← All vessels
CLIPPER TOBAGO
CLIPPER TOBAGO is a tank ship. The Coast Guard has recorded 21 inspections since 2005, most recently in October 2010, along with 28 deficiencies — 1 with no resolution recorded — and 7 operational controls.
Records from 2005 to 2010. Most recent: inspection, 23 October 2010.
- Built
- Not recorded
- Last inspected
- 23 October 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 28 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9209001 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6VW9
790395
Flag
BAHAMAS, THE
—
Maury page id
psix-790395
Inspections, by type
…with no type recorded9
Years with a record
5 calendar years (2005–2010)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8834 - Dead Weight, Ton
2602 - Convention (Subpart B), Net Ton
2602 - Simplified, Net Ton
5483 - Convention (Subpart B), Gross Ton
5438 - Simplified, Gross Ton
2602 - Convention (Subpart B), Net Ton
2602 - Simplified, Net Ton
5483 - Convention (Subpart B), Gross Ton
5438 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
23 October 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876090
8 March 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3691572
3 February 2010
ISPS II Exam · COC-CHEM Renew · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3674555
3 February 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3674972
1 April 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3175331
27 March 2008
MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3172186
13 February 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146766
17 December 2007
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3121395
12 October 2007
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3078347
7 October 2007
PI Safety Exam · Deficiency Check · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3073021
19 May 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2934481
18 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2934181
18 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2952441
6 May 2007
ISM Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2923574
10 October 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2797598
22 September 2006
COC-CHEM Annual · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2784401
8 September 2006
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2772751
20 June 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2685959
7 January 2006
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2562737
24 November 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2540415
21 September 2005
COC-CHEM Renew · ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2498121
Deficiency record · 28
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 1 April 2008
Resolved
#1 cylinder fuel pump not providing adequate pressure to injector
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 March 2008
Resolved
make permanent repairs and provide properly operating OWSsystem including oil content meter & alarm. Provide class or Flag surveyor report to Coast Guard. 70a/b (Vessel may proceed to NPOC - Houston)
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 27 March 2008
Resolved
PRIOR TO DEPARTURE: Offload oily waste mixtures from bilge holding tank and sludge tank to approved reception facility. Current bilge holding tank content level is 10.4 cu. mtrs. make receipt of service available to Coast Guard. 17c
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 27 March 2008
Resolved
Make permanent repairs and provide properly operating ODME system. Provide class or Flag surveyor report to Coast Guard. 70 a/b.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 October 2007
Resolved
Transverse corrugated bulkhead fractured at tanktop, outboard most corrugation in way of cargo oil tanks no. 5 & 6. Correct to satisfaction of class and USCG Marine Inspector.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 7 October 2007
No resolution recorded
Failure to report major non-conformity to classification society. Vessel reported crack between cargo tanks 5S and 6S to operating operating company on September 22, 2007 prior to loading cargo. Operating company did not report non-conformity to classification society (ABS) until September 26, 2007, after cargo was discharged. Correct to the satisfaction of the administration.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 7 October 2007
Resolved
Port center vapor manifold missing pin.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 7 October 2007
Resolved
Sprinkler system for deck system, discharge heads blocked.
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 7 October 2007
Resolved
SMPEP inventory incomplete. 10 Boiler suits from box 1 and 300 sorbent pads from box 2 missing.
Lifesaving › Lifeboat Equipment › Oar
Issued 7 October 2007
Resolved
Conflicting vesel name on lifeboat oars.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 October 2007
Resolved
Oily water separator's oil content meter was found not functioning in accordance with operating manual. Correct to the satisfaction of class and attending USCG Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 7 October 2007
Resolved
Incinerator found to be inoperable due to damaged nozzle. Correct to satisfaction of attending class and USCG Marine Inspector.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 7 October 2007
Resolved
Original flag state endorsement for chief engineer's license not present on vessel.
Engineering › Diesel Engine (auxiliary) › Blower, Centrifugal
Issued 19 May 2007
Resolved
Vessel experienced a power irregularity.
Engineering › Bilge Water Management System › Piping
Issued 6 May 2007
Resolved
Vessel installed new OWS system during last dry dock 06Apr07. New piping is connected to sewage discharge pump. enabling vessel to take suction of the dirty oil tank with the sewage discharge pump. To the satisfaction of attending classification society surveyor.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 6 May 2007
Resolved
Vapor control lines on the vessel are not in accordance with 46 CFR 39.20-1
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 6 May 2007
Resolved
During review of vessel's cargo record book, it was determined that vessel is not complying with new MARPOL annex II regulations. Vessel is listing cargoes as A, B, C, D instead of X, Y, Z cargoes. Master was trained by Coast Guard on the new requirements for Annex II cargoes.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 6 May 2007
Resolved
Bilges in engine room had excessive amounts of oil, causing a potential fire hazard. Vessel must remove all oil from bilges. To satisfaction of attending classification society surveyor.
Documentation › Certificates/Documents › IOPP Certificate
Issued 6 May 2007
Resolved
Vessel does not have IOPP certificate on board. Vessel must provide valid IOPP certificate prior to departing the Port of Savannah. To the satisfaction of attending classification society surveyor.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 6 May 2007
Resolved
Cooling water supply line to the #2 generator has excessive water leaks. To the satisfaction of attending classification society surveyor.
Fire Fighting › Fire Main › Material
Issued 6 May 2007
Resolved
Water supply line for emergency fire pump running through the engine room is not properly insulated for fire protection. To the satisfaction of attending classification society surveyor.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 6 May 2007
Resolved
Deficiencies noted with vessel's Safety Management System. Appears to be a failure in ISM procedures. Vessel is required to have an external audit, prior to departure.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 6 May 2007
Resolved
Vessel's loadline does not reflect what is on certificate.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 6 May 2007
Resolved
Vessel to provide the Captain of the Port, a copy of the completed ISM report and any Flag recomendations prior to sailing.
Documentation › Logs/Records › Oil Record Book
Issued 6 May 2007
Resolved
Vessel only has machinery space oil record book (part 1) and cargo (part 2) for December 2006 thru present. Required to have oil record books going back three years, prior to return to US.
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 22 September 2006
Resolved
Pressure indication for vapor control system varies from cargo tank pressure readings. No calibration on record. System to be calibrated.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 22 September 2006
Resolved
Shipboard procedures do not include checking if required vapor detection equipment is on board.
Lifesaving › Launching Appliances › Davit
Issued 22 September 2006
Resolved
Limit switch for starboard side davit system for lifeboat is not working. Switch was tested while lifeboat was being recovered after abandon ship drill.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.