MSC SANTA MARIA is a 2005 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in September 2022, along with 4 deficiencies and 4 operational controls.
Records from 2016 to 2022. Most recent: inspection, 18 September 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it67273 - Dead Weight, Metric Ton 87829 - Displacement, Metric Ton 54809 - Convention (Subpart B), Gross Ton 34226 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022Resolved
After any survey of the ship under regulations 7, 8, 9, 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration. PSCO observed nonapproved fan cooling the #1 cylinder lubricating pump for the RPLS.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 September 2022
Resolution: SHG PSC received attestation from vessel's master that the unapproved fan has been removed. See attached image of the same being recorded in the ship's log book.
ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED SO THAT THE WHOLE STRUCTURE IS OF EQUIVALENT STRENGTH TO THE UNPIERCED BULKHEAD AND WEATHERTIGHT WHEN CLOSED. DOOR LEADING OUTSIDE FROM DRY STORES WAS NOT WEATHERTIGHT.
ICLL I/12.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2018
Resolution: RINA class report submitted attesting to the rectification of the noted deficiency
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2018Resolved
CONSTRUCTION AND ARRANGEMENT OF SAUNAS SHALL COMPLY WITH PARAGRAPH 2.2.3.4. ELECTRICAL CASING IN SAUNA WAS BROKEN AND ALARM WAS IDENTIFIED AS INOPERABLE.
74 SOLAS (14) II-2/9.2.4.2.7
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2018
Resolution: RINA class report submitted attesting to the rectification of the noted deficiency
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 October 2018Resolved
WHERE "A" CLASS DIVISIONS ARE PENETRATED, SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. ETHERNET CABLE PENETRATIONS WERE IDENTIFIED IN THE CABLE TRUNK SPACES THROUGHOUT.
74 SOLAS (14) II-2/9.3.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2018
Resolution: RINA class report submitted attesting to the rectification of noted deficiency.