TD-1 is a passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2005, most recently in June 2017, along with 14 deficiencies and 3 operational controls.

Records from 2005 to 2017. Most recent: inspection, 19 June 2017.

Built
Not recorded
Last inspected
19 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF5546
787982
Flag
UNITED STATES
—
Maury page id
psix-787982

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2005–2017)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it9 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

19 June 2017 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6180290
3 October 2014 In-Service Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4998600
23 June 2014 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4897787
16 July 2012 Annual Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4381085
9 February 2012 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4241788
27 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4095681
26 July 2011 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4095923
26 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4109471
8 September 2010 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3845625
3 March 2010 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3689056
10 June 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3233232
10 June 2008 Examination of Repairs · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3245541
1 May 2008 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3196254
25 February 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3153191
25 January 2007 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2859680
10 January 2007 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2853604
14 March 2006 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2602231
10 December 2005 Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2549239
27 November 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2541172
24 October 2005 Construction Oversight · Deadweight Survey · Simplified Stability Test · Initial Certification · Inclining Experiment · Internal Structural Exam · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2501643
6 September 2005 Plan Review "T" Boat · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2485297

Deficiency record · 14

Engineering › Bilge Water Management System › Piping
Issued 3 October 2014 Resolved
Properly install suitable hoses for all (03) bilge piping systems on each vessel, secure with double hose clamps, and prove proper operation of removing water from each space prior to carrying passengers for hire. 46CFR182.520(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2014
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 23 June 2014 Resolved
Make proper repairs to seal for drive train to main shaft. (46CFR 176.830(a))
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2014
Resolution: Renewed seal.
Construction/Loadline › Hull › Bottom Plating
Issued 23 June 2014 Resolved
Renew stiffner inboard and foward inside wheel well towards port axel.
Due 14 August 2014
Resolved 21 August 2014
Resolution: Cancelled Deficiency.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 July 2012 Resolved
Vessel has not completed an annual inspection within the allotted time frame. Complete Annual Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2012
Resolution: Annual inspection was successfully completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 July 2011 Resolved
Prove proper servicing for the vessels CO2 system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 July 2011 Resolved
Provide cause of vessel overheat and complete necessary repairs. Provide signed report from company maintenence personnel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 25 January 2007 Resolved
Provide operating instructions for the fixed CO2 system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2007
Resolved 25 February 2007
Resolution: Instructions posted.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2007 Resolved
Show operation of stern light.
Due 25 February 2007
Resolved 26 February 2007
Resolution: light working.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 January 2007 Resolved
Install and show operation of VHF radio.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2007
Resolved 26 February 2007
Resolution: installed and working.
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 January 2007 Resolved
Show operation of both curtain releases.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2007
Resolved 26 February 2007
Resolution: curtains operational.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 October 2005 Resolved
Properly mark vessels name onto hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 24 October 2005 Resolved
Proplerly install bonding strap from fuel fill pipe to fuel tank (separted by a section of hose).
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2005
Resolved 29 November 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 24 October 2005 Resolved
Properly Hydro Test vessels fuel storage tank in the presence of a CG Marine Inspector.
Action required: 705 - Other - as specified
Due 24 November 2005
Resolved 29 November 2005
Personnel › Training › Fire Fighting Basic
Issued 24 October 2005 Resolved
Properly conduct emergency drills and training with vessels Master.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2005

Ownership record