Records from 2016 to 2025. Most recent: inspection, 26 March 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)44.8 ft × 12.5 ft × 7.8 ft
Registered tonnagegross 17 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderABEKING & RASMUSSEN · LEMWERDER, GERMANY · built 1950
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWICKFORD, RI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 6 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
6 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 6
26 March 2025
Administrative Inspection · Inclining Experiment
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8104236
26 June 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7712931
13 November 2018
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6579930
26 October 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6291129
13 July 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6208176
22 September 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6000544
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 October 2017
No resolution recorded
Re-weld 03 stantions bases on STBD side.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 26 October 2017
No resolution recorded
Replace shaft packing gland for M/E.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 October 2017
No resolution recorded
Conduct underway drills under sail and main propulsion (Fire and Abandon ship)
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Not Operational
Issued 26 October 2017
No resolution recorded
Re-mount bilge high level alarm and test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › FCC SSL
Issued 22 September 2016
Resolved
Provide FCC station license.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Provided proof of valid FCC SSL document.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 September 2016
Resolved
Provide current FCC safety cert.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Provided proof of valid FCC SC.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 September 2016
Resolved
Provide current proof of Dapi enrollment.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Provided proof of enrollement in consortium for all three crew, and random testing completed in 2017. Vessel is in compliance with DAPI
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 September 2016
Resolved
Provide proper donning placard.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Vessel had donning placard viewable and current onboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 22 September 2016
Resolved
Provide current servicing for fixed and portable firefighting.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Vessel provided proof of service for all portable extinguishers on board and fixed CO2 system for engine compartment, 2017 completed by Fire Ex.
Communications › Radio Communications › EPIRB
Issued 22 September 2016
Resolved
Provide current NOAA registration sticker for EPIRB.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Vessel provided current NOAA registration sticker and document showing validity.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 22 September 2016
Resolved
Properly secure all lifelines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 23 September 2016
Resolution: All lifelines were checked an in good order, not worn and they were secured.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 September 2016
Resolved
Conduct underway fire and man overboard drills.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Cleared from existing CG-835, and added to current CG-835 for inspection conducted on 26OCT17.
Operations/Management › Vessel Activity › Underway
Issued 22 September 2016
Resolved
Conduct underway sail and propulsion tests.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Conducted dockside propulsion test, exercised fwd and aft propulsion, all sat minus shaft packing gland leaking excessively. CG-835 issued on 26OCT2017.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 22 September 2016
Resolved
Repair cracked stantion base for lifeline on STBD side at the boarding gate (forward side).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2016
Resolved 26 October 2017
Resolution: Stantions were re-welded and in good condition. Reciept was provided for work completed.