SPIRIT OF ALOHA

SPIRIT OF ALOHA is a 2005 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 2005, most recently in June 2026, along with 41 deficiencies and 3 casualty investigations between 2011 and 2021.

Records from 2005 to 2026. Most recent: inspection, 15 June 2026.

Built
2005
Last inspected
15 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF3743
789925
Flag
UNITED STATES
367443490
Maury page id
psix-789925

Inspections, by type

…with no type recorded5
Years with a record 21 calendar years (2005–2026)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 30.0 ft × 7.0 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX, VI, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 22 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF3743MMSI 367443490 · active · compulsorily equipped · granted 5 February 2020, expires 17 March 2030
WDC7812MMSI 367077380 · cancelled · compulsorily equipped · granted 18 November 2005, cancelled 22 March 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 40

15 June 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8405657
4 March 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8320177
15 April 2025 Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8050445
5 March 2025 Deficiency Check · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8089074
11 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7893934
27 February 2024 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855555
31 May 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7699957
12 April 2023 Internal Structural Exam · Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640403
26 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7438565
7 September 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7306931
8 June 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7225565
28 April 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7181595
12 March 2020 Administrative Inspection · DAPI Audit · In-Service Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6921541
23 February 2020 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6930269
8 October 2019 Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6831072
24 April 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6669025
21 June 2018 DAPI Audit · Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6452868
12 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6371958
3 October 2017 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6277468
21 September 2017 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 6272140
22 February 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6092249
27 September 2016 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 6010271
20 April 2016 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5858715
30 November 2015 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5772641
19 March 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4819362
23 February 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4258084
6 December 2011 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4202867
16 March 2010 COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3696869
4 December 2009 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3644753
3 December 2009 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3644426
3 December 2009 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3681263
2 April 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3444987
13 March 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3163821
5 December 2007 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3110912
16 April 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2912034
16 April 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2993053
5 March 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2906936
23 May 2006 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2656942
23 February 2006 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2817927
3 October 2005 Deadweight Survey · Construction Oversight · Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2508955

Deficiency record · 41

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2025 Resolved
Fire, abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Missing required drill entries from September 2024 to Feb 2025.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Stbd 1 & 4 bilge alarm lights are not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 9 May 2024
Resolution: Light was replaced and is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 April 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The two life floats onboard have punctures, no working waterlights, missing paddles and not secured to the weak link. Vessel rep must use [name withheld] approved material to conduct repairs, add working water lights, provide paddles and secure line to the weaklinK IAW regulations. Vessel route is reduce to limited coastwise, no more than 3 nm from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 9 May 2024
Resolution: All life floats are sat and meet the regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 30 adult life jackets are unserviceable, vessel rep must fix with [name withheld] approved material or replace and reapply CG approved retro tape. Total persons allowed reduce from 53 to 23. Vessel rep must present serviceable life jackets to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 29 April 2024
Resolution: Life jackets are now serviceable.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 May 2023 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. For a life float - Approved under approval series 160.027. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. The life float has small tears in the body which must be repaired IAW approved manufacturers [name withheld] material to OCMI satisfaction. The life float is not separated by spacers, must install spacers to meet the regulation. Vessel limited to not more than 3nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: All defs rectified same day.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 May 2023 Resolved
Life float should be stowed in a way that any protective covers will not interfere with launching and embarkation; the life floats have a large protective cover restricting the floats from floating free.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 31 May 2023
Resolution: Vessel rep removed the cover.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023 Resolved
An adult life jacket must be provided for each person carried onboard. Two adult life jackets were torn, OCMI. approved repair plan using manufacturer approved [name withheld] repair material. Reduced total persons to 51.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: Def cleared same day of inspection after the repair was made with approved material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 and Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Flexible nonmetallic hoses are not SAE J-1942 for generator fuel connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 30 May 2022
Resolution: SAE J-1942 hoses installed for the generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High level visual and audible alarms not working as designed.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 30 May 2022
Resolution: High level alarms operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicators are located behind the bar inside a wooden cabinet with a door not at the operating station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 30 May 2022
Resolution: Visual indicators installed at the control station.
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2016 Resolved
Provide updated navigation charts. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 2 May 2016
Resolution: Updated Navigation Charts were provided
Lifesaving › Lifefloat › Retroreflective Material
Issued 20 April 2016 Resolved
Replace retroreflective tape in lifefloats. 46 CFR 180.200
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 2 May 2016
Resolution: Retro-reflective tape was replaced on life floats.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 20 April 2016 Resolved
Provide first aid kit IAW 46 CFR 160.041(b)
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 28 April 2016
Resolution: Vessel rep provided picture of new USCG approved First Aid Kit IAW with 160.041
Fire Fighting › Fire Bucket › Quantity
Issued 20 April 2016 Resolved
Provide 03 fire buckets IAW 181.610.
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 28 April 2016
Resolution: Vessel rep provided pictures of fire buckets onboard the vessel.
Sail Rigging › Mast Step › Base
Issued 1 December 2015 Resolved
Mast is due to be unstepped during DDX. However, permission to delay mast unstepping has been granted until the end of December.
Action required: 705 - Other - as specified
Due 31 December 2015
Resolved 23 December 2015
Resolution: Mast was unstepped to meet the requirements of the DDX. All rigging from shrouds and stays were replaced to the satisfaction of MI.
Engineering › Sea-water System (primary cooling) › Valve
Issued 30 November 2015 Resolved
Replace all sea valves in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2015
Resolved 4 December 2015
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 30 November 2015 Resolved
Replace all shaft bearings in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2015
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 March 2014 Resolved
Stencil boat name and hailing port on 2 life rings.
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 2 April 2014
Resolution: Stenciled life rings.
Fire Fighting › Fire Bucket › Stenciling
Issued 19 March 2014 Resolved
Stencil fire buckets, add lanyards to fire buckets, replace fire buckets with 2 1/2 gallon buckets or drill holes at 2 1/2 gallon mark.
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 2 April 2014
Resolution: Stenciled fire buckets, added lanyards, drilled holes.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 March 2014 Resolved
Prove proper operation of port high water alarm unit.
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 2 April 2014
Resolution: Installed new unit which functions properly.
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 March 2010 Resolved
Provide up-to-date Coast Pilot, Tide/Current Tables. 46CFR184.420
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 March 2010 Resolved
Provide EAP Documentation, latest MIS report, and current alcohol testing equipement for DAPI audit. 46CFR16.401
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2010 Resolved
Renew waterlight batteries for lifefloats and lifering. 46CFR180.70
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Lifesaving › Lifefloat › Paddle
Issued 18 March 2010 Resolved
Provide two properly labeled oars per lifefloat.
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Construction/Loadline › Structures › Superstructure
Issued 18 March 2010 Resolved
Provide satisfactory rigging report from master to include rapaires to port forward mainstay chainplate(babystay), mainstay stern blcok, and full inspection (running rigging) as per rigging inspection regime/CID Note 13.
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Resolution: Master provide letter included in documents section of this activity.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 March 2010 Resolved
Prove proper operation of fireboy fire fighting system to satisfaction of USCG Inspector. 46CFR176.810
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Construction/Loadline › Structures › Deck Plating
Issued 16 March 2010 Resolved
Found hole in forward midships section of deck from bow ladder hoist, repair to prevent chaffing and restore original condition of deck.
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 March 2010 Resolved
Provide USCG Approved First Aid Kit. 46CFR184.710
Action required: 705 - Other - as specified
Due 8 April 2010
Resolved 1 April 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 April 2009 Resolved
Provide proof of annual servicing for portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2009
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 2 April 2009 Resolved
Provide proof of annual servicing for fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2009
Lifesaving › Hand Flares › Expired
Issued 2 April 2009 Resolved
Provide six additional red parachute flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 April 2009 Resolved
Provide first aid kit and label location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2009
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 2 April 2009 Resolved
Provide proof of DAPI Program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2010
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 April 2009 Resolved
Conduct Man Overboard and Fire drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2010
Engineering › Sea-water System (primary cooling) › Valve
Issued 5 December 2007 Resolved
Properly repair sea valves and make available for USCG Inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 December 2007
Resolution: New valves installed and observed in operation while vessel drydocked.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 December 2007 Resolved
Make tailshafts (2) available for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 December 2007
Resolution: Sighted tailshafts, propellers properly installed.
Construction/Loadline › Hull › Hull Plating
Issued 5 December 2007 Resolved
Make proper repair ot port daggerboard and make available for USCG Inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 December 2007
Resolution: Sighted properly repaired and installed port daggerboard.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 5 December 2007 Resolved
Make proper repairs to port strut and make available for USCG Inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 December 2007
Resolution: Sighted newly manufactured port strut properly installed.
Construction/Loadline › Hull › Bottom Plating
Issued 5 December 2007 Resolved
Make new installations of sewage holding tanks and beaching shoes available for USCG Inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 20 December 2007
Resolution: Sewage holding tanks and beaching shoes installed to inspector''s satisfaction.
Stability › Incline Test › General
Issued 23 February 2006 Resolved
Provide stability letter issued by the Coast Guard Marine Safety Center
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2006
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 23 February 2006 Resolved
Provide approval letter for revised #2 machinery drawing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2006

Casualty record · 3

17 April 2011Routine · role: Involved in a Marine Casualty · activity 3998294
23 February 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4258084
8 June 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7225565
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.