2015
No resolution recorded
0799 The purpose of this regulations is to maintain & monitor the effectiveness of the fire safety measures the vsl is provided with. Fire protection systems & fire-fighting systems and appliances shall be maintained ready for use. During the deck portion walk PSCOs observed 4 ventilation dampers were seized. Crew had to use alternative means to secure dampers. SOLAS con ed 04 II-2/14.1.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Generation Source (service) › Generator
Issued 6 October 2015
Resolved
The condition of the ship and its equipment shall be maintained to conform wit the present regulations to ensure the ship is fit to proceed to sea without danger to ship or persons on board. PSCO found fuel oil leaking on #3 generator at a rate of 3 drips every 30 seconds on top of the engine block. 74 SOLAS (14 CONS) Ch. I Reg. 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the #3 generator.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 4 October 2015
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO FOUND FUEL OIL POURING FROM M/E #3 CYLINDER FUEL INJECTOR WHILE OPERATING.74 SOLAS (04 CONS) Ch. II-2 / Reg. 4.1.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the main engine #3 cylinder fuel injector.
Engineering › Fuel Oil Service System › Pump
Issued 4 October 2015
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO FOUND FUEL OIL POURING FROM THE #2 FUEL SUPPLY PUMP IN THE PURIFIER ROOM.74 SOLAS (04 CONS) Ch. II-2 / Reg. 4.1.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the #2 fuel pump in the purifier room.
Electrical › Electric Generation Source (service) › Generator
Issued 4 October 2015
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PRESENT REGULATIONS TO ENSURE THE SHIP IS FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. PSCO FOUND EXCESSIVE FUEL OIL LEAKING INTO A BUCKET UNDER THE #1 SHIP SERVICE GENERATOR.74 SOLAS (14 CONS) Ch. I Reg. 11(a) - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the #1 ship service generator.
Electrical › Electric Generation Source (service) › Generator
Issued 4 October 2015
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PRESENT REGULATIONS TO ENSURE THE SHIP IS FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. PSCO FOUND EXCESSIVE FUEL OIL LEAKING INTO A BUCKET UNDER THE #2 SHIP SERVICE GENERATOR.74 SOLAS (14 CONS) Ch. I Reg. 11(a) - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the #2 ship service generator.
Electrical › Electric Generation Source (service) › Generator
Issued 4 October 2015
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PRESENT REGULATIONS TO ENSURE THE SHIP IS FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. PSCO FOUND EXCESSIVE FUEL OIL LEAKING INTO A BUCKET UNDER THE #3 SHIP SERVICE GENERATOR.74 SOLAS (14 CONS) Ch. I Reg. 11(a) - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the #3 ship service generator.
Engineering › Steam System (auxiliary) › Valve, Control
Issued 4 October 2015
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO FOUND EXCESSIVE FUEL OIL LEAKING INTO A BUCKET UNDER THE #1 STEAM HEATING CYLINDER IN THE PURIFIER ROOM.74 SOLAS (04 CONS) Ch. II-2 / Reg. 4.1.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the #1 steam heating cylinder in the purifier room.
Engineering › Steam Boiler (auxiliary/waste heat) › Blowdown System
Issued 4 October 2015
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO FOUND EXCESSIVE FUEL OIL LEAKING INTO A BUCKET UNDER THE BOILER'S BLOWER.74 SOLAS (04 CONS) Ch. II-2 / Reg. 4.1.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the boiler's blower.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 October 2015
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO FOUND FUEL OIL LEAKING FROM THE EMERGENCY GENERATOR'S REMOTE FUEL SHUT-OFF VALVE.74 SOLAS (04 CONS) Ch. II-2 / Reg. 4.1.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the emergency generator fuel shut-off valve.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 October 2015
Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE ISM CODE. THE COMBINED SIGNIFICANCE OF THE ABOVE DEFICIENCIES INDICATE A SUBSTANTIAL NON-COMPLIANCE WITH THE ISM CODE, AND MAY POSE A SERIOUS THREAT TO SHIP AND CREW. [name withheld] ISM AUDIT.74 SOLAS (14 CONS) Ch. IX Reg. 3.1 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: External audit was conducted and found satisfactory.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 October 2015
Resolved
FIRE-RESISTING DIVISIONS SHALL BE KEPT IN GOOD ORDER TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. BOTH FIRE DOORS LEADING TO THE PURIFIER ROOM FOUND SECURED OPEN WITH WIRE.74 SOLAS (04 CONS) Ch. II-2 Reg. 14.2.1.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the fire doors leading to the purifier room.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 4 October 2015
Resolved
AFTER ANY SURVEY OF THE SHIP, NO CHANGE SHALL BE MADE IN THE MACHINERY OR EQUIPMENT WITHOUT THE SANCTION OF THE ADMINISTRATION. DOORS LEADING TO TRANSFORMERS FOUND SECURED OPEN WITH WIRE CREATING A SIGNIFICANT ELECTRICAL SHOCK HAZARD.74 SOLAS (14 CONS) Ch. I Reg. 11(b) - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2015
Resolved 6 October 2015
Resolution: Received class report attesting to the satisfactory condition of the door leading to the transformers.
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 November 2008
Resolved
During Ops test of emergency generator 2nd method of starting inoperable. Hydraulic system was unable to start the engine. Ship crew to repair and demonstate proper operation of 2nd means of starting to satisfaction of attending class surveyor prior to departure from port of NY. SOLAS 74 Ch II-1 Reg 44
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2008
Resolution: Recieved Class report from CCS Surveyor. Deficiency Cleared.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 29 October 2007
Resolved
Vessel provided incorrect name and contact information for Company Security Officer (CSO). Vessel must submit update to reflect correct name and contact info for CSO as listed in the Ship's Security Plan (SSP) prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2007
Resolution: Vessel updated ANOA with correct information.