MAURY USCG vessel records Sign in
← All vessels

THOR

THOR is a 2004 freight ship. The Coast Guard has recorded 14 inspections since 2005, most recently in October 2020, along with 4 deficiencies and 3 operational controls.

Records from 2005 to 2020. Most recent: inspection, 7 October 2020.

Built
2004
Last inspected
7 October 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9291418 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
789986
Flag
MARSHALL ISLANDS
—
Maury page id
psix-789986

Inspections, by type

…with no type recorded5
Years with a record 7 calendar years (2005–2020)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it76831 - Dead Weight, Metric Ton
87174 - Displacement, Metric Ton
40060 - Convention (Subpart B), Gross Ton
25440 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

7 October 2020 ILO-147 Exam · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072647
5 August 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6765975
2 May 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6675211
16 October 2017 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6288289
21 August 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6244396
4 February 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5809699
3 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808514
5 January 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5787051
2 December 2010 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3899043
24 October 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2806884
23 February 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2590944
20 September 2005 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2494243
18 September 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2495404
14 September 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2492811

Deficiency record · 4

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2020 Resolved
Cylinders must always be secured and when not in use they must be stowed in a rack an in an upright position with the valve protection cap in place. Oxygen and acetylene were stored together in the acetylene room and not stowed properly. 46 CFR 147.60(b)(1)
Action required: 10 - Deficiency Rectified
Due 7 October 2020
Resolved 7 October 2020
Resolution: Ship's crew properly stored the oxygen and acetylene cyclinders.
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 21 August 2017 Resolved
2490- Personnel responsible for the operation of an incinerator installed in accordance with the requirements of paragraph 6.1 of this regulation shall be trained to implement the guidance provided in the manufacturers operating manual as required by paragraoh 7 of this regulation. 3 cracks were found at the corners of the lower door. (Continued in general info)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 October 2017
Resolution: Repaired and Corrected to the satisfaction of the attending Classification Representative.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 21 August 2017 Resolved
2120- Every ship shall carry a garbage management plan which the crew shall follow. The garbage plan is not being followed, mixed garbage was found throughout the ship, food mixed with other garbage, and paper was at found at the final collecion point prior to being discharged into the sea. Crew has disposed of waste overboard 14 times, which the PSCE believes included platics. Marpol V/10.2 -10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Resolution: Discussed with Captain, Chief Mate, and flag representative and issue resolved to the satisfaction of attending PSCO.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 21 August 2017 Resolved
2510- Vessel must maintain a ballast water management plan that has been specifically developed for the vessel and will allow those responsible for the plan to understand and follow it. Vessel currently does not document items in the ballast water management plan nor is a biofoulding management plan maintained. 33CFR151.2050(G) IMO MEPC Resolution207. 10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Resolution: Discussed with Captain, Chief Mate, and flag representative and issue resolved to the satisfaction of attending PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.