NAVE DORADO is a 2005 tank ship. The Coast Guard has recorded 27 inspections since 2005, most recently in June 2022, along with 6 deficiencies and 3 operational controls.

Records from 2005 to 2022. Most recent: inspection, 24 June 2022.

Built
2005
Last inspected
24 June 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9325336 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
787983
Flag
PANAMA
—
Maury page id
psix-787983

Inspections, by type

…with no type recorded7
Years with a record 14 calendar years (2005–2022)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28799 - Regulatory (Subpart C or D), Gross Ton
12962 - Regulatory (Subpart C or D), Net Ton
47999 - Dead Weight, Metric Ton
57326 - Displacement, Metric Ton
28799 - Convention (Subpart B), Gross Ton
12962 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

24 June 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7485788
22 June 2022 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7484181
13 February 2022 PSC B · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7394930
13 February 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7395885
7 February 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7391739
4 December 2020 Ballast Water Examination · COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7103721
19 May 2019 Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6688853
18 November 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6582980
20 June 2018 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6449849
1 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6227266
23 June 2017 ISPS II Exam · COC-TVE Renew · Ballast Water Examination · COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6184208
19 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180596
8 August 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5965805
22 March 2016 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5831879
28 August 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5228478
24 August 2015 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5224656
16 March 2014 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4816840
6 January 2011 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3921183
4 November 2010 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3885214
30 March 2010 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3705283
4 March 2009 COC-TVE Annual · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3424452
4 November 2007 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3092454
16 August 2006 STCW 95 Exam · ILO-147 Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2749696
26 April 2006 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2635883
14 September 2005 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2492613
10 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2488988
10 September 2005 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2489429

Deficiency record · 6

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 February 2022 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS, AND INSTRUCTIONS, INCLUDING CHECKLISTS AS APPROPRIATE, FOR KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF PERSONNEL, SHIP, AND PROTECTION OF THE ENVIRONMENT. VESSEL IS CERTIFICATED TO OPERATE W/ AN UNMANNED MACHINERY SPACE. PSCO IDENTIFIED ENGINE ROOM HAD BEEN SECURED AND UNMANNED ON A REGULAR BASIS, PER THE ENGINEER'S LOG BOOK. UPON FURTHER INVESTIGATION, VESSEL HAS UMS PROCEDURE (TE-34) THAT REQUIRES INSPECTION OF THE WATERMIST PANEL PRIOR TO SECURING THE WATCH. SMS CH 02 (ENGINE ROOM WATCH KEEPING) STATES THAT PRIOR TO GOING UNMANNED, THE CREW SHALL CHECK ALL AUTOMATIC CONTROL SYSTEMS. CREW STATED THAT TESTS WERE CONDUCTED 2 DAYS AGO AND FORGOT TO SWICH BACK TO AUTOMATIC MODE. TESTING DOCUMENTS SHOW PUMP TESTED DEC 18,2021. [name withheld] AUDIT TO VERIFY PROPER PROCEDURES ARE FOLLOWED ONBOARD. 74 SOLAS (20) IX/3.1 ISM CODE A/7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2022
Resolved 14 February 2022
Resolution: Port State Control Duty Officer reviewed the class report for an ISM Audit and deemed the results to be satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 February 2022 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. WATERMIST SYSTEM WAS FOUND IN THE MANUAL MODE. CREW SWITCHED MODE BACK TO AUTOMATIC. 74SOLAS(04) II-2/14.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 February 2022
Resolution: PSCO OBSERVED CREW SWITCH WATERMIST SYSTEM INTO AUTOMATIC MODE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 May 2019 Resolved
Means shall be provided to limit the accuulation of flammable vapours. Attomized fuel sprays from the #5 cylinder indicator cock on the #2 generator while rolling the engine over. (74 SOLAS (04) II-2/4.1.2
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 21 May 2019
Resolution: Crew replaced worn injector which was leaking fuel into the cylinder.
Construction/Loadline › Markings › Load Line Mark
Issued 23 June 2017 Resolved
The lines shall be painted in white on a dark ground. They shall be permanently marked on the sides of the ships. The vessel has multiple loadlines none of which were clearly painted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2017
Operations/Management › Pollution › Shipboard Incineration
Issued 22 March 2016 Resolved
1720-Control of discharge-Every ship 400GT and above shall be provided with a tank capacity having regard to the type of machinery and length of voyage to receive sludge. In lieu of meeting tank size regulations vessel may have on board an incinerator certified to burn sludge. Vessel's incinerator is not operational. - MARPOL Annex I/Reg 12
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 11 April 2016
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 10 September 2005 Resolved
Deck overfill alarm not labeled. Vessel is required to label the alarm to the satisfaction of USCG Port State Control Officer. 46CFR39.20-9
Due 17 September 2005
Resolved 19 September 2005
Resolution: Received a picture attachement from agent showing the overfill alarm stenciling has been done. All sat.