MAURY USCG vessel records Sign in
← All vessels

BOB MORRISON

BOB MORRISON is a 1980 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2005, most recently in May 2025, along with 45 deficiencies and 1 operational control.

Records from 2005 to 2025. Most recent: inspection, 12 May 2025.

Built
1980
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

791047
Flag
UNITED STATES
—
Maury page id
psix-791047

Inspections, by type

Years with a record 14 calendar years (2005–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)26.7 ft × 10.0 ft × 4.8 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS INC · SOMERSET, MA, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPERTH AMBOY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

12 May 2025 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8118652
2 July 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7964165
25 June 2024 Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7941966
31 May 2024 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7925105
9 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7710720
3 March 2023 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7644901
9 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7595637
12 May 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449257
21 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7202791
7 December 2020 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7107371
15 June 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6973844
31 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6699076
30 November 2018 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6589689
10 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6414687
18 May 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6148984
21 April 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6129511
17 May 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5879288
14 May 2012 Deficiency Check · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4310854
21 July 2008 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3274898
14 April 2008 Deficiency Check · Simplified Stability Test · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3183989
26 February 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3153699
18 September 2007 Annual Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3077495
20 September 2005 Internal Structural Exam · MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2497235

Deficiency record · 45

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 July 2024 Resolved
Repair rotted section of deck aft port section of the engine hatch.
Action required: 705 - Other - as specified
Resolved 3 December 2024
Resolution: Prior to credit drydock
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 July 2024 Resolved
Repair engine latch hatch forward starboard side of the engine hatch cover.
Action required: 705 - Other - as specified
Resolved 3 December 2024
Resolution: Prior to credit drydock
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 May 2021 Resolved
Leaking stern shaft stuffing tube bearing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: Complete
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 May 2019 Resolved
Boundaries that separate machinery spaces from accomodation spaces must be lined with noncombustible panels or insulations. Vessel's engine room compartment was not insulated. 46 CFR 177.410(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 11 June 2019
Resolution: Recieved photo of new insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019 Resolved
At least one lifebuoy must be fitted with a 60ft lifeline. Vessel's lifebuoy only had 50ft lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 31 May 2019
Resolution: Received picture of new lifeline
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2019 Resolved
Vessel not having power driven fire pump must have at least three 2.5 gal buckets. One of fire buckets was cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 31 May 2019
Resolution: Recieve picture of new fire bucket.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 May 2017 Resolved
Drills need to be conducted monthly and recorded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 26 May 2017
Resolution: Received photos of drills recorded in logbook.
Lifesaving › Hand Flares › Expired
Issued 18 May 2017 Resolved
Replace 2 day or night hand flares.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 26 May 2017
Resolution: Received photos of 2 replacement flares.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 May 2016 Resolved
HATCH COVERS MUST BE ATTACHED BY HINGES, CAPTIVE CHAINS OR OTHER DEVICES OF SUBSTANTIAL STRENGTH TO PREVENT ITS LOSS
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Attached cover with cable.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2016 Resolved
PROVIDE NEW FIRST AID KIT
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Resolution: Provided new first aid kit.
Lifesaving › Hand Flares › Quantity
Issued 17 May 2016 Resolved
PROVIDE 02 ADDITIONAL ORANGE OR RED FLARES
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Resolution: Provided 02 new flares.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2016 Resolved
POST COI IN LOCATION VISIBLE TO PASSENGERS
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Resolution: Posted COI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2016 Resolved
FIX PORT RUNNING LIGHT
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 17 May 2016
Resolution: REMEDIED ON THE SPOT
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 May 2012 Resolved
Provide verification of enrollment of all launch captains in Drug and Alcohol testing program. PTCP for all unenrolled captains.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2012
Resolution: Attended vessel, the company provided documentation from Maritime Consortium Inc demonstrating all crewmembers are enrolled in the consortium.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 May 2012 Resolved
Vessel did not receive 2011 annual inspection. Vessel must receive new COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2012
Resolution: Conducted COI Inspection on 21May2012.
Engineering › Bilge Water Management System › Not Operational
Issued 14 May 2012 Resolved
Prove proper operation of bilge pump and bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2012
Resolution: Attended vessel, proper operation of the bilge pump and alarm was demonstrated at the time of inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2012 Resolved
Remove or properly secure dead-end wiring in fwd cabin space.
Due 4 June 2012
Resolved 25 May 2012
Resolution: Attended vessel the dead end wire in the fwd cabin space was secured at the time of inspection.
Lifesaving › Hand Flares › Not on Board
Issued 14 May 2012 Resolved
Vessel is missing two of six flares. Vessel is restricted to trips not more than 30 minutes until six flares are on board.
Due 4 June 2012
Resolved 25 May 2012
Resolution: Attended vessel, six flares were onboard at the time.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 July 2008 Resolved
Provide valid/original COD onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: Original COD was onboard vessel.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 July 2008 Resolved
Provide seven additional Adult Type I PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: All Adult PFD''s were onboard.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 July 2008 Resolved
Replace retroreflective tape in way of sixteen adult PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: Retroreflective tape was satisfactory on all new PFDs.
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 21 July 2008 Resolved
Prove proper operation of main propulsion engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: New main propulsion engine operated satisfactorily.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 July 2008 Resolved
Prove proper operation of stern navigation light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: Stern navigation light worked satisfactorily.
Stability › Watertight Integrity › General
Issued 21 July 2008 Resolved
Repair handle in way of stern hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: Stern hatch handle was replaced.
Stability › Watertight Integrity › General
Issued 21 July 2008 Resolved
Provide gasket in way of stern deck hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: Stern deck hatch gasket was replaced.
Communications › Alarms/Indicators › Fire Alarm
Issued 21 July 2008 Resolved
Prove proper operation of alarms and shutdowns in way fixed fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: Proper operation of Fire Boy system was demonstrated.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2008 Resolved
Provide letter to OCMI requesting replacement COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2010
Resolution: New COI will be provided once PTCP deficiencies are cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2008 Resolved
Provide first aid kit onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 April 2008 Resolved
Prove satisfactory service of vessels fixed and portable fire extinguishing system, prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2008
Stability › Incline Test › General
Issued 14 April 2008 Resolved
Conduct simplified stability test in presence of Marine Inspector prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 September 2007 Resolved
Make repairs to the boarding ladder.
Due 18 October 2007
Resolved 10 October 2007
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 18 September 2007 Resolved
Provide covers for batteries.
Due 18 October 2007
Resolved 10 October 2007
Engineering › Fuel Oil Service System › Hose
Issued 18 September 2007 Resolved
Double clamp all fuel lines.
Due 18 October 2007
Resolved 10 October 2007
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 18 September 2007 Resolved
Provide information regarding engine refit.
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 23 May 2008
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 September 2007 Resolved
Replace raw water engine cooling valve.
Due 18 October 2007
Resolved 10 October 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 18 September 2007 Resolved
Provide covers in way of engine room vents.
Action required: 705 - Other - as specified
Due 18 October 2007
Resolved 23 May 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 September 2007 Resolved
Secure steering space hatch with a lanyard.
Due 18 October 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Bracket
Issued 2 August 2005 Resolved
Repair broken rub rail on p/s aft.
Due 12 September 2005
Resolved 12 September 2005
Resolution: Broken rub rail replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 2 August 2005 Resolved
Repair cracked/split wood on p/s/ fwd.
Due 12 September 2005
Resolved 12 September 2005
Resolution: Replaced with new.
Construction/Loadline › Structures › Manhole
Issued 2 August 2005 Resolved
Provide captive device on hatch to steering gear compartment.
Due 12 August 2005
Resolved 12 August 2005
Resolution: Chain placed on hatch cover, to steering gear compartment.
Lifesaving › Lifebuoys › Stowage
Issued 2 August 2005 Resolved
Properly stow ring life buoy.
Due 12 September 2005
Resolved 12 September 2005
Resolution: Ring lifebuoy properly stowed.
Fire Fighting › Fire Bucket › Quantity
Issued 2 August 2005 Resolved
Provide (1) 2.5 gallon fire bucket.
Due 12 September 2005
Resolved 12 September 2005
Resolution: Vsl rep provided (1) 2.5 gallon fire bucket.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 August 2005 Resolved
Conduct MOB drill.
Due 12 September 2005
Resolved 12 September 2005
Resolution: Sat MOB drill conducted.
Engineering › Steering Gear System › Linkage
Issued 2 August 2005 Resolved
Repair limit switch/chain in steering gear compartment.
Due 12 October 2005
Resolved 12 October 2005
Resolution: Limit switch repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 August 2005 Resolved
Properly terminate/remove dead end wires in e/r.
Due 12 September 2005
Resolved 12 September 2005
Resolution: Dead end wires terminated.

Ownership record